Fireside corrosion and deposition on heat exchangers in biomass combustion systems
Open accessAbstract
To address climate change, power plants need to switch to greener fuels. One possible fuel is biomass; a carbon neutral/low carbon fuel. However biomasses’ chemistries are both different from coal’s and vary depending on their sources, containing unique levels of the trace elements (e.g., Cl and S) capable of altering the degradation of heat-exchangers. As such, an understanding of the effects of these variations on fireside corrosion is needed. Laboratory testing exposed alloys T91 and TP347HFG in a simulated agricultural product combustion environment at 600°C (up to 1000h; 100h cycles). Three different deposits mixtures were investigated (comprised of KCl, K2SO4, Na2SO4, CaSO4 indifferent percentages) mimicking accelerated corrosion from different biomasses. Corrosion behaviour was found to be dependant on both alloy and deposit chemistries, with the two materials showing different responses. The deposit with lowest KCl showed lowest corrosion damage, while the highest KCl deposit showed more aggressive behaviour.
Overview
CoChat Summary
TL;DR
Laboratory fireside corrosion tests exposed T91 and TP347HFG to a simulated agricultural-residue biomass combustion gas at 600°C for up to 1000 h with three synthetic deposits. Corrosion depended on both alloy and deposit chemistry, with the lowest-KCl deposit causing least damage and higher-KCl deposits more aggressive.
Key findings
- After 1000 h, median metal change for the lowest-KCl deposit D1 was -74 μm for T91 and -45 μm for TP347HFG; D6 gave -260 μm (T91) and -170 μm (TP347HFG), and D8 gave -200 μm (T91) and -262 μm (TP347HFG).
- The conclusions state T91 suffered higher damage from D8 while 347HFG showed higher damage from D6; the dimensional metrology text instead reports D6 had more impact on T91 and D8 on 347HFG.
- SEM/EDS showed 347HFG underwent internal/intergranular attack, with greater penetration for D1, linked to D1’s lower chlorine level and K/Na/Ca sulphate content facilitating Cl penetration; 347-D6 pitting was linked to higher Cl content.
- T91 showed no internal attack for D1 but a porous, detached scale; internal attack was reported for D6 and D8, which contain higher Cl levels.
Methods
- Two alloys were tested: ferritic T91 and austenitic TP347HFG; segment specimens were about 15 mm × 15 mm × 5 mm with a UK 600 grit finish.
- Corrosion tests used a controlled-atmosphere vertical furnace at 600°C for 1000 h total, cycled every 100 h with deposit recoat; gas simulated APR combustion exhaust at 1100°C (N2 70.3, O2 6.2, CO2 11.8 mol%; SO2 96 ppm, HCl 53 ppm, H2O 11.6), with dry gas at 100 sccm and water at 18.4 sccm. Deposits were D1 (KCl 30, K2SO4 20, Na2SO4 20, CaSO4 30 mole%), D6 (KCl 71, K2SO4 29), and D8 (KCl 67, K2SO4 33); 20 mg deposit was applied per sample per cycle.
- Dimensional metrology after 200, 500, and 1000 h produced cumulative probability distributions of metal change and sound metal change, subtracting gas-only damage; SEM/EDS examined scale/deposit microstructure and elemental composition. Typical dimensional metrology errors were about 3–5 μm.
Limitations
- Stated: the gas composition simulated exhaust at 1100°C, but tests were at 600°C; at equilibrium this gas would not be expected to have S-species in the gaseous phase, only condensed phases, which is not representative of the postcombustion scenario.
- Evident: the provided text is fragmented and contains an apparent inconsistency between the conclusions and dimensional metrology on which deposit is more aggressive for T91 versus 347HFG.
- Evident: the study uses accelerated laboratory deposit-recoat testing rather than plant exposure, so the reported damage rates are not direct field measurements.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
6 Valid · 3 Not valid · 10 Not checked · 47 Own results and interpretations
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“It can be observed that there is overlap in the Na, K and S maps (Figure 7 and Figure 11), which could suggest the formation of K 3 Na(SO 4 ) 2 with low melting point [15].”
