Wearable Sleep Technology in Clinical and Research Settings
Open accessAbstract
: The accurate assessment of sleep is critical to better understand and evaluate its role in health and disease. The boom in wearable technology is part of the digital health revolution and is producing many novel, highly sophisticated and relatively inexpensive consumer devices collecting data from multiple sensors and claiming to extract information about users' behaviors, including sleep. These devices are now able to capture different biosignals for determining, for example, HR and its variability, skin conductance, and temperature, in addition to activity. They perform 24/7, generating overwhelmingly large data sets (big data), with the potential of offering an unprecedented window on users' health. Unfortunately, little guidance exists within and outside the scientific sleep community for their use, leading to confusion and controversy about their validity and application. The current state-of-the-art review aims to highlight use, validation and utility of consumer wearable sleep-trackers in clinical practice and research. Guidelines for a standardized assessment of device performance is deemed necessary, and several critical factors (proprietary algorithms, device malfunction, firmware updates) need to be considered before using these devices in clinical and sleep research protocols. Ultimately, wearable sleep technology holds promise for advancing understanding of sleep health; however, a careful path forward needs to be navigated, understanding the benefits and pitfalls of this technology as applied in sleep research and clinical sleep medicine.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Sleep monitoring wearables now incorporate multi-sensor setups using accelerometers, heart rate monitors, and peripheral oxygen saturation sensors to capture comprehensive sleep-related data.
“These devices now incorporate multi-sensor setups, utilizing accelerometers, heart rate monitors, and peripheral oxygen saturation sensors to capture comprehensive sleep-related data [239].”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [239]
Sleep monitoring wearable devices have gained significant popularity in consumer health and sleep research in recent years as a non-invasive and convenient tool for tracking sleep patterns and assessing sleep quality.
“Sleep monitoring wearable devices have gained significant popularity in consumer health and sleep research in recent years as a non-invasive and convenient tool for tracking sleep patterns and assessing sleep quality [197,239] (Figure 7d).”
From The emergence of AI-based wearable sensors for digital health technology: a review (2023) · cites this paper as [239]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619 · see citing works
Cicchetti, D. V. (1994) · Psychological Assessment · doi:10.1037/1040-3590.6.4.284 · Cited by 9,349 · see citing works
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220 · see citing works
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,817 · see citing works
High agreement but low Kappa: I. the problems of two paradoxes
Feinstein, A. R., & Cicchetti, D. V. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90158-l · Cited by 3,034 · see citing works
Byrt, T., Bishop, J., & Carlin, J. B. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90018-v · Cited by 2,179 · see citing works
AASM Scoring Manual Updates for 2017 (Version 2.4)
Berry, R. B., Brooks, R., Gamaldo, C. E., Harding, S. M., Lloyd, R. M., Quan, S. F., Troester, M. M., & Vaughn, B. V. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6576 · Cited by 1,605 · see citing works
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415 · see citing works
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142 · see citing works
Marino, M., Li, Y., Rueschman, M. N., Winkelman, J. W., Ellenbogen, J. M., Solet, J. M., Dulin, H., Berkman, L. F., & Buxton, O. M. (2013) · Sleep · doi:10.5665/sleep.3142 · Cited by 1,056 · see citing works
Kushida, C. A., Chang, A., Patil, C. G., Guilleminault, C., Carrillo, O., & Dement, W. C. (2001) · Sleep Medicine · doi:10.1016/s1389-9457(00)00098-8 · Cited by 997 · see citing works
Swan, M. (2012) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan1030217 · Cited by 934 · see citing works
Hori, T., Sugita, Y., Koga, E., Shirakawa, S., Inoue, K., Uchida, S., Kuwahara, H., Kousaka, M., Kobayashi, T., Tsuji, Y., et al. (2001) · Psychiatry and Clinical Neurosciences · doi:10.1046/j.1440-1819.2001.00810.x · Cited by 811 · see citing works
Grandner, M. A. (2017) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2016.10.012 · Cited by 720 · see citing works
How accurate is pulse rate variability as an estimate of heart rate variability?
