Evolving opportunities for providing thermal comfort
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
The building industry needs a fundamental paradigm shift in its notion of comfort, to find low-energy ways of creating more thermally dynamic and non-uniform environments that bring inhabitants pleasure. Strategies for providing enriched thermal environments must be conjoined with reducing energy; these are inseparable for any building striving for high performance. The objective of current comfort standards is to have no more than 20% of occupants dissatisfied, yet buildings are not reaching even that scant goal. A significant energy cost is incurred by the current practice of controlling buildings within a narrow range of temperatures (often over-cooling in the summer). If building designers and operators can find efficient ways to allow building temperatures to float over a wider range, while affording occupants individual control of comfort, the potential for energy savings is enormous. Five new ways of thinking, or paradigm shifts, are presented for designing or operating buildings to provide enhanced thermal experiences. They are supported by examples of research conducted by the Center for the Built Environment, and include shifts from centralized to personal control, from still to breezy air movement, from thermal neutrality to delight, from active to passive design, and from system disengagement to improved feedback loops.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal Environmental Conditions for Human Occupancy
Ashrae, S. (1992) · Medical Entomology and Zoology · Cited by 6,092
(1998) · eScholarship (California Digital Library) · Cited by 1,934
Cabanac, M. (1971) · Science · doi:10.1126/science.173.4002.1103 · Cited by 1,521
Hoyt, T., Arens, E., & Zhang, H. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.09.010 · Cited by 607
Self-citationHuman thermal sensation and comfort in transient and non-uniform thermal environments
Zhang, H. (2003) · eScholarship (California Digital Library) · Cited by 594
Self-citationZhang, H., Arens, E., Huizenga, C., & Han, T. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.06.018 · Cited by 539
Self-citationThe adaptive model of thermal comfort and energy conservation in the built environment
de Dear, R., & Schiller Brager, G. (2001) · International Journal of Biometeorology · doi:10.1007/s004840100093 · Cited by 516
Zhang, H., Arens, E., Huizenga, C., & Han, T. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.06.015 · Cited by 476
Self-citationHuizenga, C., Abbaszadeh, S., Zagreus, L., & Arens, E. A. (2006) · eScholarship (California Digital Library) · Cited by 429
Self-citation(ACEEE summer study on energy efficiency in buildings)
Available, N. (1990) · University of North Texas Digital Library (University of North Texas) · Cited by 363
Creating the Productive Workplace: Places to Work Creatively
(2006) · Taylor & Francis eBooks · doi:10.4324/9780203696880 · Cited by 358
Revisiting an old hypothesis of human thermal perception: alliesthesia
de Dear, R. (2011) · Building Research & Information · doi:10.1080/09613218.2011.552269 · Cited by 333
Comfort, perceived air quality, and work performance in a low-power task–ambient conditioning system
Zhang, H., Arens, E., Kim, D., Buchberger, E., Bauman, F., & Huizenga, C. (2010) · Building and Environment · doi:10.1016/j.buildenv.2009.02.016 · Cited by 324
Self-citationGlobal database of thermal comfort field experiments
de Dear, R. (1998) · ASHRAE winter conference papers · Cited by 320
Some Quantitative Relations between Indoor Environmental Quality and Work Performance or \nHealth
Seppänen, O., & Fisk, W. J. (2006) · eScholarship (California Digital Library) · Cited by 314
Seppänen, O., & Fisk, W. J. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01111.x · Cited by 277
Thermal pleasure in built environments: physiology of alliesthesia
Parkinson, T., & de Dear, R. (2015) · Building Research & Information · doi:10.1080/09613218.2015.989662 · Cited by 263
Proceedings of Healthy Buildings
Brohus, H. (2006) · Cited by 249
Mendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
sMAP: a simple measurement and actuation profile for physical information
Dawson-Haggerty, S., Jiang, X., Tolle, G., Ortiz, J., & Culler, D. (2010) · Proceedings of the 8th ACM Conference on Embedded Networked Sensor Systems · doi:10.1145/1869983.1870003 · Cited by 228
Occupant satisfaction in mixed-mode buildings
Brager, G. S., & Baker, L. (2009) · Building Research & Information · doi:10.1080/09613210902899785 · Cited by 228
Self-citationPerceived intensity of peripheral thermal stimuli is independent of internal body temperature.
