The response of gamma -H2AX in human lymphocytes and lymphocytes subsets measured in whole blood cultures
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
PURPOSE: To assess the use of phosphorylated histone H2AX protein (gamma-H2AX) in human blood leukocytes as a rapid screening tool for radiation biodosimetry using a method that examines the characteristics of gamma-H2AX phosphorylation in a variety of lymphocyte subsets following exposure to radiation. MATERIALS AND METHODS: Human peripheral blood exposed to 0-10 Gy of (137)Cs irradiation and cultured for 0-48 h was analysed using a rapid whole blood flow cytometry assay to measure gamma-H2AX phosphorylation in different lymphocyte subpopulations. RESULTS: Lymphocyte subsets displayed a similar linear dose response relationship, although cluster of differentiation 4(+) (CD4(+)) and CD8(+) lymphocytes were found to express H2AX phosphorylation on the order of 1.5 times higher than CD19(+) lymphocytes. Phosphorylation of all lymphocyte subsets reached a maximum at 1.5 h and had essentially returned to baseline levels 24 h post-exposure. CONCLUSIONS: Differences in the expression level of gamma-H2AX between lymphocyte subsets were minimal. The usefulness of this assay for radiation biodosimetry is hampered by its relatively quick lifetime kinetics and large inter-individual variation. Therefore, it could only be useful if samples were obtained within 24 h of exposure. Even in this situation, the assay could only be used as an indicator of exposure and not a dosimeter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
DNA double-stranded breaks induce histone H2AX phosphorylation on serine 139
Rogakou, E. P., Pilch, D. R., Orr, A. H., Ivanova, V. S., & Bonner, W. M. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.10.5858 · Cited by 5,438 · cited 3×
“This phosphorylated H2AX (g-H2AX) appears within minutes of the induction of DSB, increasing with time up to 20–30 min and subsequently dephosphorylating over the next few hours (Rogakou et al. 1998, 1999, Pilch et al. 2003, Antonelli et al. 2005).”
BackgroundResultMegabase Chromatin Domains Involved in DNA Double-Strand Breaks in Vivo
Rogakou, E. P., Boon, C., Redon, C., & Bonner, W. M. (1999) · The Journal of Cell Biology · doi:10.1083/jcb.146.5.905 · Cited by 2,422 · cited 4×
“This phosphorylated H2AX (g-H2AX) appears within minutes of the induction of DSB, increasing with time up to 20–30 min and subsequently dephosphorylating over the next few hours (Rogakou et al. 1998, 1999, Pilch et al. 2003, Antonelli et al. 2005).”
BackgroundResultInfluentialInternational Journal of Radiation Biology
(1959) · Nature · doi:10.1038/1831020c0 · Cited by 1,986
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
Rothkamm, K., & Löbrich, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0830918100 · Cited by 1,645 · cited 3×
“…previous studies support the idea that the exact form of time response varies with received doses and the type of cells, although irradiation conditions could also have an effect on the response time (Rothkamm and Löbrich 2003, MacPhail et al. 2003a, Banath et al. 2004, Löbrich et al. 2005).”
BackgroundResultGenomic Instability in Mice Lacking Histone H2AX
Celeste, A., Petersen, S., Romanienko, P. J., Fernandez-Capetillo, O., Chen, H. T., Sedelnikova, O. A., Reina-San-Martin, B., Coppola, V., Meffre, E., Difilippantonio, M. J., et al. (2002) · Science · doi:10.1126/science.1069398 · Cited by 1,385 · cited 10×
“This phosphorylated H2AX (g-H2AX) appears within minutes of the induction of DSB, increasing with time up to 20–30 min and subsequently dephosphorylating over the next few hours (Rogakou et al. 1998, 1999, Pilch et al. 2003, Antonelli et al. 2005).”
BackgroundInfluentialH2AX: the histone guardian of the genome
Fernandez-Capetillo, O., Lee, A., Nussenzweig, M., & Nussenzweig, A. (2004) · DNA Repair · doi:10.1016/j.dnarep.2004.03.024 · Cited by 1,010 · cited 9×
“Due to the ease of visualisation of these foci, measuring g-H2AX has become a standard method for detecting the induction and repair of DNA DSB (Fernandez-Capetillo et al. 2004) and is now being used in large sample size studies such as using DNA damage to determine the applied integral body dose after radiotherapy (S…”
BackgroundMethodInfluentialHistone H2AX phosphorylation is dispensable for the initial recognition of DNA breaks
Celeste, A., Fernandez-Capetillo, O., Kruhlak, M. J., Pilch, D. R., Staudt, D. W., Lee, A., Bonner, R. F., Bonner, W. M., & Nussenzweig, A. (2003) · Nature Cell Biology · doi:10.1038/ncb1004 · Cited by 989 · cited 10×
“This phosphorylated H2AX (g-H2AX) appears within minutes of the induction of DSB, increasing with time up to 20–30 min and subsequently dephosphorylating over the next few hours (Rogakou et al. 1998, 1999, Pilch et al. 2003, Antonelli et al. 2005).”
BackgroundInfluentialCharacteristics of γ-H2AX foci at DNA double-strand breaks sites
Pilch, D. R., Sedelnikova, O. A., Redon, C., Celeste, A., Nussenzweig, A., & Bonner, W. M. (2003) · Biochemistry and Cell Biology · doi:10.1139/o03-042 · Cited by 451 · cited 3×
“This phosphorylated H2AX (g-H2AX) appears within minutes of the induction of DSB, increasing with time up to 20–30 min and subsequently dephosphorylating over the next few hours (Rogakou et al. 1998, 1999, Pilch et al. 2003, Antonelli et al. 2005).”