Schäfer, A., & Vagedes, J. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.03.119 · Cited by 661 · see citing works
Wearables and the Medical Revolution
Dunn, J., Runge, R., & Snyder, M. (2018) · Personalized Medicine · doi:10.2217/pme-2018-0044 · Cited by 654 · see citing works
Chambon, S., Galtier, M. N., Arnal, P. J., Wainrib, G., & Gramfort, A. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2813138 · Cited by 632 · see citing works
Further Validation of Actigraphy for Sleep Studies
de Souza, L., Benedito‐Silva, A. A., Pires, M. L. N., Poyares, D. R., Tufik, S., & Calil, H. M. (2003) · SLEEP · doi:10.1093/sleep/26.1.81 · Cited by 587 · see citing works
van de Water, A. T. M., HOLMES, A., & Hurley, D. A. (2010) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00814.x · Cited by 454 · see citing works
A validation study of Fitbit Charge 2™ compared with polysomnography in adults
de Zambotti, M., Goldstone, A., Claudatos, S. A., Colrain, I. M., & Baker, F. C. (2017) · Chronobiology International · doi:10.1080/07420528.2017.1413578 · Cited by 420 · see citing works
Self-citationNetwork Physiology: How Organ Systems Dynamically Interact
Bartsch, R. P., Liu, K. K. L., Bashan, A., & Ivanov, P. C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0142143 · Cited by 418 · see citing works
Agreement Rates Between Actigraphy, Diary, and Questionnaire for Children's Sleep Patterns
Werner, H., Molinari, L., Guyer, C., & Jenni, O. G. (2008) · Archives of Pediatrics and Adolescent Medicine · doi:10.1001/archpedi.162.4.350 · Cited by 384 · see citing works
Confidence in Altman–Bland plots: A critical review of the method of differences
Ludbrook, J. (2009) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2009.05288.x · Cited by 369 · see citing works
Wake Detection Capacity of Actigraphy During Sleep
Paquet, J., Kawinska, A., & Carrier, J. (2007) · SLEEP · doi:10.1093/sleep/30.10.1362 · Cited by 345 · see citing works
Direct Comparison of Two New Actigraphs and Polysomnography in Children and Adolescents
Meltzer, L. J., Walsh, C. M., Traylor, J. T., & Westin, A. M. L. (2011) · SLEEP · doi:10.5665/sleep.1608 · Cited by 339 · see citing works
Mantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314 · see citing works
Firouzi, F., Rahmani, A. M., Mankodiya, K., Badaroglu, M., Merrett, G. V., Wong, P., & Farahani, B. (2017) · Future Generation Computer Systems · doi:10.1016/j.future.2017.09.016 · Cited by 303 · see citing works
Sleep estimation from wrist movement quantified by different actigraphic modalities
Jean‐Louis, G., Kripke, D. F., Mason, W. J., Elliott, J. A., & Youngstedt, S. D. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00364-2 · Cited by 302 · see citing works
Movement toward a novel activity monitoring device
Montgomery-Downs, H. E., Insana, S. P., & Bond, J. A. (2012) · Sleep and Breathing · doi:10.1007/s11325-011-0585-y · Cited by 301 · see citing works
Quante, M., Kaplan, E. R., Cailler, M., Rueschman, M., Wang, R., Weng, J., Taveras, E. M., & Redline, S. (2018) · Nature and Science of Sleep · doi:10.2147/nss.s151085 · Cited by 298 · see citing works
The Sleep of the Ring: Comparison of the ŌURA Sleep Tracker Against Polysomnography
de Zambotti, M., Rosas, L., Colrain, I. M., & Baker, F. C. (2019) · Behavioral Sleep Medicine · doi:10.1080/15402002.2017.1300587 · Cited by 287 · see citing works
Self-citationSleep detection with an accelerometer actigraph: comparisons with polysomnography
Jean‐Louis, G., Kripke, D. F., Cole, R. J., Assmus, J. D., & Langer, R. D. (2001) · Physiology & Behavior · doi:10.1016/s0031-9384(00)00355-3 · Cited by 267 · see citing works
Consumer Sleep Technology: An American Academy of Sleep Medicine Position Statement
Khosla, S., Deak, M. C., Gault, D., Goldstein, C. A., Hwang, D., Kwon, Y., O’Hearn, D. J., Schutte-Rodin, S., Yurcheshen, M. E., Rosen, I. M., et al. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7128 · Cited by 243 · see citing works
A global quantification of “normal” sleep schedules using smartphone data
Walch, O., Cochran, A. L., & Forger, D. B. (2016) · Science Advances · doi:10.1126/sciadv.1501705 · Cited by 228 · see citing works
Meltzer, L. J., Hiruma, L., Avis, K. T., Montgomery‐Downs, H. E., & Valentin, J. (2015) · SLEEP · doi:10.5665/sleep.4918 · Cited by 228 · see citing works
How Accurately Does Wrist Actigraphy Identify the States of Sleep and Wakefulness?