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Dimensional metrology
What the sources say
- Could not verifycites [15] sourceExperimental — accuracy not yet measured
The Introduction identifies the alloys studied as Sanicro 25 and IN740, and the Results and discussion describe their oxide scales and EDX maps, not 347HFG-D1 after 500 h. Searches for K3Na(SO4)2, sodium–potassium sulfate, and a low melting point found no passage supporting the proposed compound or its melting behavior. (LLM, conf=0.76)
hedgedstates a possible causeSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
The cited sources that could be checked couldn’t confirm or dispute this claim.
In the paper
“The availability of chlorides would be influenced by the S/Cl ratio, which determine the eutectic melt fraction of the deposit [15].”
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Dimensional metrology
What the sources say
- Could not verifycites [15] sourceExperimental — accuracy not yet measured
The Introduction discusses KCl deposits and the possible role of chlorine in alloy attack, but does not relate chloride availability to an S/Cl ratio. Searches for “S/Cl,” “eutectic,” and deposit melt fraction found no passage establishing the claimed relationship in our copy. (LLM, conf=0.74)
hedgedstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Could not verify
Every source the paper cites for this claim was checked and supports it.
In the paper
“These differences in chemical composition will alter the chemistries of the respective flue gases, and therefore the chemistry and quantity of any species condensing onto the heatexchanger surfaces as deposits [10].”
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Introduction
What the sources say
- Supportedcites [10] source
Section 2 ("Coal" subsection) states that biomass fuels differ in K, Cl, S and silica content, that these elements are readily volatilized during combustion, forming vapor-phase chloride compounds/ions that then "deposit and form a sticky layer on the heat exchanger or heat transfer surfaces," and that low-S feed increases Cl deposition via the sulphation equilibria — i.e., fuel composition changes the gaseous species present. Section 5 ("Mechanesm and Chemistry of Ash Deposition") closes the chain: condensation of volatile inorganic species is "the principle mechanism for the formation of convective pass fouling ... in particular when biomass fuels contain high levels of volatile species," and gas-phase K speciation (KCl/KOH vs K2SO4, Figure 3) plus vapor concentration determine how much nucleates/condenses. The citing sentence is a paraphrase of this content; only the phrase "flue gas chemistries" is the authors' own wording. (LLM, conf=0.86)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“This is due to the ability of Cl to react via an ion exchange mechanism [15] that enhances corrosion damage.”
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Introduction
What the sources say
- Partly supportedcites [15] sourceExperimental — accuracy not yet measured
The Introduction says Cl could change the alloy’s attack mechanism, and the Results and discussion report substantial corrosion damage in KCl exposures. But the mechanism discussed there is grain-boundary attack and possible diffusion-cell behaviour; our copy does not identify ion exchange as the mechanism. (LLM, conf=0.86)
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“Due to their different origins, these different categories of fuels exhibit different chemical compositions, especially with regards to trace elements, such as K, Cl, S, Na, and Ca [11,12].”
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Introduction
What the sources say
- Partly supportedcites [11] sourceExperimental — accuracy not yet measured
Our copy supports the operational core of the claim: the Colmac Energy section (pp. 84-85) records that the plant adjusted its fuel mix 'to reduce problems such as corrosion and fouling caused by potassium, sodium, and other elements in the biomass fuels'; the Wheelabrator Shasta/McNeil fuel-blend discussion (p. 37) attributes almond-shell ash's low melting point to 'high potassium content'; the Bay Front environmental section (p. 14) contrasts wood's inherently low sulfur and fuel-bound nitrogen with coal; and the Tacoma lessons (p. 77) tie chlorine and metals specifically to RDF. So the source does show that different biomass/waste fuel categories carry different inorganic elements with different consequences. What it does not support is the claim's framing as a chemical-composition comparison across fuel categories driven by 'different origins', and the specific element list: calcium (Ca) is never reported as a fuel constituent anywhere in our copy (calcium appears only as injected lime/limestone for SO2 control, pp. 63, 44ff), and the report gives no elemental composition data for the fuel categories it lists (pp. 51, 84). This is an engineering 'lessons learned' report, not a fuel-chemistry study, so it backs K, Na, Cl and S anecdotally but not the general compositional statement as printed. (LLM, conf=0.68)
- Not matchedcites [12] Wilen C, 1996
Couldn’t be matched to a paper in Crossref, so it can’t be checked.
plainstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Partly supported
26 more claims · 1 with their cited sources checked
Create a free account to see all 66 claims and every source verdict.
