The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Bioelectrical Impedance Analysis: A Review of Principles and Applications
Abstract
Whole-body bioelectrical impedance analysis (BIA) is widely used by researchers and clinicians as a noninvasive and safe method to estimate body composition and body water volume in children and adults. Development of new approaches, such as segmental and multifrequency analyzers, should greatly expand the utility of this electrical technique. This article reviews the principles, underlying assumptions, clinical applications and future directions of the BIA method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,112
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370
Lean body mass estimation by bioelectrical impedance analysis: a four-site cross-validation study
Segal, K., Van Loan, M., Fitzgerald, P., Hodgdon, A., & Van Itallie, T. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/47.1.7 · Cited by 881
Estimation of total body water by bioelectrical impedance analysis
Kushner, R., & Schoeller, D. (1986) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/44.3.417 · Cited by 772
Self-citationThe Body Cell Mass and Its Supporting Environment
Bouman, H. D. (1963) · Physical Therapy · doi:10.1093/ptj/43.9.695a · Cited by 625
Correlation of whole-body impedance with total body water volume.
Hoffer, E. C., Meador, C. K., & Simpson, D. C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.4.531 · Cited by 525
Bioelectric impedance phase angle and body composition
Baumgartner, R., Chumlea, W., & Roche, A. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.1.16 · Cited by 477
Estimation of human body composition by electrical impedance methods: a comparative study
Segal, K. R., Gutin, B., Presta, E., Wang, J., & Van Itallie, T. B. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.58.5.1565 · Cited by 464
Relationship between total body water and surface area in normal and obese subjects
Hume, R., & Weyers, E. (1971) · Journal of Clinical Pathology · doi:10.1136/jcp.24.3.234 · Cited by 377
Research works printed but not linked: 29
- Thomasett A, 1962, Lyon Med, 207, 107
- Fuller NJ, 1989, Eur J Clin Nutr, 43, 779
- Lukaski HC, 1987, “In Vivo Body Composition Studies.”, 410
- Deurenberg P, 1988, Eur J Clin Nutr, 42, 1017
- Van Loan M, 1987, Hum Biol, 59, 299
- Deurenberg P, 1989, Eur J Clin Nutr, 43, 885
- Diaz EO, 1989, Eur J Clin Nutr, 43, 129
- Heitmann BL, 1990, Int J Obes, 14, 789
- Deurenberg P, 1991, Int J Obes, 15, 17
- Deurenberg P, 1989, Eur J Clin Nutr, 43, 623
- Deurenberg P, 1990, Eur J Clin Nutr, 44, 261
- Helenius MYT, 1987, Hum Biol, 59, 271
- Guo S, 1987, Hum Biol, 59, 221
- Baumgartner RN, 1987, Hum Biol, 59, 235
- Kushner RF, 1988, Eur J Clin Nutr, 42, 101
- Meguid MM, 1988, Nutrition, 4, 363
- Böhm D, 1990, Infusiontherapie, 17, 75
- Segal KR, 1987, Fed Proc, 46, 1334
- McDougall D, 1986, Surgical Forum, 37, 42
- Kanai H, 1987, Med ProgTechnol, 12, 159
- Jenin P, 1975, Aviat Space Environ Med, 46, 152
- Espejo MGA, 1989, Crit Care Med, 17, 360, 10.1097/00003246-198904000-00012 · doi:10.1097/00003246-198904000-00012
- Tedner B, 1983, Med Biol Eng Comput, 21, 285, 10.1007/BF02478495 · doi:10.1007/bf02478495
- Tedner BT, 1984, Acute Care, 10, 200
- Tedner B, 1985, Artif Organs, 9, 416, 10.1111/j.1525-1594.1985.tb04403.x · doi:10.1111/j.1525-1594.1985.tb04403.x
- Fredrix EWHM, 1990, Eur J Clin Nutr, 44, 749
- Souweine G, 1981, J Neurol, 226, 199, 10.1007/BF00313382 · doi:10.1007/bf00313382
- Cardus D, 1988, Arch Phys Med Rehabil, 69, 186
- Watanabe R, 1989, Lymphology, 22, 85
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
A new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
Piccoli, A., Rossi, B., Pillon, L., & Bucciante, G. (1994) · Kidney International · doi:10.1038/ki.1994.305 · Cited by 711
Metabolic equivalent: one size does not fit all
Byrne, N. M., Hills, A. P., Hunter, G. R., Weinsier, R. L., & Schutz, Y. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00023.2004 · Cited by 527
Kotler, D., Burastero, S., Wang, J., & Pierson, R. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.489s · Cited by 472
Human Body Composition and the Epidemiology of Chronic Disease
Baumgartner, R. N., Heymsfield, S. B., & Roche, A. F. (1995) · Obesity Research · doi:10.1002/j.1550-8528.1995.tb00124.x · Cited by 413
Metadata
- Authors
- Kushner, R. F.
- Venue
- Journal of the American College of Nutrition
- Publisher
- Informa UK Limited
- Published
- 1992-04-01
- Volume
- 11
- Issue
- 2
- Pages
- 199-209
- ISSN
- 0731-5724 (ISSN-L)
- 1541-1087
- OpenAlex
- W176759912
- Cited by
- 625
- References
- 58
- FWCI
- 4.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioelectrical Impedance Analysis: A Review of Principles and Applications. https://app.cochat.ai/papers/10.1080/07315724.1992.12098245
- The paper
- Kushner, R. F. (1992). Bioelectrical Impedance Analysis: A Review of Principles and Applications. Journal of the American College of Nutrition. https://doi.org/10.1080/07315724.1992.12098245
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.