BackgroundIn vivo formation and repair of DNA double-strand breaks after computed tomography examinations
Löbrich, M., Rief, N., Kühne, M., Heckmann, M., Fleckenstein, J., Rübe, C., & Uder, M. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0501895102 · Cited by 426 · cited 8×
“This supports previous findings that radioresistant cultures dephosphorylate faster then radiosensitive ones (MacPhail et al. 2003a, Banath et al. 2004, Taneja et al. 2004, Löbrich et al. 2005).”
BackgroundMethodResultInfluentialBanáth, J. P., MacPhail, S. H., & Olive, P. L. (2004) · Cancer Research · doi:10.1158/0008-5472.can-04-1433 · Cited by 340 · cited 5×
“This supports previous findings that radioresistant cultures dephosphorylate faster then radiosensitive ones (MacPhail et al. 2003a, Banath et al. 2004, Taneja et al. 2004, Löbrich et al. 2005).”
BackgroundResultInfluential
Cited by
Use of the γ-H2AX assay to monitor DNA damage and repair in translational cancer research
Ivashkevich, A., Redon, C. E., Nakamura, A. J., Martin, R. F., & Martin, O. A. (2012) · Cancer Letters · doi:10.1016/j.canlet.2011.12.025 · Cited by 462
Hashimoto, T., Horikawa, D. D., Saito, Y., Kuwahara, H., Kozuka-Hata, H., Shin-I, T., Minakuchi, Y., Ohishi, K., Motoyama, A., Aizu, T., et al. (2016) · Nature Communications · doi:10.1038/ncomms12808 · Cited by 394
Review of retrospective dosimetry techniques for external ionising radiation exposures
Ainsbury, E. A., Bakhanova, E., Barquinero, J. F., Brai, M., Chumak, V., Correcher, V., Darroudi, F., Fattibene, P., Gruel, G., Guclu, I., et al. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncq499 · Cited by 301
Persistent γH2AX: A promising molecular marker of DNA damage and aging
Siddiqui, M. S., François, M., Fenech, M. F., & Leifert, W. R. (2015) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2015.07.001 · Cited by 262
“mrr intra-individual variation in the level of gH2AX foci in different subsets of lymphocytes [80]; (v) there is minimal intra-individual variation in gH2AX foci number per lymphocytes, and therefore, the assay is relatively efficient at measuring differences in gH2AX between individuals [34,78,80].”
BackgroundγH2AX as a marker of DNA double strand breaks and genomic instability in human population studies
Valdiglesias, V., Giunta, S., Fenech, M., Neri, M., & Bonassi, S. (2013) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2013.02.001 · Cited by 277
Sullivan, J. M., Prasanna, P. G. S., Grace, M. B., Wathen, L. K., Wallace, R. L., Koerner, J. F., & Coleman, C. N. (2013) · Health Physics · doi:10.1097/hp.0b013e31829cf221 · Cited by 192
“It is therefore advised that processing should be performed within 1Y2 d of the radiation exposure with the best time point at about 30 min to 1 h post-exposure (Andrievski and Wilkins 2009; HPA 2009; Rothkamm and Horn 2009; Garty et al. 2010).”
BackgroundGamma-H2AX-Based Dose Estimation for Whole and Partial Body Radiation Exposure
Horn, S., Barnard, S., & Rothkamm, K. (2011) · PLoS ONE · doi:10.1371/journal.pone.0025113 · Cited by 164
“As an alternative to scoring c-H2AX foci by immunofluorescence microscopy, c-H2AX can also be quantified by flow cytometry [14,15].”
MethodIonizing radiation biomarkers in epidemiological studies – An update
Hall, J. A., Jeggo, P. A., West, C., Gomolka, M., Quintens, R., Badie, C., Laurent, O., Aerts, A., Anastasov, N., Azimzadeh, O., et al. (2017) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2017.01.001 · Cited by 165
Laßmann, M., Hänscheid, H., Gassen, D., Biko, J., Meineke, V., Reiners, C., & Scherthan, H. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.071357 · Cited by 152
“Andrievski and Wilkins (14) concluded that the usefulness of g-H2AX for radiation biodosimetry was hampered by the marker’s relatively short life span and the large interindividual variation in the magnitude of marker induction.”
BackgroundMethodResultInfluentialIonizing radiation-induced cellular senescence promotes tissue fibrosis after radiotherapy. A review
Nguyen, H. Q., To, N. H., Zadigue, P., Kerbrat, S., De La Taille, A., Le Gouvello, S., & Belkacemi, Y. (2018) · Critical Reviews in Oncology/Hematology · doi:10.1016/j.critrevonc.2018.06.012 · Cited by 120
Use of γH2AX and Other Biomarkers of Double-Strand Breaks During Radiotherapy
Sak, A., & Stuschke, M. (2010) · Seminars in Radiation Oncology · doi:10.1016/j.semradonc.2010.05.004 · Cited by 143
Serum microRNAs are early indicators of survival after radiation-induced hematopoietic injury
Acharya, S. S., Fendler, W. M., Watson, J., Hamilton, A., Pan, Y., Gaudiano, E. F., Moskwa, P., Bhanja, P., Saha, S., Guha, C., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa6593 · Cited by 126
Impact of cardiac magnetic resonance imaging on human lymphocyte DNA integrity
Fiechter, M., Stehli, J., Fuchs, T. A., Dougoud, S., Gaemperli, O., & Kaufmann, P. A. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht184 · Cited by 95
Potential application of γ-H2AX as a biodosimetry tool for radiation triage
Raavi, V., Venkatachalam, P., & Paul, S. F. D. (2020) · Mutation Research/Reviews in Mutation Research · doi:10.1016/j.mrrev.2020.108350 · Cited by 94
High Throughput Measurement of γH2AX DSB Repair Kinetics in a Healthy Human Population
Sharma, P. M., Ponnaiya, B., Taveras, M., Shuryak, I., Turner, H. C., & Brenner, D. J. (2015) · PLoS ONE · doi:10.1371/journal.pone.0121083 · Cited by 95
“In agreement with this study, previous studies conducted using human lymphocytes found maximum γ-H2AX foci induction at 1–2 h post exposure [12, 41].”