- It may state two separate claims as one. 31
- Probably not a substantial claim. 6
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated major: it would touch a result — a value a result rests on, reported and recomputed p-values on opposite sides of the significance level, two passages that conflict with no sign which is right, or a cited work retracted before this paper was published.
In the paper
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Conclusions
“It also showed that the two alloys react differently to the different deposits, with T91 suffering a higher damage from deposit D8, while 347HFG showed higher damage for deposit D6.”
§ Fireside corrosion and deposition on heat exchangers in biomass combustion systems > Dimensional metrology
“It appears that the deposit D6 has more impact over time on T91 steel leading to a higher metal and sound metal change (-260 μm and -270 μm, respectively), while D8 has more impact on 347HFG for both metal and sound metal change (-262 μm and -275 μm, respectively).”
Citations
Cites
(2014) · Climate Change 2013 – The Physical Science Basis · doi:10.1017/cbo9781107415324.004 · Cited by 23,880
Co-firing of coal and biomass fuel blends
Sami, M., Annamalai, K., & Wooldridge, M. (2001) · Progress in Energy and Combustion Science · doi:10.1016/s0360-1285(00)00020-4 · Cited by 838
The implications of chlorine-associated corrosion on the operation of biomass-fired boilers
Nielsen, H. P., Frandsen, F. J., Dam-Johansen, K., & Baxter, L. L. (2000) · Progress in Energy and Combustion Science · doi:10.1016/s0360-1285(00)00003-4 · Cited by 785 · cited 1×
“Previous studies have assessed the role of K, Na and Ca on the corrosion mechanisms of SS304L at 600°C [18], showing how the CaCl2 had a lesser impact on corrosivity as compared to Na and K chloride compounds.”
BackgroundHot corrosion of materials: a fluxing mechanism?
Rapp, R. A. (2002) · Corrosion Science · doi:10.1016/s0010-938x(01)00057-9 · Cited by 529
Deposition and high temperature corrosion in a 10 MW straw fired boiler
Michelsen, H. P., Frandsen, F., Dam-Johansen, K., & Larsen, O. H. (1998) · Fuel Processing Technology · doi:10.1016/s0378-3820(97)00062-3 · Cited by 258 · cited 1×
“The fireside corrosion of power plant heat exchangers is known to be very dependent on the combustion environment chemistry, as already shown [13,14], with the corrosion damage exhibiting a well-known ‘bell shape’ distribution as function of metal surface temperature [13,14].”
BackgroundDiffusion Cells and Chemical Failure of MCrAlY Bond Coats in Thermal-Barrier Coating Systems
Evans, H. E., & Taylor, M. P. (2001) · Oxidation of Metals · doi:10.1023/a:1010369024142 · Cited by 188 · cited 1×
“A similar behaviour was reported in literature [35,36] and named as ‘diffusion cell’ behaviour.”
ResultAsh Deposition in Biomass Combustion or Co-Firing for Power/Heat Generation
Shao, Y., Wang, J., Preto, F., Zhu, J., & Xu, C. (2012) · Energies · doi:10.3390/en5125171 · Cited by 178 · cited 6×
“Challenges can arise from the use of such fuels, especially in regards to fireside corrosion of heat exchanger materials in power plants [10].”
