The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Single photon avalanche diodes (SPADs) for 1.5 μm photon counting applications
Abstract
The paper reports on the design and characterization of InGaAs/InP single photon avalanche diodes (SPADs) for photon counting applications at wavelengths near 1.5 µm. It is shown how lower internal electric field amplitudes can lead to reduced dark count rates, but at the expense of degraded afterpulsing behaviour and larger timing jitter. Dark count rate behaviour provides evidence of thermally assisted tunnelling with an average thermal activation energy of ∼0.14 eV between 150 K and 220 K. Afterpulsing behaviour exhibits a structure-dependent afterpulsing activation energy, which quantifies how carrier de-trapping varies with temperature. SPAD performance simultaneously exhibits a dark count rate of 10 kHz at a detection efficiency of 20% with timing jitter of 100 ps at 200 K, and with appropriate performance tradeoffs, we demonstrate a 200 K dark count rate as low as 3 kHz, a detection efficiency as high as 45%, and a timing jitter as low as 30 ps.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Performance and design of InGaAs/InP photodiodes for single-photon counting at 155 µm
Hiskett, P. A., Buller, G. S., Loudon, A. Y., Smith, J. M., Gontijo, I., Walker, A. C., Townsend, P. D., & Robertson, M. J. (2000) · Applied Optics · doi:10.1364/ao.39.006818 · Cited by 126
Cited by
Invited Review Article: Single-photon sources and detectors
Eisaman, M. D., Fan, J., Migdall, A., & Polyakov, S. V. (2011) · Review of Scientific Instruments · doi:10.1063/1.3610677 · Cited by 1,358
Advances in InGaAs/InP single-photon detector systems for quantum communication
Zhang, J., Itzler, M. A., Zbinden, H., & Pan, J.-W. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.59 · Cited by 436
Self-citationSingle-photon generation and detection
Buller, G. S., & Collins, R. J. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/1/012002 · Cited by 268
High performance planar germanium-on-silicon single-photon avalanche diode detectors
Vines, P., Kuzmenko, K., Kirdoda, J., Dumas, D. C. S., Mirza, M. M., Millar, R. W., Paul, D. J., & Buller, G. S. (2019) · Nature Communications · doi:10.1038/s41467-019-08830-w · Cited by 195
Waveguide-integrated superconducting nanowire single-photon detectors
Ferrari, S., Schuck, C., & Pernice, W. (2017) · Nanophotonics · doi:10.1515/nanoph-2018-0059 · Cited by 167
Metadata
- Authors
- Itzler, M. A., Ben-Michael, R., Hsu, C. F., Slomkowski, K., Tosi, A., Cova, S., Zappa, F., & Ispasoiu, R.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 2007-01-20
- Volume
- 54
- Issue
- 2-3
- Pages
- 283-304
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2089895902
- Cited by
- 162
- References
- 1
- FWCI
- 17.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single photon avalanche diodes (SPADs) for 1.5 μm photon counting applications. https://app.cochat.ai/papers/10.1080/09500340600792291
- The paper
- Itzler, M. A., Ben-Michael, R., Hsu, C. F., Slomkowski, K., Tosi, A., Cova, S., Zappa, F., & Ispasoiu, R. (2007). Single photon avalanche diodes (SPADs) for 1.5 μm photon counting applications. Journal of Modern Optics. https://doi.org/10.1080/09500340600792291
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.