DNA Protection Protein, a Novel Mechanism of Radiation Tolerance: Lessons from Tardigrades
Hashimoto, T., & Kunieda, T. (2017) · Life · doi:10.3390/life7020026 · Cited by 92
Beels, L., Werbrouck, J., & Thierens, H. M. (2010) · International Journal of Radiation Biology · doi:10.3109/09553002.2010.484479 · Cited by 91
“It has been demonstrated that the lymphocyte subsets show small differences in expression of H2AX phosphorylation measured by flow cytometry (Andrievski and Wilkins 2009).”
BackgroundAdapting the γ-H2AX Assay for Automated Processing in Human Lymphocytes. 1. Technological Aspects
Turner, H. C., Brenner, D. J., Chen, Y., Bertucci, A., Zhang, J., Wang, H., Lyulko, O. V., Xu, Y., Shuryak, I., Schaefer, J., et al. (2010) · Radiation Research · doi:10.1667/rr2125.1 · Cited by 84
“While it is considered that in this situation the c-H2AX yield would no longer be representative of the initial radiation dose received, and thus measurements of c-H2AX levels at this time would be indicators of exposure and not necessarily a reflection of absorbed dose (20), recent in vivo studies have observed a dos…”
Greve, B., Bölling, T., Amler, S., Rößler, U., Gomolka, M., Mayer, C., Popanda, O., Dreffke, K., Rickinger, A., Fritz, E., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047185 · Cited by 78
“In line with numerous other studies in which the radiation-induced histone H2AX phosphorylation was analysed in human PBLs [47,48,49], both laboratories showed a maximum of cH2AX-fluorescence after 1 h to 4 h and an almost complete repair 24 h later for both, PBLs and LCLs.”
BackgroundLaboratory Intercomparison on the γ-H2AX Foci Assay
Rothkamm, K., Horn, S., Scherthan, H., Rößler, U., Amicis, A. D., Barnard, S. G. R., Kulka, U., Lista, F. R., Meineke, V., Braselmann, H., et al. (2013) · Radiation Research · doi:10.1667/rr3238.1 · Cited by 65
Denoyer, D., Lobachevsky, P. N., Jackson, P. A., Thompson, M., Martin, O. A., & Hicks, R. J. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.145581 · Cited by 67
Runge, R., Hiemann, R., Wendisch, M., Kasten-Pisula, U., Storch, K., Zöphel, K., Fritz, C., Roggenbuck, D., Wunderlich, G., Conrad, K., et al. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2012.658468 · Cited by 71
“Yet there are some limitations to these methods, such as loss of sensitivity (Andrievski and Wilkins 2009).”
BackgroundGarty, G. Y., Chen, Y., Turner, H. C., Zhang, J., Lyulko, O. V., Bertucci, A., Xu, Y., Wang, H., Simaan, N., Randers-Pehrson, G., et al. (2011) · International Journal of Radiation Biology · doi:10.3109/09553002.2011.573612 · Cited by 58
“This is a simpler, faster and more reliable (at high doses) (Rogakou et al. 1998, Andrievski and Wilkins 2009) approach than the more common foci-counting, which requires highresolution 3D imaging (Böcker and Iliakis 2006, Hou et al. 2009, Roch-Lefèvre et al. 2010) and underestimates doses above…”
BackgroundOxidative changes and apoptosis induced by 1800-MHz electromagnetic radiation in NIH/3T3 cells
Hou, Q., Wang, M., Wu, S., Ma, X., An, G., Liu, H., & Xie, F. (2014) · Electromagnetic Biology and Medicine · doi:10.3109/15368378.2014.900507 · Cited by 52
“Following a DNA doublestrand break, serine residue 139 (ser-139) in the highly conserved carboxy-terminal SQE domain of H2AX is rapidly phosphorylated, generating histone gH2AX (Andrievski and Wilkins, 2009).”
BackgroundMay, M. S., Brand, M., Wuest, W., Anders, K., Kuwert, T., Prante, O., Schmidt, D., Maschauer, S., Semelka, R. C., Uder, M., et al. (2012) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2201-1 · Cited by 52
“5 h after (137)Cs irradiation with doses up to 10 Gy in an in vitro study design and concluded that the relatively quick lifetime kinetics of γ-H2AX foci limit its suitability for biodosimetry [18].”
BackgroundValdiglesias, V., Laffón, B., Pásaro, E., & Méndez, J. (2011) · Journal of Toxicology and Environmental Health · doi:10.1080/15287394.2011.582026 · Cited by 47
“In conclusion, our results showed that OA induced MN formation, both directly and indirectly, in all cell types tested, but DSB only occurred in HepG2 cells.”
