How well does a commercially available wearable device measure sleep in young athletes?
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The validity of a commercially available wearable device for measuring total sleep time was examined in a sample of well-trained young athletes during night-time sleep periods and daytime naps. Participants wore a FitBit HR Charge on their non-dominant wrist and had electrodes attached to their face and scalp to enable polysomnographic recordings of sleep in the laboratory. The FitBit automatically detected 24/30 night-time sleep periods but only 6/20 daytime naps. Compared with polysomnography, the FitBit overestimated total sleep time by an average of 52 ± 152 min for night-time sleep periods, and by 4 ± 8 min for daytime naps. It is important for athletes and practitioners to be aware of the limitations of wearable devices that automatically detect sleep duration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agreement Between Methods of Measurement with Multiple Observations Per Individual
Bland, J. M., & Altman, D. G. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701329422 · Cited by 2,065
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301 · cited 1×
“Like most accelerometer-based devices (Kosmadopoulos et al. 2014; Montgomery-Downs et al. 2012; Zambotti et al. 2015), the device in this study overestimated TST compared with PSG.”
MethodEvidence of disturbed sleep and increased illness in overreached endurance athletes
HAUSSWIRTH, C., LOUIS, J., AUBRY, A., BONNET, G., DUFFIELD, R., & LE MEUR, Y. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000177 · Cited by 236 · cited 2×
“2014), and it can be used as a lead indicator of training stress (Hausswirth et al. 2014).”
BackgroundAlternatives to polysomnography (PSG): a validation of wrist actigraphy and a partial-PSG system
Kosmadopoulos, A., Sargent, C., Darwent, D., Zhou, X., & Roach, G. D. (2014) · Behavior Research Methods · doi:10.3758/s13428-013-0438-7 · Cited by 160
Self-citation
Cited by
Sleep and the athlete: narrative review and 2021 expert consensus recommendations
Walsh, N. P., Halson, S. L., Sargent, C., Roach, G. D., Nédélec, M., Gupta, L., Leeder, J., Fullagar, H. H., Coutts, A. J., Edwards, B. J., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-102025 · Cited by 571
Self-citationWearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Accuracy of Wristband Fitbit Models in Assessing Sleep: Systematic Review and Meta-Analysis
Haghayegh, S., Khoshnevis, S., Smolensky, M. H., Diller, K. R., & Castriotta, R. J. (2019) · Journal of Medical Internet Research · doi:10.2196/16273 · Cited by 446
“%) relied on PSG as reference to evaluate Fitbit performance [22,25-28, 30, 31, 37-42 37-42 ] ; the other 9 ( 41”
Miller, D. J., Sargent, C., & Roach, G. D. (2022) · Sensors · doi:10.3390/s22166317 · Cited by 328
Self-citationSleep and Athletic Performance
Charest, J., & Grandner, M. A. (2020) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2019.11.005 · Cited by 264
Metadata
- Authors
- Sargent, C., Lastella, M., Romyn, G., Versey, N., Miller, D. J., & Roach, G. D.
- Venue
- Chronobiology International
- Publisher
- Informa UK Limited
- Published
- 2018-05-11
- Volume
- 35
- Issue
- 6
- Pages
- 754-758
- ISSN
- 0742-0528 (ISSN-L)
- 1525-6073
- OpenAlex
- W2802906415
- Cited by
- 45
- References
- 4
- FWCI
- 6.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.