Flow cytometric measurement of microparticles: Pitfalls and protocol modifications
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Upon activation, many cells shed components of their plasma membranes as microparticles. Depending on the methods of preparation and analyses, microparticle counts may vary significantly between laboratories, making data analyses and clinical correlations challenging. To assess how variations in sample preparation affect microparticle measurements, blood samples from 13 healthy, adult volunteers were labeled with Annexin V, cell-specific antibodies, and antibodies against tissue factor (TF). Data were acquired and analysed using an EPICS XL-MCL flow cytometer. Annexin V(+) monocyte-, platelet-, endothelial-, or erythrocyte-derived microparticles accounted for 10.4%, 38.5%, 43.8%, and 7.3% of the total number of microparticles (13.7 +/- 3.0 x 10(3)/ml of whole blood), respectively. A similar distribution of cell types was seen for TF(+) microparticles (6.3 +/- 2.6 x 10(3)/ml of whole blood). No statistical difference was noted in microparticle distribution using either 19- or 21-gauge needles. Elevated levels of platelet- and erythrocyte-derived microparticles were detected in heparin and PPACK-anticoagulated samples as compared to samples anticoagulated with ACD or sodium citrate (P < 0.05, student's t-test). Additional centrifugation was critical for removing platelet contamination, which significantly affected microparticle counts. Finally, Annexin V(+) and TF(+) microparticles were significantly reduced upon sample storage at low temperatures. Microparticle levels are sign…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Under normal physiological conditions, erythrocyte-derived EVs constitute 7.3% of EVs in whole blood, indicating that RBCs are one of the main sources of EVs in peripheral blood”
From Red Blood Cells as Potential Repositories of MicroRNAs in the Circulatory System (2020) · cites this paper as Shah et al., 2008
In the citing paper
“indicating that RBCs are one of the main sources of EVs in peripheral blood”
From Red Blood Cells as Potential Repositories of MicroRNAs in the Circulatory System (2020) · cites this paper as Shah et al., 2008
Citations
Cites
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (2000) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s004240000307 · Cited by 898
Circulating microparticles: pathophysiology and clinical implications
Piccin, A., Murphy, W. G., & Smith, O. P. (2007) · Blood Reviews · doi:10.1016/j.blre.2006.09.001 · Cited by 799
Cell-derived Microparticles Circulate in Healthy Humans and Support Low Grade Thrombin Generation
Nieuwland, R., Böing, A., Romijn, F., Hack, C. E., Sturk, A., & Berckmans, R. (2001) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1615646 · Cited by 651
Shet, A. S., Aras, O., Gupta, K., Hass, M. J., Rausch, D. J., Saba, N., Koopmeiners, L., Key, N. S., & Hebbel, R. P. (2003) · Blood · doi:10.1182/blood-2003-03-0693 · Cited by 539
Measuring circulating cell‐derived microparticles
Jy, W., Horstman, L. L., Jimenez, J. J., & Ahn, Y. S. (2004) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2004.00936.x · Cited by 411
Biochemical and Molecular Aspects of the Coagulation Cascade
Davie, E. W. (1995) · Thrombosis and Haemostasis · doi:10.1055/s-0038-1642645 · Cited by 256
Role of P-selectin and PSGL-1 in coagulation and thrombosis
R.Vandendries, E., Furie, B., & Furie, B. (2004) · Thrombosis and Haemostasis · doi:10.1160/th04-05-0306 · Cited by 208
Centrifugation attenuates the fluid shear response of circulating leukocytes
Fukuda, S., & Schmid‐Schönbein, G. W. (2002) · Journal of Leukocyte Biology · doi:10.1189/jlb.72.1.133 · Cited by 80
Kunzelmann, C., Toti, F., Zhang, Y., Nawroth, P. P., Morrissey, J. H., Freyssinet, J., & Satta, N. (2000) · Thrombosis and Haemostasis · doi:10.1055/s-0037-1613800 · Cited by 40
Cited by
Witwer, K. W., Buzás, E. I., Bemis, L. T., Bora, A., Lässer, C., Lötvall, J., Nolte‐‘t Hoen, E. N., Piper, M. G., Sivaraman, S., Skog, J., et al. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.20360 · Cited by 2,421
Methodological Guidelines to Study Extracellular Vesicles
Coumans, F. A. W., Brisson, A. R., Buzas, E. I., Dignat-George, F., Drees, E. E. E., El-Andaloussi, S., Emanueli, C., Gasecka, A., Hendrix, A., Hill, A. F., et al. (2017) · Circulation Research · doi:10.1161/circresaha.117.309417 · Cited by 1,017
Optical and non‐optical methods for detection and characterization of microparticles and exosomes
VAN DER POL, E., HOEKSTRA, A. G., STURK, A., OTTO, C., VAN LEEUWEN, T. G., & NIEUWLAND, R. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04074.x · Cited by 535
Boriachek, K., Islam, M. N., Möller, A., Salomon, C., Nguyen, N., Hossain, M. S. A., Yamauchi, Y., & Shiddiky, M. J. A. (2018) · Small · doi:10.1002/smll.201702153 · Cited by 495
CHANDLER, W. L., YEUNG, W., & TAIT, J. F. (2011) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2011.04283.x · Cited by 273
Pre-analytical and analytical issues in the analysis of blood microparticles
Yuana, Y., Bertina, R., & Osanto, S. (2011) · Thrombosis and Haemostasis · doi:10.1160/th10-09-0595 · Cited by 268
Jørgensen, M., Bæk, R., Pedersen, S., Søndergaard, E. K. L., Kristensen, S. R., & Varming, K. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.20920 · Cited by 252
Circulating microparticles: square the circle
Barteneva, N. S., Fasler-Kan, E., Bernimoulin, M., Stern, J. N., Ponomarev, E. D., Duckett, L., & Vorobjev, I. A. (2013) · BMC Cell Biology · doi:10.1186/1471-2121-14-23 · Cited by 245
“Sodium citrate is the most widely used anticoagulant [23]; however, blood collected with sodium citrate usually gives significantly lower levels of PS-positive MPs than blood collected in heparin [24].”
