Comparison of a wireless dry headband technology for sleep monitoring with actigraphy in healthy adults
Abstract
The present study aimed to explore the validity of a wireless dry headband technology for long-term home sleep monitoring, through a comparison with concurrent actigraphic recording. Nineteen healthy volunteers (nine females; age range: 22–63 years) slept in their home simultaneously using the wireless dry sensor system (WS) and Basic Mini-Motionlogger® (MML) actigraph. In all we collected 204 valid actigraphic and wireless recordings. We focused on comparisons of these sleep measures: sleep onset latency, wake after sleep onset, total sleep time and sleep efficiency. WS overestimated sleep onset latency and wake after sleep onset in comparison to MML, and underestimated total sleep time and sleep efficiency. On the basis of the present data, WS can be considered a reliable tool for the long-term home sleep monitoring.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Zeo Sleep Manager has been validated as an accurate device for measuring sleep patterns in adults when compared against polysomnography and actigraphy.
“The Zeo Sleep Manager has been validated as an accurate device for measuring sleep patterns in adults when compared against polysomnography and actigraphy [60, 61].”
From A structural equation model of the relationship between insomnia, negative affect, and paranoid thinking (2017) · cites this paper as [61]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Automatic sleep/wake identification from wrist activity.
Cole, R., Kripke, D., Gruen, W., Mullaney, D., & Gillin, J. (1992) · Sleep · doi:10.1093/sleep/15.5.461 · Cited by 1,971 · see citing works
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142 · see citing works
Psychiatric Illness in General Practice: A Detailed Study Using a New Method of Case Identification
Goldberg, D. P., & Blackwell, B. (1970) · BMJ · doi:10.1136/bmj.2.5707.439 · Cited by 1,121 · see citing works
Further Validation of Actigraphy for Sleep Studies
de Souza, L., Benedito‐Silva, A. A., Pires, M. L. N., Poyares, D. R., Tufik, S., & Calil, H. M. (2003) · SLEEP · doi:10.1093/sleep/26.1.81 · Cited by 587 · see citing works
van de Water, A. T. M., HOLMES, A., & Hurley, D. A. (2010) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2009.00814.x · Cited by 454 · see citing works
Validation of an automated wireless system to monitor sleep in healthy adults
SHAMBROOM, J. R., FÁBREGAS, S. E., & JOHNSTONE, J. (2012) · Journal of Sleep Research · doi:10.1111/j.1365-2869.2011.00944.x · Cited by 216 · see citing works
Comparison of Two Different Actigraphs with Polysomnography in Healthy Young Subjects
Tonetti, L., Pasquini, F., Fabbri, M., Belluzzi, M., & Natale, V. (2008) · Chronobiology International · doi:10.1080/07420520801897228 · Cited by 103 · see citing works
Self-citationValidity of a Short Insomnia Questionnaire: the SDQ
Violani, C., Devoto, A., Lucidi, F., Lombardo, C., & Russo, P. M. (2004) · Brain Research Bulletin · doi:10.1016/j.brainresbull.2003.06.002 · Cited by 88 · see citing works
Dick, R., Penzel, T., Fietze, I., Partinen, M., Hein, H., & Schulz, J. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/12/005 · Cited by 53 · see citing works
Flagged first, then by citations
2 of the 12 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Scott, A. J., Rowse, G., & Webb, T. L. (2017) · PLOS ONE · doi:10.1371/journal.pone.0186233 · Cited by 30 · see citing works
“The Zeo Sleep Manager has been validated as an accurate device for measuring sleep patterns in adults when compared against polysomnography and actigraphy [60, 61].”
MethodA comparison of sleep patterns in youth soccer players and non-athletes
Whitworth‐Turner, C. M., Michele, R. D., Muir, I. H., Gregson, W. A., & Drust, B. (2017) · Science and Medicine in Football · doi:10.1080/24733938.2017.1366040 · Cited by 27 · see citing works
“Tonetti and Colleagues (2013) also demonstrated high sensitivity 97.6% in comparison to PSG, though lowered specificity (56.1”
BackgroundResultInfluentialTonetti, L., Cellini, N., de Zambotti, M., Fabbri, M., Martoni, M., Fábregas, S. E., Stegagno, L., & Natale, V. (2013) · Physiology & Behavior · doi:10.1016/j.physbeh.2013.05.036 · Cited by 25 · see citing works
“The WS performance has been compared with that of actigraphy to assess reliability in long-term home sleep monitoring [4].”
MethodResultSelf-citationValidation of an Automated Wireless System for Sleep Monitoring During Daytime Naps
Cellini, N., McDevitt, E. A., Ricker, A. A., Rowe, K. M., & Mednick, S. C. (2014) · Behavioral Sleep Medicine · doi:10.1080/15402002.2013.845782 · Cited by 22 · see citing works
“, 2013), the WS may be an excellent alternative to actigraphy for objective sleep monitoring outside the lab (Tonetti et al., 2012).”
BackgroundAN INVESTIGATION INTO THE SLEEPING PATTERNS OF YOUTH SOCCER PLAYERS DURING THE COMPETITIVE SEASON
Turner, C. (2016) · Liverpool John Moores University · doi:10.24377/ljmu.t.00004888
An Analysis of Sleep and Ergometer Performance in Collegiate Male Rowers
Babiec, T. (2021) · CommonHealth · doi:10.15367/ch.v2i1.398
Simulatore d’alba come possibile contromisura al social jetlag in adolescenza
Tonetti, L. (2013) · AMS Dottorato Institutional Doctoral Theses Repository (University of Bologna) · doi:10.6092/unibo/amsdottorato/5334
Self-citation
- Authors
- Tonetti, L., Fábregas, S. E., Fabbri, M., Occhionero, M., Erbacci, A., Martoni, M., & Natale, V.
- Affiliations
- University of Bologna (IT)
- Corresponding author
- Tonetti, Lorenzo
- Venue
- Biological Rhythm Research
- Publisher
- Informa UK Limited
- Published
- 2013-04
- Volume
- 44
- Issue
- 2
- Pages
- 333-338
- ISSN
- 0929-1016 (ISSN-L)
- 1744-4179
- OpenAlex
- W2025373217
- Cited by
- 7
- References
- 12
- Citations by year
- 2021: 1 · 2017: 2 · 2016: 1 · 2014: 1 · 2013: 2
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Biological Rhythm Research (publishedVersion)
- Archivio istituzionale della ricerca (Alma Mater Studiorum Università di Bologna) (submittedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi della Campania "Luigi Vanvitelli" (submittedVersion)
- Topics
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and Work-Related Fatigue
- Keywords
- actigraphy, home sleep monitoring, sleep latency, wake after sleep onset, total sleep time, sleep efficiency, sensor validity
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review