Pollak, C. P., Tryon, W. W., Nagaraja, H. N., & Dzwonczyk, R. R. (2001) · SLEEP · doi:10.1093/sleep/24.8.957 · Cited by 223 · see citing works
de Zambotti, M., Baker, F. C., Willoughby, A. R., Godino, J. G., Wing, D., Patrick, K., & Colrain, I. M. (2016) · Physiology & Behavior · doi:10.1016/j.physbeh.2016.03.006 · Cited by 222 · see citing works
Self-citationValidation of an automated wireless system to monitor sleep in healthy adults
SHAMBROOM, J. R., FÁBREGAS, S. E., & JOHNSTONE, J. (2012) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00944.x · Cited by 216 · see citing works
Beattie, Z., Oyang, Y., Statan, A., Ghoreyshi, A., Pantelopoulos, A., Russell, A., & Heneghan, C. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9047 · Cited by 198 · see citing works
Dynamic coupling between the central and autonomic nervous systems during sleep: a review
de Zambotti, M., Trinder, J., Silvani, A., Colrain, I. M., & Baker, F. C. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.03.027 · Cited by 194 · see citing works
Self-citationOrthosomnia: are some patients taking the quantified self too far?
Baron, K. G., Abbott, S., Jao, N., Manalo, N., & Mullen, R. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6472 · Cited by 188 · see citing works
Baron, K. G., Duffecy, J., Berendsen, M. A., Cheung Mason, I., Lattie, E. G., & Manalo, N. C. (2018) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2017.12.002 · Cited by 186 · see citing works
Cellini, N., Buman, M. P., McDevitt, E. A., Ricker, A. A., & Mednick, S. C. (2013) · Chronobiology International · doi:10.3109/07420528.2013.782312 · Cited by 181 · see citing works
Self-citationSleep stage classification with ECG and respiratory effort
Fonseca, P. M., Long, X., Radha, M., Haakma, R., Aarts, R. M., & Rolink, J. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/10/2027 · Cited by 168 · see citing works
Clinical Use of a Home Sleep Apnea Test: An American Academy of Sleep Medicine Position Statement
Rosen, I. M., Kirsch, D. B., Chervin, R. D., Carden, K. A., Ramar, K., Aurora, R. N., Kristo, D. A., Malhotra, R. K., Martin, J. L., Olson, E. J., et al. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6774 · Cited by 167 · see citing works
Validation of Sleep-Tracking Technology Compared with Polysomnography in Adolescents
de Zambotti, M., Baker, F. C., & Colrain, I. M. (2015) · SLEEP · doi:10.5665/sleep.4990 · Cited by 160 · see citing works
Self-citationHearables: Multimodal physiological in-ear sensing
Goverdovsky, V., von Rosenberg, W., Nakamura, T., Looney, D., Sharp, D. J., Papavassiliou, C., Morrell, M. J., & Mandic, D. P. (2017) · Scientific Reports · doi:10.1038/s41598-017-06925-2 · Cited by 159 · see citing works
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155 · see citing works
Assessment of the Fitbit Charge 2 for monitoring heart rate
Benedetto, S., Caldato, C., Bazzan, E., Greenwood, D. C., Pensabene, V., & Actis, P. (2018) · PLOS ONE · doi:10.1371/journal.pone.0192691 · Cited by 149 · see citing works
Fonseca, P., Weysen, T., Goelema, M. S., Møst, E. I. S., Radha, M., Lunsingh Scheurleer, C., van den Heuvel, L., & Aarts, R. M. (2017) · SLEEP · doi:10.1093/sleep/zsx097 · Cited by 148 · see citing works
Kang, S.-G., Kang, J. M., Ko, K.-P., Park, S.-C., Mariani, S., & Weng, J. (2017) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2017.03.009 · Cited by 146 · see citing works
Toon, E., Davey, M. J., Hollis, S. L., Nixon, G. M., Horne, R. S. C., & Biggs, S. N. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5580 · Cited by 142 · see citing works
Validating Actigraphy as a Measure of Sleep for Preschool Children
Bélanger, M., Bernier, A., Paquet, J., Simard, V., & Carrier, J. (2013) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.2844 · Cited by 136 · see citing works
Staging Sleep in Polysomnograms: Analysis of Inter-Scorer Variability
Younes, M. K., Raneri, J. K., & Hanly, P. J. (2016) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.5894 · Cited by 134 · see citing works