BackgroundInfluentialTurner, H. C., Shuryak, I., Taveras, M., Bertucci, A., Perrier, J. R., Chen, C., Elliston, C. D., Johnson, G. W., Smilenov, L. B., Amundson, S. A., et al. (2015) · Radiation Research · doi:10.1667/rr13860.1 · Cited by 50
Phan, N., Lisio, M. D., Parise, G., & Boreham, D. R. (2012) · Radiation Research · doi:10.1667/rr2532.1 · Cited by 43
“However, the lack of difference may be partly due to the dose detection limit of the flow cytometry-based c-H2AX assay (73, 74, 78, 79).”
BackgroundNakamura, A., Suzuki, M., Redon, C. E., Kuwahara, Y., Yamashiro, H., Abe, Y., Takahashi, S., Fukuda, T., Isogai, E., Bonner, W. M., et al. (2017) · Radiation Research · doi:10.1667/rr14630.1 · Cited by 40
Fenech, M. F. (2011) · Radiation Measurements · doi:10.1016/j.radmeas.2011.01.016 · Cited by 34
The Application of Imaging Flow Cytometry to High-Throughput Biodosimetry
Wilkins, R. C., Rodrigues, M. A., & Beaton-Green, L. A. (2017) · Genome Integrity · doi:10.4103/2041-9414.198912 · Cited by 34
“As the DSBs repair, the γH2AX foci start to dephosphorylate rapidly in the first 24 h, approaching baseline values within a few days.[10,12] This rapidly changing response makes it difficult to determine the dose received with accuracy.”
BackgroundSelf-citationViau, M., Testard, I., Shim, G., Morat, L., Normil, M. D., Hempel, W. M., & Sabatier, L. (2015) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2015.05.009 · Cited by 32
Horn, S., Barnard, S. G. R., Brady, D., Prise, K. M., & Rothkamm, K. (2013) · Radiation Research · doi:10.1667/rr13342.1 · Cited by 31
“Furthermore, certain lymphocyte subsets, specifically B-cells, tend to display greater levels of radiation-induced apoptosis than T-cells (22) and it has been suggested radiation induced DSBs are heterogeneous between subsets (23).”
BackgroundCandidate protein biomarkers as rapid indicators of radiation exposure
Horn, S., & Rothkamm, K. (2011) · Radiation Measurements · doi:10.1016/j.radmeas.2011.02.001 · Cited by 30
Wei, W., He, J., Wang, J., Ding, N., Wang, B., Lin, S., Zhang, X., Hua, J., Li, H., & Hu, B. (2017) · Radiation Research · doi:10.1667/rr14702.1 · Cited by 31
Chaurasia, R. K., Bhat, N. N., Gaur, N., Shirsath, K. B., Desai, U. N., & Sapra, B. K. (2021) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2021.503354 · Cited by 32
-H2AX level in peripheral blood lymphocytes as a risk predictor for bladder cancer
Fernández, M. I., Gong, Y., Ye, Y., Lin, J., Chang, D. W., Kamat, A. M., & Wu, X. (2013) · Carcinogenesis · doi:10.1093/carcin/bgt270 · Cited by 31
“PBLs have been used as a surrogate tissue in several studies evaluating DNA damage and can be considered as the current standard (8,14,16,20,21).”
MethodResultInfluentialIs cardiac magnetic resonance imaging causing DNA damage?
Knuuti, J. M., Saraste, A., Kallio, M. J., & Minn, H. R. I. (2013) · European Heart Journal · doi:10.1093/eurheartj/eht214 · Cited by 29
Raavi, V., Gnanasekaran, T. S., Bhavani, M., Kumar, A., Alok, A., Karthik, K., Kalra, N., Vijayalakshmi, J., Paul, S. F. D., Chaudhury, N. K., et al. (2015) · Cytometry Part A · doi:10.1002/cyto.a.22729 · Cited by 28
“This is in agreement with previous studies that showed a linear dose response for lymphocytes and lymphocytes subsets (CD4, CD8, CD19) up to 10 Gy (31).”
ResultWerbrouck, J., Duprez, F., Neve, W. D., & Thierens, H. (2010) · International Journal of Radiation Biology · doi:10.3109/09553002.2010.518213 · Cited by 33
Riecke, A., Ruf, C. G., & Meineke, V. (2010) · Health Physics · doi:10.1097/hp.0b013e3181b97306 · Cited by 26
“8) Andrievski and Wilkins (2009).”
Multiple CT Scans Extend Lifespan by Delaying Cancer Progression in Cancer-Prone Mice
Lemon, J. A., Phan, N., & Boreham, D. R. (2017) · Radiation Research · doi:10.1667/rr14575.1 · Cited by 25
Hill, M. A., O'Neill, P., & McKenna, W. G. (2016) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jew163 · Cited by 27
“In general though the sensitivity of this approach is lower than that achieved by scoring individual foci, in part due to background foci intensity having a wider inter-individual variability.(42,43) As a result, this technique does not maintain the level of sensitivity required to be used as a biodosimeter of ionizin…”
ResultDNA damage in lymphocytes induced by cardiac CT and comparison with physical exposure parameters
Fukumoto, W., Ishida, M., Sakai, C., Tashiro, S., Ishida, T., Nakano, Y., Tatsugami, F., & Awai, K. (2016) · European Radiology · doi:10.1007/s00330-016-4519-8 · Cited by 27
Zwicker, F., Swartman, B. J., Sterzing, F., Major, G., Weber, K.-J., Huber, P., Thieke, C., Debus, J., & Herfarth, K. K. (2011) · Radiation Oncology · doi:10.1186/1748-717x-6-62 · Cited by 24
“Flow cytometry has also been performed in order to measure delivered dose by gH2AX stain [16], however, in our case it didn’t seem appropriate: The intensity of the gamma-H2AX foci varied and could have led to errors while measuring the background level of fluorescence.”
