Central heating thermostat settings and timing: building demographics
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Crucial empirical data (currently absent in building energy models) on central heating demand temperatures and durations are presented. These data are derived from the first national survey of energy use in English homes and includes monitored temperatures in living rooms, central heating settings reported by participants, along with building, technical, and behavioural data. The results are compared with model assumptions with respect to thermostat settings and heating durations. Contrary to assumptions, the use of controls did not reduce average maximum living room temperatures or the duration of operation. Regulations, policies, and programmes may need to revise their assumptions that adding controls will reduce energy use. Alternative forms of heating control should be developed and tested to ascertain whether their use saves energy in real-world settings. Given the finding that detached houses are heated for longer, these dwellings should be particularly targeted in energy-efficiency retrofit programmes. Furthermore, social marketing programmes could use the wide variation in thermostat settings as the foundation of a ‘social norm’ programme aimed at reducing temperatures in ‘overheated’ homes. Finally, building energy models that inform energy policies require firmer foundations in real-world data to improve policy effectiveness. Greater coordination of data collection and management would make more data available for this purpose. Sont présentées ici des données empiriques critiques (actuellement absentes des modèles énergétiques des bâtiments) concernant les températures demandées et les durées d'utilisation du chauffage central. Ces données proviennent de la première enquête nationale sur l'utilisation de l’énergie dans les foyers anglais et comprennent les températures contrôlées dans les salles de séjour, les réglages du chauffage central indiqués par les participants, ainsi que des données comportementales, techniques et relatives aux immeubles. Les résultats sont comparés aux hypothèses des modèles en ce qui concerne le réglage des thermostats et les durées de chauffage. Contrairement aux hypothèses, l'utilisation de dispositifs de régulation n'a réduit ni les températures maximales moyennes dans les salles de séjour, ni la durée de fonctionnement. Il serait peut-être nécessaire que les réglementations, les politiques et les programmes révisent leurs hypothèses selon lesquelles le fait d'ajouter des dispositifs de régulation réduira l'utilisation d’énergie. D'autres formes de régulation du chauffage devraient être développées et testées afin de vérifier si leur utilisation économise de l’énergie dans des cadres de vie réels. Etant donné la constatation que les maisons individuelles sont chauffées pendant plus longtemps, ces logements devraient être particulièrement ciblés dans les programmes de mise aux normes visant un meilleur rendement énergétique. De plus, les programmes de marketing social pourraient utiliser les grandes variations dans le réglage des thermostats comme base d'un programme de « norme sociale » visant à réduire la température dans les logements « surchauffés ». Enfin, il est nécessaire que les modèles énergétiques des bâtiments, qui ont une influence sur les politiques énergétiques, soient plus fermement basés sur des données réelles afin d'améliorer l'efficacité de ces politiques. Une plus grande coordination dans la collecte et la gestion des données permettrait de disposer de davantage de données à cette fin. Mots clés: modèle énergétique des bâtiments, chauffage central, systèmes de contrôle, température demandée, commandes du chauffage domestique, demande énergétique, comportement des habitants, réglage des thermostats
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Constructive, Destructive, and Reconstructive Power of Social Norms
Schultz, P. W., Nolan, J. M., Cialdini, R. B., Goldstein, N. J., & Griskevicius, V. (2007) · Psychological Science · doi:10.1111/j.1467-9280.2007.01917.x · Cited by 3,643
Goyder, J., & de Vaus, D. A. (1987) · Canadian Journal of Sociology / Cahiers canadiens de sociologie · doi:10.2307/3340954 · Cited by 2,269
Fostering Sustainable Behavior: An Introduction to Community-Based Social Marketing
McKenzie‐Mohr, D. (1999) · Cited by 1,785
Crafting Normative Messages to Protect the Environment
Cialdini, R. B. (2003) · Current Directions in Psychological Science · doi:10.1111/1467-8721.01242 · Cited by 1,553
Thermal adaptation in the built environment: a literature review
Brager, G. S., & de Dear, R. J. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00053-4 · Cited by 1,483 · cited 1×
“(2008) , Nicol and Roaf (2005) , and Brager and de Dear (1998) note the huge variation in temperatures that individuals can find thermally comfortable, even within the same society.”
De Vaus, D. (2013) · Routledge eBooks · doi:10.4324/9780203501054 · Cited by 784 · cited 1×
“Firstly, in a study of home energy use, social desirability response bias may prompt householders to report lower thermostat settings than they actually maintain (de Vaus 2002b ).”