Evaluation of a consumer fitness-tracking device to assess sleep in adults
de Zambotti, M., Claudatos, S., Inkelis, S., Colrain, I. M., & Baker, F. C. (2015) · Chronobiology International · doi:10.3109/07420528.2015.1054395 · Cited by 127 · see citing works
Self-citationAn Evaluation of Cardiorespiratory and Movement Features With Respect to Sleep-Stage Classification
Willemen, T., Deun, D. V., Verhaert, V., Vandekerckhove, M. M. P., Exadaktylos, V., Verbraecken, J. A., Huffel, S. V., Haex, B., & Sloten, J. V. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2276083 · Cited by 127 · see citing works
Rondanelli, M., Opizzi, A., Monteferrario, F., Antoniello, N., Manni, R., & Klersy, C. (2011) · Journal of the American Geriatrics Society · doi:10.1111/j.1532-5415.2010.03232.x · Cited by 126 · see citing works
Sleep devices: wearables and nearables, informational and interventional, consumer and clinical
Bianchi, M. T. (2017) · Metabolism · doi:10.1016/j.metabol.2017.10.008 · Cited by 124 · see citing works
Debellemanière, E., Chambon, S., Pinaud, C., Thorey, V., Dehaene, D., Léger, D., Chennaoui, M., Arnal, P. J., & Galtier, M. N. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00088 · Cited by 118 · see citing works
SleepAp: An Automated Obstructive Sleep Apnoea Screening Application for Smartphones
Behar, J. A., Roebuck, A., Shahid, M., Daly, J., Hallack, A., Palmius, N., Stradling, J. R., & Clifford, G. D. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2307913 · Cited by 112 · see citing works
Validation of Actigraphy in Middle Childhood
Meltzer, L. J., Wong, P. P. C., Biggs, S. N., Traylor, J. T., Kim, J. Y., Bhattacharjee, R., Narang, I., & Marcus, C. L. (2016) · SLEEP · doi:10.5665/sleep.5836 · Cited by 106 · see citing works
Cook, J. D., Prairie, M. L., & Plante, D. T. (2017) · Journal of Affective Disorders · doi:10.1016/j.jad.2017.04.030 · Cited by 105 · see citing works
Liang, Z., & Martell, M. A. C. (2018) · Journal of Healthcare Informatics Research · doi:10.1007/s41666-018-0013-1 · Cited by 105 · see citing works
Sleep Tracking, Wearable Technology, and Opportunities for Research and Clinical Care
Shelgikar, A. V., Anderson, P. F., & Stephens, M. R. (2016) · Chest · doi:10.1016/j.chest.2016.04.016 · Cited by 104 · see citing works
Lillehei, A. S., Halcón, L. L., Savik, K., & Reis, R. (2015) · The Journal of Alternative and Complementary Medicine · doi:10.1089/acm.2014.0327 · Cited by 102 · see citing works
Comparison of pulse rate variability with heart rate variability during obstructive sleep apnea
Khandoker, A. H., Karmakar, C. K., & Palaniswami, M. S. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.09.020 · Cited by 98 · see citing works
Shin, M., Swan, P., & Chow, C. M. (2015) · Sleep Science · doi:10.1016/j.slsci.2015.02.003 · Cited by 87 · see citing works
Ambulatory monitoring in the diagnosis and management of obstructive sleep apnoea syndrome
Corral‐Peñafiel, J., Pépin, J., & Barbé, F. (2013) · European Respiratory Review · doi:10.1183/09059180.00004213 · Cited by 87 · see citing works
Promises and Challenges in the Use of Consumer-Grade Devices for Sleep Monitoring
Roomkham, S., Lovell, D. R., Cheung, J., & Perrin, D. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2811735 · Cited by 84 · see citing works
The Effects of the Removal of Electronic Devices for 48 Hours on Sleep in Elite Judo Athletes
Dunican, I. C., Martin, D. T., Halson, S. L., Reale, R., DAWSON, B. T., Caldwell, J. A., Jones, M. J., & Eastwood, P. R. (2017) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0000000000001697 · Cited by 71 · see citing works
Pesonen, A., & Kuula, L. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7050 · Cited by 69 · see citing works
Younes, M. K., Kuna, S. T., Pack, A. I., Walsh, J. K., Kushida, C. A., Staley, B. A., & Pien, G. W. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6934 · Cited by 64 · see citing works
Sleep apps and the quantified self: blessing or curse?
