Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 970

The DOI matches its Crossref record.

Calcium Absorption Varies within the Reference Range for Serum 25-Hydroxyvitamin D

Heaney, Robert P., Dowell, M. Susan, Hale, Cecilia A., Bendich, Adrianne·2003·Journal of the American College of Nutrition

Abstract

BACKGROUND: Calcium absorption is generally considered to be impaired under conditions of vitamin D deficiency, but the vitamin D status that fully normalizes absorption is not known for humans. OBJECTIVE: To quantify calcium absorption at two levels of vitamin D repletion, using pharmacokinetic methods and commercially marketed calcium supplements. DESIGN: Two experiments performed in the spring of the year, one year apart. In the first, in which participants were pretreated with 25-hydroxyvitamin D (25OHD), mean serum 25OHD concentration was 86.5 nmol/L; and in the other, with no pretreatment, mean serum concentration was 50.2 nmol/L. Participants received 500 mg oral calcium loads as a part of a standard low calcium breakfast. A low calcium lunch was provided at mid-day. Blood was obtained fasting and at frequent intervals for 10 to 12 hours thereafter. METHODS: Relative calcium absorption at the two 25OHD concentrations was estimated from the area under the curve (AUC) for the load-induced increment in serum total calcium. RESULTS: AUC(9) (+/- SEM), was 3.63 mg hr/dL +/- 0.234 in participants pretreated with 25OHD and 2.20 +/- 0.240 in those not pretreated (P < 0.001). In brief, absorption was 65% higher at serum 25OHD levels averaging 86.5 nmol/L than at levels averaging 50 nmol/L (both values within the nominal reference range for this analyte). CONCLUSIONS: Despite the fact that the mean serum 25OHD level in the experiment without supplementation was within the current reference ranges, calcium absorptive performance at 50 nmol/L was significantly reduced relative to that at a mean 25OHD level of 86 nmol/L. Thus, individuals with serum 25-hydroxyvitamin D levels at the low end of the current reference ranges may not be getting the full benefit from their calcium intake. We conclude that the lower end of the current reference range is set too low.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/07315724.2003.10719287

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 970

Metadata

Authors
Heaney, R. P., Dowell, M. S., Hale, C. A., & Bendich, A.
Venue
Journal of the American College of Nutrition
Published
2003-04
Volume
22
Issue
2
Pages
142-146
ISSN
  • 0731-5724 (ISSN-L)
  • 1541-1087
OpenAlex
W1996563641
Cited by
970
References
0
FWCI
26.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Calcium Absorption Varies within the Reference Range for Serum 25-Hydroxyvitamin D. https://app.cochat.ai/papers/10.1080/07315724.2003.10719287
The paper
Heaney, R. P., Dowell, M. S., Hale, C. A., & Bendich, A. (2003). Calcium Absorption Varies within the Reference Range for Serum 25-Hydroxyvitamin D. Journal of the American College of Nutrition. https://doi.org/10.1080/07315724.2003.10719287

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.