BackgroundInfluentialAlkali Induced High Temperature Corrosion of Stainless Steel: The Influence of NaCl, KCl and CaCl2
Karlsson, S., Pettersson, J., Johansson, L. G., & Svensson, J. E. (2012) · Oxidation of Metals · doi:10.1007/s11085-012-9293-7 · Cited by 118 · cited 1×
“the effects of different deposits on the formation of K2 CrO4 on stainless steel could only confirm the presence of such compounds [19].”
BackgroundPettersson, J., Folkeson, N., Johansson, L.-G., & Svensson, J.-E. (2011) · Oxidation of Metals · doi:10.1007/s11085-011-9240-z · Cited by 117 · cited 3×
“It is anticipated from literature [15,17,20,21], that a mixed deposit chemistry will decrease the melting”
BackgroundFireside corrosion of superheaters: Effects of air and oxy-firing of coal and biomass
Syed, A. U., Simms, N. J., & Oakey, J. E. (2011) · Fuel · doi:10.1016/j.fuel.2011.03.010 · Cited by 117
Self-citation
Research works printed but not linked: 6
- 2010, Roadmap 2050:A practical guide to a prosperous
- Froggatt A, 2015, Deconstructing the European energy union: governance and 2030 goals
- Camarsa G, 2015, LIFE and climate change mitigation
- Wilen C, 1996, Kurkela espoo (Finland). energy production technologies]
- Grabke HJ, 1995, Guidelines for Methods of Testing and Research in High Temperature Corrosion EFC 14
- Cruchley S, 2016, Https, 33, 465
Cited by
Zheng, L., Jin, J., Zhang, R., Liu, Z., & Zhang, L. (2023) · Energy · doi:10.1016/j.energy.2023.126950 · Cited by 13
Yang, X., Xu, Y., Chen, W., Lu, J., Dang, Y., Huang, J., & Li, W. (2023) · CORROSION · doi:10.5006/4277 · Cited by 6
Joy, T., Mori, S., & Sumner, J. (2025) · Journal of Energy Storage · doi:10.1016/j.est.2025.115554 · Cited by 4
Self-citationUsman, A., Isern, L., Nicholls, J. R., Cordero-Cabrera, M. C., & Syed, A. U. (2025) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-025-11630-7 · Cited by 3
Synergetic mechanism between corn stalk biochar and coal pulping in coal-water slurry
Li, G., Mao, L., Zhang, L., Wu, Q., & Li, H. (2025) · Chinese Journal of Chemical Engineering · doi:10.1016/j.cjche.2025.03.011 · Cited by 2
Metadata
- Authors
- Mori, S., Sanusi, T., Simms, N., & Sumner, J.
- Affiliations
- Cranfield University (GB)
- Corresponding author
- Mori, Stefano
- Venue
- Materials at High Temperatures
- Publisher
- Informa UK Limited
- Published
- 2022-10-31
- Volume
- 40
- Issue
- 1
- Pages
- 36-47
- ISSN
- 0960-3409 (ISSN-L)
- 1878-6413
- OpenAlex
- W4308145562
- Cited by
- 8
- References
- 30
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 2 · 2023: 2
- FWCI
- 0.78
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Materials at High Temperatures (publishedVersion, cc-by)
- CERES (Cranfield University) (submittedVersion, cc-by)
- Funders
- BF2RA (28)
- Topics
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › High-Temperature Coating Behaviors
- Physical Sciences › Energy › Fuel Technology › Thermochemical Biomass Conversion Processes
- Physical Sciences › Engineering › Mechanical Engineering › High Temperature Alloys and Creep
- Keywords
- fireside corrosion, heat exchangers, biomass combustion, potassium chloride, potassium sulfate, sodium sulfate, calcium sulfate, agricultural biomass, high-temperature corrosion, power plant fuel
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (gpt-6-sol and qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fireside corrosion and deposition on heat exchangers in biomass combustion systems. https://app.cochat.ai/papers/10.1080/09603409.2022.2138007
- The paper
- Mori, S., Sanusi, T., Simms, N., & Sumner, J. (2023). Fireside corrosion and deposition on heat exchangers in biomass combustion systems. Materials at High Temperatures. https://doi.org/10.1080/09603409.2022.2138007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.