den Bulck, J. V. (2015) · Journal of Sleep Research · doi:10.1111/jsr.12270 · Cited by 57 · see citing works
Cook, J. D., Eftekari, S. C., Dallmann, E., Sippy, M., & Plante, D. T. (2018) · Journal of Sleep Research · doi:10.1111/jsr.12789 · Cited by 57 · see citing works
Kang, S., Kang, J. M., Cho, S., Ko, K., Lee, Y. J., Lee, H., Kim, L., & Winkelman, J. W. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6564 · Cited by 51 · see citing works
Aktaruzzaman, M., Rivolta, M. W., Karmacharya, R., Scarabottolo, N., Pugnetti, L., Garegnani, M., Bovi, G., Scalera, G. M., Ferrarin, M., & Sassi, R. (2017) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2017.08.006 · Cited by 48 · see citing works
Cook, J. D., Prairie, M. L., & Plante, D. T. (2018) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.7120 · Cited by 47 · see citing works
Ward, T. M., Lentz, M. J., Kieckhefer, G. M., et al. (2011) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00923.x · Cited by 46 · see citing works
Gruwez, A., Libert, W., Ameye, L., & Bruyneel, M. (2017) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2017.03.008 · Cited by 45 · see citing works
How well does a commercially available wearable device measure sleep in young athletes?
Sargent, C., Lastella, M., Romyn, G., Versey, N. G., Miller, D. J., & Roach, G. D. (2018) · Chronobiology International · doi:10.1080/07420528.2018.1466800 · Cited by 45 · see citing works
Estimating sleep from multisensory armband measurements: validity and reliability in teens
Roane, B. M., Reen, E. V., Hart, C. N., Wing, R. R., & Carskadon, M. A. (2015) · Journal of Sleep Research · doi:10.1111/jsr.12317 · Cited by 43 · see citing works
Meltzer, L. J., Walsh, C. M., & Peightal, A. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1138-6 · Cited by 40 · see citing works
Fitbit Flex: an unreliable device for longitudinal sleep measures in a non-clinical population
Baroni, A., Bruzzese, J., Bartolo, C. A. D., & Shatkin, J. P. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1271-2 · Cited by 37 · see citing works
Herlan, A., Ottenbacher, J., Schneider, J., Riemann, D. W., & Feige, B. (2018) · Journal of Sleep Research · doi:10.1111/jsr.12694 · Cited by 37 · see citing works
Melton, B. F., Buman, M. P., Vogel, R. L., Harris, B. S., & Bigham, L. E. (2016) · Journal of Black Studies · doi:10.1177/0021934716653349 · Cited by 36 · see citing works
Validity of Actigraphy in Measurement of Sleep in Young Adults With Type 1 Diabetes
Farabi, S. S., Quinn, L. T., & Carley, D. W. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6580 · Cited by 36 · see citing works
0068 ESTIMATION OF SLEEP STAGES USING CARDIAC AND ACCELEROMETER DATA FROM A WRIST-WORN DEVICE
Beattie, Z., Pantelopoulos, A., Ghoreyshi, A., Oyang, Y., Statan, A., & Heneghan, C. (2017) · Sleep · doi:10.1093/sleepj/zsx050.067 · Cited by 29 · see citing works
Actigraphy in the digital health revolution: still asleep?
