CoChat

The influence of flow cell geometry related shear stresses on the distribution, structure and susceptibility of Pseudomonas aeruginosa 01 biofilms

Salek, M. Mehdi, Jones, Steven M., Martinuzzi, Robert J. · 2009 · Biofouling
Cited by 37

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The effects of non-uniform hydrodynamic conditions resulting from flow cell geometry (square and rectangular cross-section) on Pseudomonas aeruginosa 01 (PAO1) biofilm formation, location, and structure were investigated for nominally similar flow conditions using a combination of confocal scanning laser microscope (CSLM) and computational fluid dynamics (CFD). The thickness and surface coverage of PAO1 biofilms were observed to vary depending on the location in the flow cell and thus also the local wall shear stress. The biofilm structure in a 5:1 (width to height) aspect ratio rectangular flow cell was observed to consist mainly of a layer of bacterial cells with thicker biofilm formation observed in the flow cell corners. For square cross-section (1:1 aspect ratio) flow cells, generally thicker and more uniform surface coverage biofilms were observed. Mushroom shaped structures with hollow centers and wall breaks, indicative of 'seeding' dispersal structures, were found exclusively in the square cross-section tubes. Exposure of PAO1 biofilms grown in the flow cells to gentamicin revealed a difference in susceptibility. Biofilms grown in the rectangular flow cell overall exhibited a greater susceptibility to gentamicin compared to those grown in square flow cells. However, even within a given flow cell, differences in susceptibility were observed depending on location. This study demonstrates that the spanwise shear stress distribution within the flow cells has an important impact on the location of colonization and structure of the resultant biofilm. These differences in biofilm structure have a significant impact on the susceptibility of the biofilms grown within flow channels. The impact of flow modification due to flow cell geometry should be considered when designing flow cells for laboratory investigation of bacterial biofilms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/08927010903114603

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 37

Metadata

Authors
Salek, M. M., Jones, S. M., & Martinuzzi, R. J.
Venue
Biofouling
Published
2009-07-23
Volume
25
Issue
8
Pages
711-725
ISSN
  • 0892-7014 (ISSN-L)
  • 1029-2454
OpenAlex
W2060087637
Cited by
37
References
5
FWCI
1.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The influence of flow cell geometry related shear stresses on the distribution, structure and susceptibility of Pseudomonas aeruginosa 01 biofilms. https://app.cochat.ai/papers/10.1080/08927010903114603
The paper
Salek, M. M., Jones, S. M., & Martinuzzi, R. J. (2009). The influence of flow cell geometry related shear stresses on the distribution, structure and susceptibility of Pseudomonas aeruginosa 01 biofilms. Biofouling. https://doi.org/10.1080/08927010903114603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.