Mower, G. D. (1976) · Journal of Comparative and Physiological Psychology · doi:10.1037/h0077284 · Cited by 179
Air temperature thresholds for indoor comfort and perceived air quality
Zhang, H., Arens, E., & Pasut, W. (2011) · Building Research & Information · doi:10.1080/09613218.2011.552703 · Cited by 137
Self-citationAir movement preferences observed in office buildings
Zhang, H., Arens, E. A., Fard, S. A., Huizenga, C., Paliaga, G., Brager, G. S., & Zagreus, L. (2007) · International Journal of Biometeorology · doi:10.1007/s00484-006-0079-y · Cited by 136
Self-citationToftum, J. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00271.x · Cited by 136
Control of temperature for health and productivity in offices
Seppänen, O., Fisk, W. J., & Faulkner, D. M. (2004) · eScholarship (California Digital Library) · Cited by 129
Melikov, A. K., Skwarczyński, M., Kaczmarczyk, J., & Zabecky, J. (2012) · Indoor Air · doi:10.1111/ina.12012 · Cited by 124
Energy savings from extended air temperature setpoints and reductions in room air mixing
Hoyt, T., Lee, K. H., Zhang, H., et al. (2005) · eScholarship (California Digital Library) · Cited by 122
Self-citationArens, E. A., Turner, S., Zhang, H., & Paliaga, G. (2009) · eScholarship (California Digital Library) · Cited by 115
Self-citationIndoor thermal factors and symptoms in office workers: findings from the US EPA BASE study
Mendell, M. J., & Mirer, A. G. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00592.x · Cited by 115
Indoor Climate and Productivity in Offices
Schiavon, S., & Zecchin, R. (2008) · eScholarship (California Digital Library) · Cited by 58
Perception of Transient Thermal Environments: Pleasure and Alliesthesia
Cândido, C., de Dear, R., & Parkinson, T. (2012) · Cited by 49
Two Degrees: The Built Environment and Our Changing Climate
McGregor, A., Roberts, C., & Cousins, F. (2013) · Routledge eBooks · doi:10.4324/9780203082997 · Cited by 37
Enhancing productivity while reducing energy use in buildings
Wyon, D. P. (2000) · Cited by 28
Power to the people: personal control in offices for thermal comfort and energy savings
Taub, M. (2013) · eScholarship (California Digital Library) · Cited by 17
Energy-efficient comfort with a heated/cooled chair
Pasut, W., Zhang, H., Arens, E., & Zhai, Y. (2014) · Cited by 6
Self-citation
Cited by
Ten questions concerning well-being in the built environment
Altomonte, S., Allen, J., Bluyssen, P. M., Brager, G., Heschong, L., Loder, A., Schiavon, S., Veitch, J. A., Wang, L., & Wargocki, P. (2020) · Building and Environment · doi:10.1016/j.buildenv.2020.106949 · Cited by 303
Self-citationWhat is wrong with energy efficiency?
Shove, E. (2018) · Building Research & Information · doi:10.1080/09613218.2017.1361746 · Cited by 300
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Papadopoulos, S., Kontokosta, C. E., Vlachokostas, A., & Azar, E. (2019) · Building and Environment · doi:10.1016/j.buildenv.2019.03.062 · Cited by 164
Healthy excursions outside the thermal comfort zone
van Marken Lichtenbelt, W., Hanssen, M., Pallubinsky, H., Kingma, B., & Schellen, L. (2017) · Building Research & Information · doi:10.1080/09613218.2017.1307647 · Cited by 109
Metadata
- Authors
- Brager, G., Zhang, H., & Arens, E.
- Venue
- Building Research & Information
- Publisher
- Informa UK Limited
- Published
- 2015-01-28
- Volume
- 43
- Issue
- 3
- Pages
- 274-287
- ISSN
- 0961-3218 (ISSN-L)
- 1466-4321
- OpenAlex
- W2033726393
- Cited by
- 164
- References
- 36
- FWCI
- 22.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.