Goldstone, A., Baker, F. C., & de Zambotti, M. (2018) · SLEEP · doi:10.1093/sleep/zsy120 · Cited by 28 · see citing works
Self-citationKim, M. J., Lee, G.-H., Kim, C.-S., Kim, W. S., Chung, Y., Chung, S., & Lee, S. (2012) · Sleep And Breathing · doi:10.1007/s11325-012-0689-z · Cited by 27 · see citing works
Tonetti, L., Cellini, N., de Zambotti, M., Fabbri, M., Martoni, M., Fábregas, S. E., Stegagno, L., & Natale, V. (2013) · Physiology & Behavior · doi:10.1016/j.physbeh.2013.05.036 · Cited by 25 · see citing works
Self-citationLorenz, C., & Williams, A. J. (2017) · Current Opinion in Pulmonary Medicine · doi:10.1097/mcp.0000000000000425 · Cited by 24 · see citing works
Luik, A. I., Machado, P. F., & Espie, C. A. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0010-4 · Cited by 24 · see citing works
Maskevich, S., Jumabhoy, R., Dao, P., Stout, J. C., & Drummond, S. P. A. (2017) · Journal of Huntington s Disease · doi:10.3233/jhd-170251 · Cited by 23 · see citing works
Validation of an Automated Wireless System for Sleep Monitoring During Daytime Naps
Cellini, N., McDevitt, E. A., Ricker, A. A., Rowe, K. M., & Mednick, S. C. (2014) · Behavioral Sleep Medicine · doi:10.1080/15402002.2013.845782 · Cited by 22 · see citing works
Self-citationRidgers, N. D., Hnatiuk, J. A., Vincent, G. E., Timperio, A. F., Barnett, L. M., & Salmon, J. (2016) · Journal of science and medicine in sport · doi:10.1016/j.jsams.2016.02.009 · Cited by 22 · see citing works
The Impact of Wearable Device Enabled Health Initiative on Physical Activity and Sleep
Crowley, O. V., Pugliese, L., & Kachnowski, S. (2016) · Cureus · doi:10.7759/cureus.825 · Cited by 22 · see citing works
Parametric likelihoods for multiple non-fatal competing risks and death
Shen, Y., & Thall, P. F. (1998) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19980515)17:9 · Cited by 17 · see citing works
Tracking The Changing Landscape Of Corporate Wellness Companies
Abraham, J. M., & White, K. M. (2017) · Health Affairs · doi:10.1377/hlthaff.2016.1138 · Cited by 17 · see citing works
Hill, C. M., Bucks, R. S., Cellini, N., Motamedi‐Fakhr, S., Carroll, A., Heathcote, K., Webster, R. J., & Simpson, D. (2018) · SLEEP · doi:10.1093/sleep/zsy181 · Cited by 10 · see citing works
Self-citationSleepAp: An automated obstructive sleep apnoea screening application for smartphones
Behar, J. A., Roebuck, A., Shahid, M. F., Daly, J., Hallack, A., Palmius, N., Stradling, J. R., & Clifford, G. D. (2013) · Computing in cardiology · Cited by 5 · see citing works
How reliable are commercially available trackers in detecting daytime sleep
Lambrechtse, P., Ziesenitz, V. C., Cohen, A. F., van den Anker, J. N., & Bos, E. J. (2018) · British Journal of Clinical Pharmacology · doi:10.1111/bcp.13475 · Cited by 4 · see citing works
Flagged first, then by citations
Research works printed but not linked: 4
- [65]Kales A, Rechtschaffen A. A manual of standardized terminology, techniques and scoring system for sleep stages of human subjects. Bethesda, MD; 1968. 11422885
- [66]Baayen R Mixed-effects models In: Cohn AC, Fougeron C, Huffman MKeditors. The Oxford handbook of laboratory phonology: Oxford University Press; 2012, pp. 668– 77.
- [91]Daly J, Roebuck A, Palmius N SleepCare: obstructive sleep apnoea screening using mobile health technology. In: Proceedings of the Appropriate Healthcare Technologies for Low Resource Settings (AHT 2014) 2014 p. 1– 4.
- [101]Henning A, van de Ven K. ‘Counting your steps’: The use of wearable technology to promote employees’ health and wellbeing. In: Elsevier; 2017.
Cited by
Sorted by citations
The emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535 · see citing works
Metrics of sleep apnea severity: beyond the apnea-hypopnea index
Malhotra, A., Ayappa, I., Ayas, N., Collop, N., Kirsch, D., Mcardle, N., Mehra, R., Pack, A. I., Punjabi, N., White, D. P., et al. (2021) · SLEEP · doi:10.1093/sleep/zsab030 · Cited by 489 · see citing works
Miller, D. J., Sargent, C., & Roach, G. D. (2022) · Sensors · doi:10.3390/s22166317 · Cited by 328 · see citing works
“Despite actigraphy providing a practical alternative to PSG, some devices are limited to binary sleep/wake detection and require a manual download of the data after the device has been worn for a period of time [7].”