BackgroundMeasurement of H2AX Phosphorylation as a Marker of Ionizing Radiation Induced Cell Damage
Muslimović, A., Johansson, P., & Hammarste, O. (2012) · InTech eBooks · doi:10.5772/33257 · Cited by 27
“2007) and in some subsets of lymphocytes (Andrievski and Wilkins 2009).”
InfluentialScreening of Pesticides with the Potential of Inducing DSB and Successive Recombinational Repair
Suárez-Larios, K., Salazar, A. M., & Montero-Montoya, R. D. (2017) · Journal of Toxicology · doi:10.1155/2017/3574840 · Cited by 25
Zhao, L., Chang, D. W., Gong, Y., Eng, C., & Wu, X. (2017) · DNA repair · doi:10.1016/j.dnarep.2017.03.001 · Cited by 22
Ionizing Radiation–Induced γ-H2AX Activity in Whole Blood Culture and the Risk of Lung Cancer
He, Y., Gong, Y., Lin, J. M., Chang, D. W., Gu, J. H., Roth, J. A., & Wu, X. (2013) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-12-0794 · Cited by 24
“with a modification of a previously described protocol (35).”
Flow cytometric detection of gamma-H2AX to evaluate DNA damage by low dose diagnostic irradiation
Khan, K., Tewari, S., Awasthi, N. P., Mishra, S. P., Agarwal, G. R., Rastogi, M., & Husain, N. (2018) · Medical Hypotheses · doi:10.1016/j.mehy.2018.03.016 · Cited by 23
A deep learning model (FociRad) for automated detection of γ-H2AX foci and radiation dose estimation
Wanotayan, R., Chousangsuntorn, K., Petisiwaveth, P., Anuttra, T., Lertchanyaphan, W., Jaikuna, T., Jangpatarapongsa, K., Uttayarat, P., Tongloy, T., Chousangsuntorn, C., et al. (2022) · Scientific Reports · doi:10.1038/s41598-022-09180-2 · Cited by 21
“However, this time point was within the window of peak γ-H2AX responses (between 30 min and 2 h) 11,85 .”
BackgroundMethodWang, Z., Hu, H., Hu, M., Zhang, X., Wang, Q., Qiao, Y., Liu, H., Shen, L., Zhou, P., & Chen, Y. (2014) · Radiation and Environmental Biophysics · doi:10.1007/s00411-014-0530-0 · Cited by 20
“…of Radiation Medicine, 27 Taiping Road, Beijing 100850, China e-mail: zhoupk@nic.bmi.ac.cn Y. Chen e-mail: yingchen_29@163.com Q. Wang Beijing Consulting Centre of Biomedical Statistics, 27 Taiping Road, Beijing 100850, China (Hamasaki et al. 2007; Horn et al. 2011; Andrievski and Wilkins 2009).”
BackgroundMethodResultInfluentialMeade, A. D., Maguire, A., Bryant, J., Cullen, D., Medipally, D., White, L., McClean, B., Shields, L., Armstrong, J., Dunne, M., et al. (2018) · International Journal of Radiation Biology · doi:10.1080/09553002.2018.1451006 · Cited by 20
A Biomarker Panel of Radiation-Upregulated miRNA as Signature for Ionizing Radiation Exposure
Song, M. S., Xie, D., Gao, S., Bai, C., Zhu, M., Guan, H., & Zhou, P. (2020) · Life · doi:10.3390/life10120361 · Cited by 19
Turinetto, V., Pardini, B., Allione, A., Fiorito, G., Viberti, C., Guarrera, S., RUSSO, A. E., Anglesio, S. M., Redda, M. G. R., Casetta, G., et al. (2015) · Molecular Carcinogenesis · doi:10.1002/mc.22431 · Cited by 18
“The discrepancy of our results with those observed in [38] could be attributed to the different cultures employed (whole blood and cryopreserved lymphocytes) or to inter and intra-individual differences in the relative abundance of the different subpopulations of lymphocytes (as observed by [39]).”
Wanotayan, R., Wongsanit, S., Boonsirichai, K., Sukapirom, K., Buppaungkul, S., Charoenphun, P., Songprakhon, P., Jangpatarapongsa, K., & Uttayarat, P. (2022) · PLoS ONE · doi:10.1371/journal.pone.0265643 · Cited by 16
“Variation in γ-H2AX expression among individuals at the same absorbed dose observed by flow cytometry analysis [16,20] and the kinetic disappearance of γ-H2AX expression from its peak to baseline within 24 h observed by both flow cytometry and foci counting [1,4,6,18,22] have been previously reported.”
BackgroundMethodInfluentialLymphocyte subsets and their H2AX phosphorylation in response to in vivo irradiation in rats
Zárybnická, L., Vávrová, J., Havelek, R., Tichý, A., Pejchal, J., & Šinkorová, Z. (2012) · International Journal of Radiation Biology · doi:10.3109/09553002.2012.721050 · Cited by 16
“H2AX phosphorylation and multicolour immunophenotyping were assessed by using a modifi cation of a previously described protocol (Andrievski and Wilkins 2009).”
MethodRisk Assessment of Esophageal Adenocarcinoma Using γ-H2AX Assay
Xu, E., Gong, Y., Gu, J. H., Jie, L., Ajani, J. A., & Wu, X. (2013) · Cancer Epidemiology Biomarkers & Prevention · doi:10.1158/1055-9965.epi-13-0485 · Cited by 16
“tained for approximately 1 hour before starting to decrease with time (21, 33).”
