CoChat

LC-MS/MS method validation for determination of selected neonicotinoids in groundwater for the purpose of a column experiment

Pietrzak, Damian, Wątor, Katarzyna, Pękała, Dorota, Wójcik, Justyna, Chochorek, Aneta, Kmiecik, Ewa, Kania, Jarosław · 2019 · Journal of Environmental Science and Health, Part B

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

Abstract

The work was carried out to develop and validate a method based on liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous detection and quantification of five neonicotinoid insecticides: acetamiprid, clothianidin, imidacloprid, thiacloprid and thiamethoxam in groundwater samples for the purpose of a further column experiment. This experiment will be used to analyze breakthrough curves of neonicotinoids under a saturated water flow to set transport parameters, where the reliability of the results of chemical analysis plays an important role. The validation was performed in a concentration range from 0.09 µg L−1 to 100 µg L−1 using an Infinity 1290 (Agilent, USA) chromatograph coupled with a QTrap 5500 mass spectrometer (Sciex, Canada). The calibration curves were obtained on the basis of the results of six standard solution analyses. Linearity was not lower than 0.998. The limit of detection was set at the lowest concentration which can be determined with an acceptable accuracy and precision. All pesticides had recoveries in the range 85–109% with relative standard deviation values less than 8.1%. The estimated measurement uncertainty did not exceed 30%, so the LC-MS/MS method fits for the intended purpose.

Overview

Integrity signals

Registry

Crossref · 10.1080/03601234.2019.1574173

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 43 references

Research works printed but not linked: 3

  1. Pietrzak D., 2018, Clean – Soil Air Water
  2. Ellison, S. L. R.; Williams, A., Eds. Eurachem/CITAC Guide: Quantifying Uncertainty in Analytical Measurement, 3rd Ed. Teddington, UK: LGC (Teddington) Limited; 2012; pp. 1–126.
  3. EC, 1998, Off. J. Eur. Commun, 330, 1

Metadata

Authors
Pietrzak, D., Wątor, K., Pękała, D., Wójcik, J., Chochorek, A., Kmiecik, E., & Kania, J.
Affiliations
  • AGH University of Krakow (PL)
  • Wessling Polska, Kraków, Poland
Corresponding author
Kmiecik, Ewa
Venue
Journal of Environmental Science and Health, Part B
Published
2019-03
Volume
54
Issue
5
Pages
424-431
ISSN
  • 0360-1234 (ISSN-L)
  • 1532-4109
OpenAlex
W2919886104
Cited by
19
References
43
Citations by year
2026: 1 · 2025: 4 · 2023: 3 · 2022: 6 · 2021: 2 · 2020: 2 · 2019: 1
FWCI
2.12
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Environmental Science and Health Part B (publishedVersion)
  • PubMed (publishedVersion)
Funders
AGH-UST (11.11.140.797, 15.11.140.210)
Topics
  • Life Sciences › Agricultural and Biological Sciences › Food Science › Pesticide Residue Analysis and Safety
  • Physical Sciences › Environmental Science › Pollution › Pesticide and Herbicide Environmental Studies
  • Physical Sciences › Chemistry › Analytical Chemistry › Analytical Methods in Pharmaceuticals
Keywords
neonicotinoids, groundwater contamination, acetamiprid, clothianidin, imidacloprid, thiacloprid, thiamethoxam, pesticide analysis, method validation, column experiments, breakthrough curves, pesticide transport
MeSH terms
Neonicotinoids, Calibration, Chromatography, Liquid, Gas Chromatography-Mass Spectrometry, Pesticides, Soil Pollutants, Water Pollutants, Chemical, Reproducibility of Results, Tandem Mass Spectrometry, Limit of Detection, Groundwater

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: LC-MS/MS method validation for determination of selected neonicotinoids in groundwater for the purpose of a column experiment. https://app.cochat.ai/papers/10.1080/03601234.2019.1574173
The paper
Pietrzak, D., Wątor, K., Pękała, D., Wójcik, J., Chochorek, A., Kmiecik, E., & Kania, J. (2019). LC-MS/MS method validation for determination of selected neonicotinoids in groundwater for the purpose of a column experiment. Journal of Environmental Science and Health, Part B. https://doi.org/10.1080/03601234.2019.1574173

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.