The DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index.
Mathematical Analysis of Particle Deposition in Human Lungs: An Improved Single Path Transport Model
Abstract
A dynamic single-path mathematical model was developed that is capable of analyzing detailed deposition patterns of inhaled particles in human lungs. Weibel's symmetric lung morphology was adopted as the basic lung structure, and detailed transport processes were evaluated numerically using the fully implicit procedure. Deposition efficiencies by specific mechanisms were individually examined for accuracy and new empirical formulas were incorporated whenever appropriate. Deposition in the alveolar region was divided into deposition fractions in the alveolar duct and alveoli, considering active transport processes between the two regions. The deposition fractions were obtained for each airway generation, serial lung volumetric compartments, and conventional three-compartment anatomic lung regions. In addition, the surface dose and cumulative deposition with time were analyzed. The results showed excellent agreement with available experimental data. The present model provides an improvement from the previously reported models and can be used as a tool in assessing internal dose of inhaled particles under various inhalation conditions.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Following human inhalation, the greatest deposition of particles/fibers is in the 16th to 19th generations of airways, which includes the respiratory bronchioles [85,86,87,88].”
From Asbestos and Iron (2023) · cites this paper as [87]
Citations
Cites
Numerical Heat Transfer and Fluid Flow
Patankar, S. V. (2018) · CRC Press eBooks · doi:10.1201/9781482234213 · Cited by 23,360
Numerical Heat Transfer and Fluid Flow
Hsu, C.-J. (1981) · Nuclear Science and Engineering · doi:10.13182/nse81-a20112 · Cited by 15,125
Weibel, E. R. (1963) · Springer eBooks · doi:10.1007/978-3-642-87553-3 · Cited by 3,353
Fuchs, N. A., Daisley, R. E., Fuchs, M., & Davies, C. N. (1964) · Cited by 2,278
Deposition of particles in the human respiratory tract in the size range 0.005–15 μm
Heyder, J., Gebhart, J., Rudolf, G., Schiller, C. F., & Stahlhofen, W. (1986) · Journal of Aerosol Science · doi:10.1016/0021-8502(86)90035-2 · Cited by 1,026
Models of human lung airways and their application to inhaled particle deposition
Yeh, H.-C., & Schum, G. M. (1980) · Bulletin of Mathematical Biology · doi:10.1007/bf02460796 · Cited by 717
Stahlhofen, W., Gebhart, J., & Heyder, J. (1980) · American Industrial Hygiene Association Journal · doi:10.1080/15298668091424933 · Cited by 444
Intercomparison of experimental regional aerosol deposition data
STAHLHOFEN, W., RUDOLF, G., & JAMES, A. C. (1989) · Journal of Aerosol Medicine · doi:10.1089/jam.1989.2.285 · Cited by 423
Particle Deposition in a Multiple-Path Model of the Human Lung
Asgharian, B., Hofmann, W., & Bergmann, R. (2001) · Aerosol Science and Technology · doi:10.1080/02786820119122 · Cited by 408
CHAN, T. L., & LIPPMANN, M. (1980) · American Industrial Hygiene Association Journal · doi:10.1080/15298668091424942 · Cited by 402
Research works printed but not linked: 2
- Egan M. J., 1985, Radiat. Protect. Dosim., 11, 15
- Kim C. S, 2000, Respir. Care, 45, 695
Cited by
Subchronic Inhalation Toxicity of Silver Nanoparticles
Sung, J. H., Ji, J. H., Park, J. D., Yoon, J. U., Kim, D. S., Jeon, K. S., Song, M. Y., Jeong, J., Han, B. S., Han, J. H., et al. (2009) · Toxicological Sciences · doi:10.1093/toxsci/kfn246 · Cited by 505
Modelling inhaled particle deposition in the human lung—A review
Hofmann, W. (2011) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2011.05.007 · Cited by 492
Sze To, G. N., & Chao, C. Y. H. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00621.x · Cited by 383
Airflow and Particle Transport in the Human Respiratory System
Kleinstreuer, C., & Zhang, Z. (2010) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-121108-145453 · Cited by 380
Deng, Q., Deng, L., Miao, Y., Guo, X., & Li, Y. (2019) · Environmental Research · doi:10.1016/j.envres.2018.11.014 · Cited by 302
Metadata
- Authors
- Choi, J.-I., & Kim, C. S.
- Affiliations
- University of North Carolina at Chapel Hill (US)
- Environmental Protection Agency (US)
- ORCID
- Choi, Jung-Il
- Venue
- Inhalation Toxicology
- Publisher
- Informa UK Limited
- Published
- 2007-01
- Volume
- 19
- Issue
- 11
- Pages
- 925-939
- ISSN
- 0895-8378 (ISSN-L)
- 1091-7691
- OpenAlex
- W2122711998
- Cited by
- 101
- References
- 40
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 5 · 2023: 5 · 2022: 7 · 2021: 6 · 2020: 9 · 2019: 6 · 2018: 9 · 2017: 2 · 2016: 6 · 2015: 3 · 2014: 4 · 2013: 2 · 2012: 1
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Inhalation Toxicology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Inhalation and Respiratory Drug Delivery
- Physical Sciences › Chemical Engineering › Fluid Flow and Transfer Processes › Particle Dynamics in Fluid Flows
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Keywords
- particle deposition, human lung, deposition efficiency, alveolar deposition, alveolar ducts, airway generation, internal dose, inhaled particles, surface dose
- MeSH terms
- Inhalation, Biological Transport, Computer Simulation, Humans, Lung, Models, Biological, Particle Size, Pulmonary Alveoli, Particulate Matter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mathematical Analysis of Particle Deposition in Human Lungs: An Improved Single Path Transport Model. https://app.cochat.ai/papers/10.1080/08958370701513014
- The paper
- Choi, J.-I., & Kim, C. S. (2007). Mathematical Analysis of Particle Deposition in Human Lungs: An Improved Single Path Transport Model. Inhalation Toxicology. https://doi.org/10.1080/08958370701513014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.