Recent Developments in Ion Mobility Spectrometry
The DOI matches its Crossref record; 164 of the 164 references it cites were found in a registry or an index.
Abstract
The general principles and technical implementations of traditional time-of-flight ion mobility spectrometers and analyzers with field-dependent mobilities were reviewed in our last article in this journal. Recent advances in instrumentation and new applications since 2006 are highlighted in this review. In addition to traditional applications as military chemical-agent detectors, ion mobility techniques have become popular for different purposes. Though ion mobility spectrometry was solely used as vapor sensor in the past decades, further developments in ionization techniques (especially electrospray ionization) now permit its routine use for the analysis of liquid samples. The coupling of ion mobility spectrometry with selective sample preparation techniques such as molecular-imprinted polymers, coupling with chromatographic techniques, the use of dopants, and application of selective ionization sources has led to an expanded number of applications in industrial and environmental analysis with complex sample matrices due to an improved selectivity in comparison with traditional stand-alone spectrometers. Furthermore, new developments in hyphenated techniques, especially ion mobility–mass spectrometry couplings, has resulted in an increased number of new applications for the analysis of biomolecules and pharmaceutical samples and in clinical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634 · cited 1×
“(194) in 1968 that culminated with mass spectrometry studies of Yamashita and Fenn (195) and finally for the analysis of biological macromolecules (196).”
BackgroundMass Spectrometry Sampling Under Ambient Conditions with Desorption Electrospray Ionization
Takáts, Z., Wiseman, J. M., Gologan, B., & Cooks, R. G. (2004) · Science · doi:10.1126/science.1104404 · Cited by 3,324 · cited 1×
“First described in 2004 (202), DESI was added to IMS-MS first in 2005 (203) and offers direct access to the composition of the surface because an ESI is directed to a surface where charged droplets lead to secondary ions derived from the sample.”
BackgroundAnalytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868 · cited 1×
“In 1996, they reported a nanoelectrospray ion source (199) with a 1- to 2-μm orifice, flow rate of ∼20 nL min−1, and small-size droplet diameters less than 200 nm without liquid pumps.”
BackgroundDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613 · cited 1×
“(194) in 1968 that culminated with mass spectrometry studies of Yamashita and Fenn (195) and finally for the analysis of biological macromolecules (196).”
BackgroundIon mobility–mass spectrometry
Kanu, A. B., Dwivedi, P., Tam, M., Matz, L., & Hill, H. H. (2008) · Journal of Mass Spectrometry · doi:10.1002/jms.1383 · Cited by 1,154
Ion mobility–mass spectrometry analysis of large protein complexes
Ruotolo, B. T., Benesch, J. L. P., Sandercock, A. M., Hyung, S.-J., & Robinson, C. V. (2008) · Nature Protocols · doi:10.1038/nprot.2008.78 · Cited by 1,092 · cited 1×
“(265) described a protocol for data collection and interpretation of large protein complexes by IMMS.”
BackgroundElectrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974 · cited 1×
“Wilm and Mann introduced another micro-ESI (198) with droplet sizes at 200 nm or below and flow rates <25 nL min−1 using a gold-coated borosilicate glass capillary with an orifice of 1–3 μm.”
MethodPringle, S. D., Giles, K., Wildgoose, J. L., Williams, J. P., Slade, S. E., Thalassinos, K., Bateman, R. H., Bowers, M. T., & Scrivens, J. H. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.07.021 · Cited by 808
Applications of a travelling wave‐based radio‐frequency‐only stacked ring ion guide
Giles, K., Pringle, S. D., Worthington, K. R., Little, D., Wildgoose, J. L., & Bateman, R. H. (2004) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1641 · Cited by 727 · cited 2×
“SRIGs are another type of ion guide that includes a series of planar electrodes orthogonally arranged to a specified axis that have been used and developed since 1969 (180).”
BackgroundMethodNegative ion production with the electrospray ion source
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a046 · Cited by 581 · cited 2×
“The variety of ESI sources with IMMS is great (Tables 6 and 7) and can be referenced to mobility studies of Dole et al. (194) in 1968 that culminated with mass spectrometry studies of Yamashita and Fenn (195) and finally for the analysis of biological macromolecules (196).”
Background
Cited by
Review on ion mobility spectrometry. Part 1: current instrumentation
Cumeras, R., Figueras, E., Davis, C. E., Baumbach, J. I., & Gràcia, I. (2015) · The Analyst · doi:10.1039/c4an01100g · Cited by 459
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Recent developments in liquid chromatography–mass spectrometry and related techniques
Holčapek, M., Jirásko, R., & Lísa, M. (2012) · Journal of Chromatography A · doi:10.1016/j.chroma.2012.08.072 · Cited by 330
Ion Mobility Mass Spectrometry of Peptide Ions: Effects of Drift Gas and Calibration Strategies
Bush, M. F., Campuzano, I. D. G., & Robinson, C. V. (2012) · Analytical Chemistry · doi:10.1021/ac3014498 · Cited by 315
A review on advances in application of polyaniline for ammonia detection
Tanguy, N. R., Thompson, M., & Yan, N. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.11.008 · Cited by 284
Schneider, B. B., Nazarov, E. G., Londry, F., Vouros, P., & Covey, T. R. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21453 · Cited by 195
Metadata
- Authors
- Borsdorf, H., Mayer, T., Zarejousheghani, M., & Eiceman, G. A.
- Venue
- Applied Spectroscopy Reviews
- Publisher
- Informa UK Limited
- Published
- 2011-08
- Volume
- 46
- Issue
- 6
- Pages
- 472-521
- ISSN
- 0570-4928 (ISSN-L)
- 1520-569X
- OpenAlex
- W2087393239
- Cited by
- 188
- References
- 164
- FWCI
- 8.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.