BackgroundZwicker, F., Swartman, B. J., Roeder, F., Sterzing, F., Hauswald, H., Thieke, C., Weber, K.-J., Huber, P. E., Schubert, K., Debus, J., et al. (2014) · Journal of Radiation Research · doi:10.1093/jrr/rru096 · Cited by 15
“The method used for in vivo measurement of dose distribution within a patients’s lymphocytes by detecting gamma-H2AX foci (and the potential limitations of this method) have been discussed earlier [2], whereas subsequent articles [6, 19–28] have considered what determines the presence of the lymphocytes in body tissue…”
MethodFaßhauer, M., Krüwel, T., Zapf, A., Stahnke, V., Rave‐Fränk, M., Staab, W., Sohns, J. M. S., Steinmetz, M., Unterberg‐Buchwald, C., Schuster, A., et al. (2017) · European Radiology · doi:10.1007/s00330-017-5056-9 · Cited by 14
“On the other hand, most studies also suggested that most DNA repair mechanisms involving γH2AX occur in the very first hours after exposure to potentially harmful agents [12, 37, 45, 46].”
BackgroundPhase 0 Radiopharmaceutical–Agent Clinical Development
Kunos, C. A., Rubinstein, L., Capala, J., & McDonald, M. A. (2020) · Frontiers in Oncology · doi:10.3389/fonc.2020.01310 · Cited by 14
Zhou, S., Li, Y., He, L., Chen, M., Li, W., Xiao, T., Guan, J., Qi, Z., Wang, Q., Li, S., et al. (2022) · Stem Cell Research & Therapy · doi:10.1186/s13287-022-03162-x · Cited by 13
A portable microfluidic fluorescence spectrometer device for γ-H2AX-based biological dosimetry
Pope, I., Barber, P. R., Horn, S., Ainsbury, E. A., Rothkamm, K., & Vojnovic, B. (2011) · Radiation Measurements · doi:10.1016/j.radmeas.2011.02.004 · Cited by 13
“Notably, however, considerable variation in radiation-induced g-H2AX levels has been reported between different leukocyte and lymphocyte subsets (see e.g. Andrievski and Wilkins, 2009).”
BackgroundWang, J., Yin, L., Zhang, J., Zhang, Y., Zhang, X., Ding, D., Gao, Y., Li, Q., & Chen, H. (2016) · Radiation and Environmental Biophysics · doi:10.1007/s00411-016-0653-6 · Cited by 12
“Our results are similar to previous reports on the dose–response curves in human lymphocytes exposed to IR (Andrievski and Wilkins 2009; Belyaev 2010; Horn et al. 2011; Rothkamm et al. 2013).”
BackgroundResultInfluentialInvestigating γ H2AX as a Biomarker of Radiosensitivity Using Flow Cytometry Methods
Beaton-Green, L. A., Marro, L., Malone, S. C., Samiee, S., Grimes, S., Malone, K., & Wilkins, R. C. (2013) · ISRN Radiology · doi:10.5402/2013/704659 · Cited by 12
“A study by Andrievski and Wilkins in 2009 [11] noted that lymphocyte subsets CD4, CD8, and CD19 had varied γH2AX responses and proposed that investigating the in vitro response in lymphocyte subsets, CD19 in particular, might be proved to be a more sensitive assay.”
BackgroundSelf-citationSerum microRNA as noninvasive indicator for space radiation
Wei, W.-J., Wang, J., He, J., & Xie, X. (2018) · Acta Astronautica · doi:10.1016/j.actaastro.2018.07.038 · Cited by 11
Early Biomarkers Associated with P53 Signaling for Acute Radiation Injury
Li, W., Zhou, S., Jia, M., Li, X., Li, L., Wang, Q., Qi, Z., Zhou, P., Li, Y., & Wang, Z. (2022) · Life · doi:10.3390/life12010099 · Cited by 12
Dose-response relationship of γ-H2AX foci induction in human lymphocytes after X-rays exposure
Mandina, T., Lefèvre, S.-H., Voisin, P., Mesa, J. E. G., Boada, A. I. L., Romero, I., García, O., Voisin, P., & Roy, L. (2011) · Radiation Measurements · doi:10.1016/j.radmeas.2011.05.014 · Cited by 11
Establishment and validation of surface model for biodosimetry based on γ-H2AX foci detection
López, J. S., Pujol-Canadell, M., Puig, P., Ribas, M., Carrasco, P., Armengol, G., & Barquinero, J. F. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2022.1998706 · Cited by 11
Radiation dose estimation with time-since-exposure uncertainty using the $$\gamma $$-H2AX biomarker
Młynarczyk, D., Puig, P., Armero, C., Gómez‐Rubio, V., Barquinero, J. F., & Pujol-Canadell, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-24331-1 · Cited by 10
Fieber, L. A., Greer, J. B., Guo, F., Crawford, D. L., & Rein, K. S. (2012) · Toxicological & Environmental Chemistry Reviews · doi:10.1080/02772248.2012.730199 · Cited by 10
Comparison of Individual Radiosensitivity to γ-Rays and Carbon Ions
Shim, G., Normil, M. D., Testard, I., Hempel, W. M., Ricoul, M., & Sabatier, L. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00137 · Cited by 10
DosiKit, a New Portable Immunoassay for Fast External Irradiation Biodosimetry
Bensimon, J., Valente, M., Altmeyer‐Morel, S., Bettencourt, C., Bouvet, S., Cosler, G., Desangles, F., Drouet, M., Entine, F., Hérodin, F., et al. (2017) · Radiation Research · doi:10.1667/rr14760.1 · Cited by 10
“This is consistent with observations reported by other laboratories using global analysis techniques, such as flow cytometry or Western blotting, where the peak is also approximately 1–2 h postirradiation (39, 40).”
