CoChat

Extraction of Copper(II) by CYANEX 302 in Kerosene from Different Aqueous Media

El‐Hefny, N. E., Daoud, J. A. · 2007 · Solvent Extraction and Ion Exchange

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

The solvent extraction of Cu(II) with CYANEX 302 (bis(2,4,4‐trimethylpentyl) monothiophosphinic acid) in kerosene from different aqueous solutions including sulphate, chloride, and nitrate media has been systematically investigated. The effect of various parameters such as the time of equilibration, pH, the extractant and metal concentrations, the temperature, as well as the effect of anions on the extraction process has been studied. An equilibrium equation is proposed assuming that copper was first extracted as Cu2+ followed by reduction of to Cu+ while the CYANEX 302 extractant is correspondingly oxidized. The thermodynamic parameters, free energy (ΔG), enthalpy (ΔH), and entropy (ΔS), have been calculated. The stripping of Cu(II) from loaded organic solutions by using different stripping agents showed that effective stripping is obtained upon using high concentration of nitric acid which oxidizes the extracted Cu(I) to Cu(II).

Overview

Integrity signals

Registry

Crossref · 10.1080/07366290701634172

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Research works printed but not linked: 3

  1. Fucheng, H. 1996. The study of Separation of Copper and Zinc in Ammoniacal Solution by Solvent Extraction with LIX 84.Proceedings of International Solvent Extraction Conference (ISEC'96). March19–231996, Melbourne, Australia. Vol. 1, pp.727
  2. Chimenos, J. M., Fernandez, M. A., Segarra, M., Fernandez, A. I., Esparducer, A. and Espiell, F. 1999. Extraction of Copper contained in ammonia solutions from the Electronics Industry with LIX 84.Proceedings of International Solvent Extraction Conference (ISEC'99). March19–231999, Barcelona, Spain. pp.759
  3. Cote, G., Martin, J. V., Bauer, D. and Mottot, Y. 2002.Proceedings of International Solvent Extraction Conference (ISEC' 2002). March18–212002, Cape Town, South Africa. Vol. 1, pp.291

Cited by

See all 25

Metadata

Authors
El‐Hefny, N. E., & Daoud, J. A.
Affiliations
Egyptian Atomic Energy Authority (EG)
Venue
Solvent Extraction and Ion Exchange
Published
2007-10
Volume
25
Issue
6
Pages
831-843
ISSN
  • 0736-6299 (ISSN-L)
  • 1532-2262
OpenAlex
W1978100674
Cited by
25
References
18
Citations by year
2025: 1 · 2024: 2 · 2023: 1 · 2022: 1 · 2021: 5 · 2020: 4 · 2018: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 2 · 2012: 2
FWCI
1.53
Type
journal article
Language
en
Open access
closed
Locations
Solvent Extraction and Ion Exchange (publishedVersion)
Topics
  • Physical Sciences › Materials Science › Metals and Alloys › Extraction and Separation Processes
  • Physical Sciences › Chemical Engineering › Filtration and Separation › Chemical and Physical Properties in Aqueous Solutions
  • Physical Sciences › Chemistry › Inorganic Chemistry › Radioactive element chemistry and processing
Keywords
copper(II) extraction, Cyanex 302, kerosene, solvent extraction, chloride media, nitrate media, anion effects, extraction equilibrium, thermodynamic parameters, copper(I) reduction, copper stripping, nitric acid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.