The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Recent Developments in Ion Mobility Spectrometry
Abstract
The general principles and technical implementations of traditional time-of-flight ion mobility spectrometers and analyzers with field-dependent mobilities were reviewed in our last article in this journal. Recent advances in instrumentation and new applications since 2006 are highlighted in this review. In addition to traditional applications as military chemical-agent detectors, ion mobility techniques have become popular for different purposes. Though ion mobility spectrometry was solely used as vapor sensor in the past decades, further developments in ionization techniques (especially electrospray ionization) now permit its routine use for the analysis of liquid samples. The coupling of ion mobility spectrometry with selective sample preparation techniques such as molecular-imprinted polymers, coupling with chromatographic techniques, the use of dopants, and application of selective ionization sources has led to an expanded number of applications in industrial and environmental analysis with complex sample matrices due to an improved selectivity in comparison with traditional stand-alone spectrometers. Furthermore, new developments in hyphenated techniques, especially ion mobility–mass spectrometry couplings, has resulted in an increased number of new applications for the analysis of biomolecules and pharmaceutical samples and in clinical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Cited by
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
Ion Mobility Mass Spectrometry of Peptide Ions: Effects of Drift Gas and Calibration Strategies
Bush, M. F., Campuzano, I. D. G., & Robinson, C. V. (2012) · Analytical Chemistry · doi:10.1021/ac3014498 · Cited by 315
A review on advances in application of polyaniline for ammonia detection
Tanguy, N. R., Thompson, M., & Yan, N. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.11.008 · Cited by 284
Metadata
- Authors
- Borsdorf, H., Mayer, T., Zarejousheghani, M., & Eiceman, G. A.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2011-08
- Volume
- 46
- Issue
- 6
- Pages
- 472-521
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W2087393239
- Cited by
- 188
- References
- 1
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Recent Developments in Ion Mobility Spectrometry. https://app.cochat.ai/papers/10.1080/05704928.2011.582658
- The paper
- Borsdorf, H., Mayer, T., Zarejousheghani, M., & Eiceman, G. A. (2011). Recent Developments in Ion Mobility Spectrometry. Applied Spectroscopy Reviews. https://doi.org/10.1080/05704928.2011.582658
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.