ResultSerum Proteins as New Biomarkers for Whole-Body Exposure to High- and Low-LET Ionizing Radiation
Wei, W., Bai, H., Feng, X., Hua, J., Long, K., He, J., Zhang, Y., Ding, N., Wang, J., & Zhou, H. (2020) · Dose-Response · doi:10.1177/1559325820914172 · Cited by 9
“Chromosomal aberration and g-H2AX foci are not sensitive to low dose of radiation and are easily influenced by the repair of DNA damage.(10,11) Therefore, new rapid, simple, and efficient biomarkers are urgently needed to makeup limitations or replace traditional biomarkers.”
BackgroundWei, W., Bai, H., Chen, Y., Zhang, T., Zhang, Y., Hua, J., He, J., Ding, N., Zhou, H., & Wang, J. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms222413476 · Cited by 9
“However, the detection processes of these biomarkers are time-consuming and complex [5,6].”
BackgroundBrix, G., Günther, E., Rößler, U., Endesfelder, D., Kamp, A., Beer, A. J., & Eiber, M. (2020) · EJNMMI Research · doi:10.1186/s13550-020-00625-1 · Cited by 9
The Gamma-H2AX Assay as a High Throughput Triage Tool: Comparison of Two Prototype Devices
Rothkamm, K., Horn, S., Pope, I., Barber, P. R., Barnard, S. G. R., Moquet, J., Idc., T., & Vojnovic, B. (2012) · Cited by 7
BPIFA2 as a Novel Early Biomarker to Identify Fatal Radiation Injury After Radiation Exposure
He, L., Zhou, S., Li, W., Wang, Q., Qi, Z., Zhou, P., Wang, Z., Chen, J., Li, Y., & Lin, Z. (2022) · Dose-Response · doi:10.1177/15593258221086478 · Cited by 7
“Thus, its application is greatly limited by such a short detection window.(15-17) In summary, the existing biodosimeterss cannot achieve timely detection at the accident sites without delicate instrument.”
BackgroundDevelopment of high-throughput systems for biodosimetry
Wilkins, R. C., & Beaton-Green, L. A. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad060 · Cited by 6
“As the number of gamma-H2AX foci increases with dose, so does the overall intensity of the fluorescently labelled gamma-H2AX (19, 50, 51) .”
BackgroundSelf-citationHavelek, R., Řezáčová, M., Šinkorová, Z., Zárybnická, L., Tichý, A., & Vávrová, J. (2011) · Acta Veterinaria Brno · doi:10.2754/avb201180010113 · Cited by 6
Manivannan, B., Kuppusamy, T., Venkatesan, S., & Venkatachalam, P. (2017) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2017.10.031 · Cited by 6
Entine, F., Etzol, J. B., Bettencourt, C., Dondey, M., Michel, X., Gagna, G., Gellie, G., Corre, Y., Ugolin, N., Chevillard, S., et al. (2018) · Health Physics · doi:10.1097/hp.0000000000000863 · Cited by 6
Havelek, R., Řezáčová, M., Šinkorová, Z., Zárybnická, L., Pejchal, J., & Vávrová, J. (2011) · Journal of Applied Biomedicine · doi:10.2478/v10136-011-0007-2 · Cited by 6
“Andrievski and Wilkins (2009) compared the H2AX phosphorylation in different lymphocyte subpopulations after in vitro irradiation (0–10 Gy) of lymphocytes isolated from the peripheral blood.”
BackgroundRödiger, S., Liefold, M., Ruhe, M., Reinwald, M., Beck, E. P., & Deckert, P. M. (2018) · Journal of Laboratory and Precision Medicine · doi:10.21037/jlpm.2018.04.10 · Cited by 6
“Their quantitation may therefore be useful for monitoring cancer therapies, both with regard to their effectiveness as to adverse events (8,9).”
BackgroundEstablished and Emerging Methods of Biological Dosimetry
Rothkamm, K., & Lloyd, D. (2014) · Elsevier eBooks · doi:10.1016/b978-0-444-53632-7.00814-5 · Cited by 6
Farhadi, S., Bahreyni-Toossi, M.-T., Zafari, N., Khademi, S., Darbandi, M. S., & Azimian, H. (2022) · Mutation Research/Genetic Toxicology and Environmental Mutagenesis · doi:10.1016/j.mrgentox.2022.503528 · Cited by 5
Bai, H., Zhang, T., Wang, J., Hua, J., & Wei, W. (2021) · Acta Astronautica · doi:10.1016/j.actaastro.2021.05.047 · Cited by 5
Hassan, E. M., Puzantian, B., Mayenburg, J. M., Li, M., Rashid, M., Wilkins, R. C., & Beaton-Green, L. A. (2025) · International Journal of Radiation Biology · doi:10.1080/09553002.2025.2536108 · Cited by 4
“Thus, even with the rapid kinetic decay of the signal, the γ-H2AX assay could provide rapid, same day, indication of IR exposure in triage situations (Andrievski and Wilkins 2009; Viau et al. 2015; Raavi et al. 2021).”
Self-citationRegulation of Circulating miR-342-3p Alleviates the Radiation-Induced Immune System Injury
Wei, W.-J., Bai, H., Zhang, T., Cai, S., Zhou, Y., Liu, M., Zhang, Y., Chen, Y., Hua, J., He, J., et al. (2023) · Radiation Research · doi:10.1667/rade-23-00125.1 · Cited by 4
“Traditional biomarkers or biological dosimeters mainly focused on cell-target assays, such as chromosome aberration, micronuclei formation and DNA damage-related proteins’ foci, etc. ( 20 – 23 ).”
