Detection of non-ST-elevation myocardial infarction using magnetocardiogram: New information from spatiotemporal electrical activation map
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND AIM: Non-ST-segment elevation myocardial infarction (NSTEMI) cannot be easily detected in the emergency room. We evaluate a method to detect NSTEMI using 64-channel magnetocardiography (MCG). METHODS: MCG recordings were made in 20 NSTEMI patients (aged 59.7+/-12.4 years), 15 young (aged 26.8+/-3.4 years), and 13 age-matched control subjects (aged 57.3+/-3.6). We evaluated three approaches to analysis, including 1) determination when individual subjects' MCG results fell outside normal ranges for ten MCG parameters, 2) the magnetic field map at the T-wave peak (T-MFM), and 3) a pair of spatiotemporal activation graphs (STAGs) showing two projections of electrical excitation during repolarization. RESULTS: Significant differences were found between normal controls and patients for all MCG parameters. None of the healthy controls had more than four MCG abnormal parameters, whereas 19 NSTEMI patients (95%) were abnormal in more than four parameters. STAGs and T-MFM also showed clear differences between healthy controls and NSTEMI patients. CONCLUSIONS: These results suggest that the MCG is sensitive to changes in the cardiac electrical pathway after myocardial infarction as described by these graphs and parameters, and therefore MCG may be a useful tool to detect severe ischemic patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 2×
“Despite the limitations of ECG for its low sensitivities and specificities (3,4), ECG is expected to continue to be the primary screening tool until a new diagnostic tool appears providing enhanced information such as more accurate diagnosis results, localization ability for the ischemic area (or infarction area), and…”
BackgroundMagnetocardiography Predicts Coronary Artery Disease in Patients with Acute Chest Pain
Park, J., Hill, P. M., Chung, N., Hugenholtz, P. G., & Jung, F. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.00634.x · Cited by 109 · cited 3×
“quantify the altered activation pathway caused by the ischemic tissue damage to the electrical conduction pathway for its reorientation (18,23,24,47).”
BackgroundMethodSelf-citationLim, H. K., Kwon, H., Chung, N., Ko, Y.-G., Kim, J.-M., Kim, I.-S., & Park, Y.-K. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.10.013 · Cited by 52 · cited 5×
“It should be noted that the average values of parameters of AMC were smaller than those of YC which is not following the trend of the previous study (25,26) even though all values were within the normal range in Table II.”
MethodResultInfluentialSelf-citationMagnetocardiogram recordings in a nonshielded environment—reproducibility and ischemia detection
Steinberg, B. A., Roguin, A., Watkins, S. P., Hill, P., Fernando, D., & Resar, J. R. (2005) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2005.05611.x · Cited by 42
Dutz, S., Bellemann, M. E., Leder, U., & Haueisen, J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/1/011 · Cited by 39
Cited by
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
Huang, X., Chen, P., Tang, F., & Hua, N. (2021) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-200905 · Cited by 33
Bang, W.-D., Kim, K., Lee, Y.-H., Kwon, H., Park, Y., Pak, H.-N., Ko, Y.-G., Lee, M., & Joung, B. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1339 · Cited by 17
Self-citationHuang, X., Hua, N., Tang, F., & Zhang, S. (2020) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-20-121 · Cited by 10
Metadata
- Authors
- Kyoon Lim, H., Kim, K., Lee, Y.-H., & Chung, N.
- Venue
- Annals of Medicine
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 41
- Issue
- 7
- Pages
- 533-546
- ISSN
- 0785-3890 (ISSN-L)
- 1365-2060
- OpenAlex
- W1990093208
- Cited by
- 22
- References
- 5
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Detection of non-ST-elevation myocardial infarction using magnetocardiogram: New information from spatiotemporal electrical activation map. https://app.cochat.ai/papers/10.1080/07853890903107883
- The paper
- Kyoon Lim, H., Kim, K., Lee, Y.-H., & Chung, N. (2009). Detection of non-ST-elevation myocardial infarction using magnetocardiogram: New information from spatiotemporal electrical activation map. Annals of Medicine. https://doi.org/10.1080/07853890903107883
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.