BackgroundMethodInfluentialAnalytical challenges of extracellular vesicle detection: A comparison of different techniques
Erdbrügger, U., & Lannigan, J. (2016) · Cytometry Part A · doi:10.1002/cyto.a.22795 · Cited by 230
“Freezing has been shown to affect MP quantification (30,31).”
BackgroundMethodMethodology for isolation, identification and characterization of microvesicles in peripheral blood
Jayachandran, M., Miller, V. M., Heit, J. A., & Owen, W. G. (2012) · Journal of Immunological Methods · doi:10.1016/j.jim.2011.10.012 · Cited by 227
Burger, D., & Touyz, R. M. (2012) · Journal of the American Society of Hypertension · doi:10.1016/j.jash.2011.11.003 · Cited by 213
Puddu, P., Puddu, G. M., Cravero, E., Muscari, S., & Muscari, A. (2010) · Canadian Journal of Cardiology · doi:10.1016/s0828-282x(10)70371-8 · Cited by 179
“However, the wide variety of methodologies used by different laboratories to measure circulating MPs has occasionally provided inconsistent or conflicting results (32), making data analysis and clinical correlations challenging (33).”
BackgroundBrain-derived microparticles induce systemic coagulation in a murine model of traumatic brain injury
Tian, Y., Salsbery, B., Wang, M., Yuan, H., Yang, J., Zhao, Z., Wu, X., Zhang, Y., Konkle, B. A., Thiagarajan, P., et al. (2015) · Blood · doi:10.1182/blood-2014-09-598805 · Cited by 173
Self-citationSHANTSILA, E., KAMPHUISEN, P. W., & LIP, G. Y. H. (2010) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2010.04007.x · Cited by 160
Red Blood Cells as Potential Repositories of MicroRNAs in the Circulatory System
Sun, L., Yu, Y., Niu, B., & Wang, D. (2020) · Frontiers in Genetics · doi:10.3389/fgene.2020.00442 · Cited by 83
“Under normal physiological conditions, erythrocyte-derived EVs constitute 7.3% of EVs in whole blood, indicating that RBCs are one of the main sources of EVs in peripheral blood (Shah et al., 2008; Duan et al., 2016).”
BackgroundInfluentialMobarrez, F., Fuzzi, E., Gunnarsson, I., Larsson, A., Eketjäll, S., Pisetsky, D. S., & Svenungsson, E. (2019) · Journal of Autoimmunity · doi:10.1016/j.jaut.2019.05.003 · Cited by 68
Selection of urinary sediment miRNAs as specific biomarkers of IgA nephropathy
Duan, Z.-Y., Cai, G.-Y., Bu, R., Lu, Y., Hou, K., & Chen, X.-M. (2016) · Scientific Reports · doi:10.1038/srep23498 · Cited by 61
Extracellular vesicles and lipoproteins – Smart messengers of blood cells in the circulation
Nguyen, P. H. D., Le, A. H., Pek, J. S. Q., Pham, T. T., Jayasinghe, M. K., Do, D. V., Phung, C. D., & Le, M. T. N. (2022) · Journal of Extracellular Biology · doi:10.1002/jex2.49 · Cited by 31
Metadata
- Authors
- Shah, M. D., Bergeron, A. L., Dong, J.-F., & López, J. A.
- Venue
- Platelets
- Publisher
- Informa UK Limited
- Published
- 2008-01
- Volume
- 19
- Issue
- 5
- Pages
- 365-372
- ISSN
- 0953-7104
- 1369-1635
- Cited by
- 140
- References
- 9
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.