InfluentialWalch, O., Huang, Y., Forger, D., & Goldstein, C. (2019) · Sleep · doi:10.1093/sleep/zsz180 · Cited by 240 · see citing works
Stressing the accuracy: Wrist‐worn wearable sensor validation over different conditions
Menghini, L., Gianfranchi, E., Cellini, N., Patron, E., Tagliabue, M., & Sarlo, M. (2019) · Psychophysiology · doi:10.1111/psyp.13441 · Cited by 157 · see citing works
Self-citationGodino, J. G., Wing, D., de Zambotti, M., Baker, F. C., Bagot, K., Inkelis, S., Pautz, C., Higgins, M., Nichols, J., Brumback, T., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0237719 · Cited by 107 · see citing works
Papini, G. B., Fonseca, P., van Gilst, M. M., Bergmans, J. W. M., Vullings, R., & Overeem, S. (2020) · Scientific Reports · doi:10.1038/s41598-020-69935-7 · Cited by 90 · see citing works
Devine, J. K., Chinoy, E. D., Markwald, R. R., Schwartz, L. P., & Hursh, S. R. (2020) · Sensors · doi:10.3390/s21010076 · Cited by 32 · see citing works
Haresamudram, H., Tang, C. I., Suh, S., Lukowicz, P., & Plötz, T. (2025) · Proceedings of the ACM on Interactive Mobile Wearable and Ubiquitous Technologies · doi:10.1145/3729467 · Cited by 33 · see citing works
Comparison of Wearable and Clinical Devices for Acquisition of Peripheral Nervous System Signals
Bizzego, A., Gabrieli, G., Furlanello, C., & Esposito, G. (2020) · Sensors · doi:10.3390/s20236778 · Cited by 25 · see citing works
Ito-Masui, A., Sakamoto, R., Matsuo, E., Kawamoto, E., Motomura, E., Tanii, H., Yu, H., Sano, A., Imai, H., & Shimaoka, M. (2023) · Journal of Medical Internet Research · doi:10.2196/45834 · Cited by 20 · see citing works
Haresamudram, H., Tang, C. I., Suh, S., Lukowicz, P., & Ploetz, T. (2024) · arXiv · Cited by 31 · see citing works
“It seems appealing to end users to automatically track the steps they have taken during a day, count the repetitions of a free weights workout, analyze their sleep, or even estimate the calories they have burnt.”
- Authors
- DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C.
- Affiliations
- Center for Health Sciences, SRI International, Menlo Park, CA;
- University of Padua (IT)
- SRI International (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2019-02-19
- Volume
- 51
- Issue
- 7
- Pages
- 1538-1557
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- PMC
- PMC6579636
- OpenAlex
- W2918103210
- Cited by
- 564
- References
- 102
- Citations by year
- 2026: 125 · 2025: 106 · 2024: 88 · 2023: 89 · 2022: 58 · 2021: 54 · 2020: 29 · 2019: 15
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion, public-domain)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Padua Research Archive (University of Padova) (submittedVersion, public-domain)
- Funders
- Dipartimenti di Eccellenza
- Ministero dell’Istruzione, dell’Università e della Ricerca
- Università degli Studi di Padova
- National Institutes of Health
- Dipartimento di Psicologia Generale, Università degli Studi di Padova
- National Institute on Alcohol Abuse and Alcoholism (U01AA021696)
- National Heart, Lung, and Blood Institute (R01HL139652)
- National Institute of Biomedical Imaging and Bioengineering (U54EB020405)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- wearable sleep trackers, consumer wearable devices, sleep assessment, device validation, sleep research, heart rate variability, skin conductance, activity monitoring, proprietary algorithms, equipment failure, firmware updates, big data, digital health
- MeSH terms
- Sleep Latency, Wearable Electronic Devices, Age Factors, Equipment Failure, Humans, Monitoring, Physiologic, Sleep, Sleep Wake Disorders, Wakefulness, Reproducibility of Results, Polysomnography, Biomedical Research, Actigraphy
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review