BackgroundAchel, D. G., Serafin, A. M., & Akudugu, J. (2016) · Radiation and Environmental Biophysics · doi:10.1007/s00411-016-0654-5 · Cited by 4
“This is in agreement with several studies that established that individuals differ widely in cellular responses to ionising radiation (Andrievski and Wilkins 2009; Hamasaki et al. 2007; Horn et al. 2011; Ismail et al. 2007; Viau et al. 2015).”
ResultCaptain Tardigrade and Its Shield to Protect DNA
Cantara, S., Regoli, T., & Ricci, C. (2025) · DNA · doi:10.3390/dna5020027 · Cited by 3
Melo, A. M., Maher, S. G., O’Leary, S. M., Doherty, D. G., & Lysaght, J. (2020) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.12.016 · Cited by 3
“Analysis of lymphocyte subtypes showed that CD4 and CD8 T cells and B cells display similar kinetics of c-H2AX expression, but CD4 and CD8 T cells express more c-H2AX than B cells [27].”
BackgroundEvaluation of γ-H2AX foci distribution among different peripheral blood mononucleated cell subtypes
López, J. S., Pujol-Canadell, M., Puig, P., Armengol, G., & Barquinero, J. F. (2023) · International Journal of Radiation Biology · doi:10.1080/09553002.2023.2187480 · Cited by 4
COHERE – strengthening cooperation within the Canadian government on radiation research
Chauhan, V., Leblanc, J. E., Sadi, B. B. M., Burtt, J. J., Sauvé, K., Lane, R. S. D., Randhawa, K. A., Wilkins, R. C., & Quayle, D. (2021) · International Journal of Radiation Biology · doi:10.1080/09553002.2021.1941379 · Cited by 2
“…(FISH), micronuclei in binucleated cells, and DNA double-strand break induction as measured by cH2AX foci formation, all provide mechanistic information that feeds into the radiation response pathways (Andrievski and Wilkins 2009; McNamee et al. 2009; Flegal et al. 2012; Beaton-Green et al. 2016).”
BackgroundSelf-citationCalibrators for Clinical Measurements of Phosphorylated H2AX in Patient Cells by Flow Cytometry
Muslimović, A. (2012) · The Open Clinical Chemistry Journal · doi:10.2174/1874241601205010033 · Cited by 2
Predictive Biomarkers of Cellular Radiosensitivity for Clinical Radiotherapy Treatment
White, L. (2016) · Arrow - TU Dublin (Technological University Dublin) · doi:10.21427/d70w2x · Cited by 2
Plasma levels of serum amyloid A1 and mortality after exposure to high-dose radiation
Klokov, D. Y. (2020) · Annals of Translational Medicine · doi:10.21037/atm.2020.03.172 · Cited by 2
“Alternative methods for reconstructing unknown radiation dose have been explored (13), including those based on a widely known marker of DNA double-strand breaks γH2AX (14), gene expression changes (14) and several other biomarkers of exposure to radiation.”
MethodActivities of ISO Working Group 18: Biological and Physical Retrospective Dosimetry
Wilkins, R. C., Ainsbury, E. A., Alsbeih, G., Balajee, A. S., Blakely, W. F., Deminge, M., Endesfelder, D., Fenech, M. F., Grégoire, E., Herrold, J., et al. (2025) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2025.10095 · Cited by 1
Self-citationAbraham, C. B., Dadgar, S., Floriano, W. B., Campbell, M., & Curiel, L. (2022) · Journal of Modern Physics · doi:10.4236/jmp.2022.136047
Okunola, H. L., Shuryak, I., Repin, M., Wu, H., Santella, R. M., Terry, M. B., Turner, H. C., & Brenner, D. J. (2023) · Research Square · doi:10.21203/rs.3.rs-3093360/v1
Metadata
- Authors
- Andrievski, A., & Wilkins, R. C.
- Affiliations
- Carleton University (CA)
- Health Canada (CA)
- Corresponding author
- Wilkins, Ruth C.
- ORCID
- Wilkins, Ruth C.
- Venue
- International Journal of Radiation Biology
- Publisher
- Informa UK Limited
- Published
- 2009-01
- Volume
- 85
- Issue
- 4
- Pages
- 369-376
- ISSN
- 0955-3002 (ISSN-L)
- 1362-3095
- OpenAlex
- W2038108398
- Cited by
- 107
- References
- 29
- Citations by year
- 2026: 2 · 2025: 4 · 2023: 5 · 2022: 9 · 2021: 5 · 2020: 7 · 2018: 6 · 2017: 11 · 2016: 7 · 2015: 9 · 2014: 4 · 2013: 10 · 2012: 10
- FWCI
- 7.05
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Radiation Biology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Health Research Board
- Health Canada
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Effects of Radiation Exposure
- Physical Sciences › Physics and Astronomy › Radiation › Radiation Therapy and Dosimetry
- Life Sciences › Agricultural and Biological Sciences › Food Science › Radiation Effects and Dosimetry
- Keywords
- γH2AX, biological dosimetry, lymphocyte subsets, CD4+ T cells, CD8+ T cells, B cells, whole blood flow cytometry, cesium-137 irradiation, dose-response relationship, interindividual variability
- MeSH terms
- Adult, Animals, Cells, Cultured, Dose-Response Relationship, Radiation, Female, Flow Cytometry, Histones, Humans, Lymphocytes, Male, Middle Aged, Phosphorylation, Radiometry, Time Factors, Lymphocyte Subsets, Mass Casualty Incidents
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.