CoChat

Air temperature thresholds for indoor comfort and perceived air quality

Open access
Zhang, Hui, Arens, Edward, Pasut, Wilmer · 2011 · Building Research & Information
Cited by 137

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Air temperature thresholds are investigated and proposed for acceptable comfort in air-conditioned buildings. Using the ASHRAE database of field studies in which acceptability votes were obtained from occupants, it is shown that within the thresholds the acceptability is indistinguishable. Therefore, there is little gain from conditioning spaces to an ‘optimum’ air temperature, a practice that involves significant energy cost. However, beyond the thresholds there is a significant drop-off in acceptability. Ideally, air-conditioning would be used only when the environmental conditions are beyond the thresholds. The use of ceiling fans or personal environmental control systems broadens the threshold range. Thresholds are determined for both air-conditioned and ventilation-cooled buildings in the database. The equally acceptable range between the thresholds is 8–10 K in both types of buildings. It is possible that a perception of reduced air quality in warm environments could impose an upper temperature threshold. Perceived air quality is examined in two laboratory studies with air temperatures ranging from 18 to 30°C. Perceived air quality is seen to be closely correlated to thermal comfort rather than to temperature; as long as thermal comfort is maintained by air movement, perceived air quality will be acceptable. Relationships between temperature thresholds and productivity, operating set-points, and energy use are also discussed. Les seuils de température de l'air sont étudiés et proposés pour un confort acceptable dans les immeubles climatisés. En utilisant les études de terrain figurant dans la base de données de la Société américaine des Ingénieurs en Chauffage, Réfrigération et Climatisation (ASHRAE), dans lesquelles il a été obtenu de la part des occupants des réponses relatives à l'acceptabilité, il est montré que, dans la limite des seuils, l'acceptabilité n'est pas discernable. Il y a par conséquent peu de bénéfice à climatiser des espaces à une température « optimale » de l'air ce qui êntraine des frais significatifs. Cependant, au-delà des seuils, l'on constate une baisse sensible de l'acceptabilité. Dans l'idéal, la climatisation ne serait utilisée que lorsque les conditions environnementales dépassent les seuils. L'utilisation de ventilateurs de plafond ou de systèmes de contrôle individuel de l'environnement élargit la plage des seuils. Les seuils sont définis à la fois pour les immeubles climatisés et les immeubles refroidis par ventilation figurant dans la base de données. La plage offrant une égale acceptabilité entre les seuils se situe à 8-10 K dans les deux types d'immeubles. Il est possible que la perception d'une réduction de la qualité de l'air dans des environnements chauds puisse imposer un seuil de température supérieur. La qualité de l'air perçue est examinée dans deux études de laboratoire pour des températures de l'air allant de 18 °C à 30 °C. Il apparaît que la qualité de l'air perçue est étroitement corrélée au confort thermique plutôt qu'à la température; tant que le confort thermique est maintenu par la circulation d'air, la qualité de l'air perçue sera acceptable. Il est également discuté des relations entre les seuils de température et la productivité, les points de consigne et l'utilisation de l'énergie. Mots clés: confort adaptatif circulation d'air immeubles climatisés fonctionnement libre contrôle individuel de l'environnement (CIE) acceptabilité thermique confort thermique

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/09613218.2011.552703

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 137

Metadata

Authors
Zhang, H., Arens, E., & Pasut, W.
Venue
Building Research & Information
Published
2011-03-22
Volume
39
Issue
2
Pages
134-144
ISSN
  • 0961-3218 (ISSN-L)
  • 1466-4321
OpenAlex
W2114187632
Cited by
137
References
1
FWCI
14.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.