GMP Production of Liposomes—A New Industrial Approach
The DOI matches its Crossref record.
Abstract
A new scalable liposome production system is presented, which is based on the ethanol injection technique. The system permits liposome manufacture regardless of production scale, as scale is determined only by free disposable vessel volumes. Once the parameters are defined, an easy scale up can be performed by just changing the process vessels. These vessels are fully sterilizeable and all raw materials are transferred into the sanitized and sterilized system via 0.2 microm filters to guarantee an aseptic production. Liposome size can be controlled by the local lipid concentration at the injection point depending on process parameters like injection pressure, lipid concentration and injection rate. These defined process parameters are furthermore responsible for highly reproducible results with respect to vesicle diameters and encapsulation rates Compared to other technologies like the film method which is normally followed by size reduction through high pressure homogenization, ultrasonication or extrusion, no mechanical forces are needed to generate homogeneous and narrow distributed liposomes. Another important advantage of this method is the suitability for the entrapment of many different drug substances such as large hydrophilic proteins by passive encapsulation, small amphiphilic drugs by a one step remote loading technique or membrane association of antigens for vaccination approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New developments in liposomal drug delivery
Pattni, B. S., Chupin, V. V., & Torchilin, V. P. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00046 · Cited by 1,600
Adapting liposomes for oral drug delivery
He, H., Lu, Y., Qi, J., Zhu, Q., Chen, Z., & Wu, W. (2019) · Acta Pharmaceutica Sinica B · doi:10.1016/j.apsb.2018.06.005 · Cited by 663
Kraft, J. C., Freeling, J. P., Wang, Z., & Ho, R. J. Y. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23773 · Cited by 606
Sedlmeier, A., & Gorris, H. H. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00186a · Cited by 482
Nakhaei, P., Margiana, R., Bokov, D. O., Abdelbasset, W. K., Jadidi Kouhbanani, M. A., Varma, R. S., Marofi, F., Jarahian, M., & Beheshtkhoo, N. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.705886 · Cited by 479
Retracted
Metadata
- Authors
- Wagner, A., Platzgummer, M., Kreismayr, G., Quendler, H., Stiegler, G., Ferko, B., Vecera, G., Vorauer-Uhl, K., & Katinger, H.
- Venue
- Journal of Liposome Research
- Publisher
- Informa UK Limited
- Published
- 2006-01
- Volume
- 16
- Issue
- 3
- Pages
- 311-319
- ISSN
- 0898-2104 (ISSN-L)
- 1532-2394
- OpenAlex
- W965934091
- Cited by
- 106
- References
- 0
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: GMP Production of Liposomes—A New Industrial Approach. https://app.cochat.ai/papers/10.1080/08982100600851086
- The paper
- Wagner, A., Platzgummer, M., Kreismayr, G., Quendler, H., Stiegler, G., Ferko, B., Vecera, G., Vorauer-Uhl, K., & Katinger, H. (2006). GMP Production of Liposomes—A New Industrial Approach. Journal of Liposome Research. https://doi.org/10.1080/08982100600851086
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.