BackgroundDescriptive Social Norms as Underappreciated Sources of Social Control
Cialdini, R. B. (2007) · Psychometrika · doi:10.1007/s11336-006-1560-6 · Cited by 606 · cited 3×
“…marketing authors have a wealth of other advice relevant to any such programme (for instance, Cialdini, 2003, 2007a, 2007b, 2007c; Goldstein and Cialdini, 2007; McKenzieMohr, 1994, 2000; McKenzie-Mohr and Smith, 1999; National Research Council, Committee on the Human Dimensions of Global…”
BackgroundShove, E., Watson, M., Hand, M., & Ingram, J. (2007) · doi:10.5040/9781474293679 · Cited by 603
Promoting household energy conservation
Steg, L. (2008) · Energy Policy · doi:10.1016/j.enpol.2008.09.027 · Cited by 592 · cited 2×
“…relevant to any such programme (for instance, Cialdini, 2003, 2007a, 2007b, 2007c; Goldstein and Cialdini, 2007; McKenzieMohr, 1994, 2000; McKenzie-Mohr and Smith, 1999; National Research Council, Committee on the Human Dimensions of Global Change, 2002; Shipworth, 2000; Steg, 2008; Stern, 1992).”
BackgroundWhat psychology knows about energy conservation.
Stern, P. C. (1992) · American Psychologist · doi:10.1037//0003-066x.47.10.1224 · Cited by 493
Cited by
Thermal comfort and building energy consumption implications—A review
Yang, L., Yan, H., & Lam, J. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.062 · Cited by 1,448
Zero energy buildings and sustainable development implications – A review
Li, D. H. W., Yang, L., & Lam, J. C. (2013) · Energy · doi:10.1016/j.energy.2013.01.070 · Cited by 564
Smart metering: what potential for householder engagement?
Darby, S. (2010) · Building Research & Information · doi:10.1080/09613218.2010.492660 · Cited by 458
Althaher, S., Mancarella, P., & Mutale, J. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2014.2388357 · Cited by 426
Li, D. H. W., Yang, L., & Lam, J. C. (2012) · Energy · doi:10.1016/j.energy.2012.03.044 · Cited by 382
How people use thermostats in homes: A review
Peffer, T., Pritoni, M., Meier, A., Aragon, C., & Perry, D. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.06.002 · Cited by 342
Building evaluation: practice and principles
Leaman, A., Stevenson, F., & Bordass, B. (2010) · Building Research & Information · doi:10.1080/09613218.2010.495217 · Cited by 270
Targeting household energy-efficiency measures using sensitivity analysis
Firth, S. K., Lomas, K. J., & Wright, A. J. (2010) · Building Research & Information · doi:10.1080/09613210903236706 · Cited by 224
“These studies include a nationally representative survey of around 500 English dwellings, which is collecting information on heating practices and monitoring energy use and internal temperatures (Shipworth et al., 2009); a study monitoring appliance energy-use trends in domestic buildings (Firth et al.”
BackgroundSelf-citationGram-Hanssen, K. (2013) · Energy Efficiency · doi:10.1007/s12053-012-9184-4 · Cited by 174
Smart technology in the home: time for more clarity
Darby, S. J. (2018) · Building Research & Information · doi:10.1080/09613218.2017.1301707 · Cited by 174
“Studies of how programmable thermostats affect consumption (e.g. Sanquist, Schneider, & Meier, 2010; Shipworth et al. 2010), and”
BackgroundThe shape of warmth: temperature profiles in living rooms
Huebner, G. M., McMichael, M., Shipworth, D., Shipworth, M., Durand-Daubin, M., & Summerfield, A. J. (2015) · Building Research & Information · doi:10.1080/09613218.2014.922339 · Cited by 56
“The data analysed in this paper are taken from the Carbon Reduction in Buildings Home Energy Survey (CaRB HES), the first national survey exclusively focused on energy use in English homes1 that commenced in early 2007 (for details, see Shipworth et al., 2010).”
BackgroundMethodSelf-citation
Metadata
- Authors
- Shipworth, M., Firth, S. K., Gentry, M. I., Wright, A. J., Shipworth, D. T., & Lomas, K. J.
- Venue
- Building Research & Information
- Publisher
- Informa UK Limited
- Published
- 2009-11-17
- Volume
- 38
- Issue
- 1
- Pages
- 50-69
- ISSN
- 0961-3218 (ISSN-L)
- 1466-4321
- OpenAlex
- W2029816538
- Cited by
- 220
- References
- 26
- FWCI
- 29.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.