A Direct Mapping Algorithm for Phase-measuring Profilometry
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A direct phase-to-height mapping algorithm for phase-measuring profilometry is presented and verified by experiments. The direct mapping formula can be generated by measuring the phases of several different parallel planes rather than geometric parameters of the optical system. Therefore, it can speed up the calculation and reduce systematic errors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Automated phase-measuring profilometry of 3-D diffuse objects
Srinivasan, V., Liu, H. C., & Halioua, M. (1984) · Applied Optics · doi:10.1364/ao.23.003105 · Cited by 1,002
Cited by
Status, challenges, and future perspectives of fringe projection profilometry
Xu, J., & Zhang, S. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106193 · Cited by 469
Calibration of fringe projection profilometry: A comparative review
Feng, S., Zuo, C., Zhang, L., Tao, T., Hu, Y., Yin, W., Qian, J., & Chen, Q. (2021) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2021.106622 · Cited by 347
Three-dimensional surface profile intensity correction for spatially modulated imaging
Gioux, S., Mazhar, A., Cuccia, D. J., Durkin, A. J., Tromberg, B. J., & Frangioni, J. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3156840 · Cited by 161
“30 This technique consists of vertically translating a horizontal flat surface and acquiring, for known heights, the phase at each pixel location.”
MethodWirth, D. J., Sibai, M., Wilson, B. C., Roberts, D. W., & Paulsen, K. (2020) · Biomedical Optics Express · doi:10.1364/boe.397507 · Cited by 14
Metadata
- Authors
- Zhou, W.-S., & Su, X.-Y.
- Venue
- Journal of Modern Optics
- Publisher
- Informa UK Limited
- Published
- 1994-01
- Volume
- 41
- Issue
- 1
- Pages
- 89-94
- ISSN
- 0950-0340 (ISSN-L)
- 1362-3044
- OpenAlex
- W2009812416
- Cited by
- 168
- References
- 1
- FWCI
- 1.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.