Cited by 39Retinal Imaging and AnalysisOphthalmology and Visual Health ResearchRetinal Diseases and Treatments

Telemedical Diabetic Retinopathy Screening in a Primary Care Setting: Quality of Retinal Photographs and Accuracy of Automated Image Analysis

Wintergerst, Maximilian W.M., Bejan, Veronica, Hartmann, Vera, Schnorrenberg, Marina, Bleckwenn, Markus, Weckbecker, Klaus, Finger, Robert P.·2022·Ophthalmic Epidemiology

Abstract

Background Screening for diabetic eye disease (DED) and general diabetes care is often separate, which leads to delays and low adherence to DED screening recommendations. Thus, we assessed the feasibility, achieved image quality, and possible barriers of telemedical DED screening in a point-of-care general practice setting and the accuracy of an automated algorithm for detection of DED. Methods Patients with diabetes were recruited at general practices. Retinal images were acquired using a non-mydriatic camera (CenterVue, Italy) by medical assistants. Images were quality assessed and double graded by two graders. All images were also graded automatically using a commercially available artificial intelligence (AI) algorithm (EyeArt version 2.1.0, Eyenuk Inc.). Results A total of 75 patients (147 eyes; mean age 69 years, 96% type 2 diabetes) were included. Most of the patients (51; 68%) preferred DED screening at the general practice, but only twenty-four (32%) were willing to pay for this service. Images of 63 patients (84%) were determined to be evaluable, and DED was diagnosed in 6 patients (8.0%). The algorithm's positive/negative predictive values (95% confidence interval) were 0.80 (0.28-0.99)/1.00 (0.92-1.00) and 0.75 (0.19-0.99)/0.98 (0.88-1.00) for detection of any DED and referral-warranted DED, respectively.Overall, the number of referrals was 18 (24%) for manual telemedical assessment and 31 (41%) for the artificial intelligence (AI) algorithm, resulting in a relati…

Integrity signals

Registry

Crossref · 10.1080/09286586.2021.1939886

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wintergerst, M. W. M., Bejan, V., Hartmann, V., Schnorrenberg, M., Bleckwenn, M., Weckbecker, K., & Finger, R. P.
Affiliations
  • University Hospital Bonn (DE)
  • Witten/Herdecke University (DE)
  • Leipzig University (DE)
Corresponding author
Finger, Robert P.
Venue
Ophthalmic Epidemiology
Published
2021-06-20
Volume
29
Issue
3
Pages
286-295
ISSN
  • 0928-6586 (ISSN-L)
  • 1744-5086
OpenAlex
W3174760049
Cited by
39
References
5
Citations by year
2026: 7 · 2025: 18 · 2024: 4 · 2023: 6 · 2022: 4
FWCI
1.81
Type
journal article
Language
en
Open access
closed
Locations
  • Ophthalmic Epidemiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Retinal Imaging and Analysis
  • Health Sciences › Medicine › Ophthalmology › Ophthalmology and Visual Health Research
  • Health Sciences › Medicine › Ophthalmology › Retinal Diseases and Treatments
Keywords
diabetic retinopathy screening, diabetic retinopathy, telemedicine, primary care, retinal image quality, automated image analysis, artificial intelligence, type 2 diabetes, patient acceptance, medical assistants, workflow integration
MeSH terms
Aged, Artificial Intelligence, Diabetes Mellitus, Type 2, Diabetic Retinopathy, Humans, Mass Screening, Photography, Primary Health Care, Sensitivity and Specificity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review