The DOI matches its Crossref record; 86 of the 86 references it cites were found in a registry or an index.
A history of blood glucose meters and their role in self-monitoring of diabetes mellitus
Abstract
Self-monitoring blood glucose (SMBG) systems have the potential to play an important role in the management of diabetes and in the reduction of risk of serious secondary clinical complications. This review describes the transition from simple urine sugar screening tests to sophisticated meter and reagent strip systems to monitor blood glucose. Significant developments in design and technology over the past four decades are described since the first meter was introduced in 1970. Factors that have influenced this evolution and the challenges to improve analytical performance are discussed. Current issues in the role of SMBG from the clinical, patient and manufacturer perspectives, notably adherence, costs and regulations, are also considered.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Urine is a noninvasive fluid for inexpensive, easy to use glucose testing, that has historically dominated diabetes monitoring before the blood glucose sensors era (Figure 4F) 169.”
From Glucose biosensors in clinical practice: principles, limits and perspectives of currently used devices (2022) · cites this paper as [169]
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Standards of medical care in diabetes 2010
American Diabetes Association (2010) · Diabetes Care · doi:10.2337/dc10-s011 · Cited by 3,470
Laboratory techniques in biochemistry and molecular biology
Work, T. S., & Work, E. (1973) · Food and Cosmetics Toxicology · doi:10.1016/0015-6264(73)90270-8 · Cited by 2,181
Evaluating clinical accuracy of systems for self-monitoring of blood glucose
Clarke, W. L., Cox, D., Gonder-Frederick, L. A., Carter, W., & Pohl, S. L. (1987) · Diabetes Care · doi:10.2337/diacare.10.5.622 · Cited by 1,435
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Folin, O., & Wu, H. M. (1919) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)87378-1 · Cited by 1,191
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. A. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,132
American Diabetes Association (2003) · Diabetes Care · doi:10.2337/diacare.26.2007.s106 · Cited by 1,037
Research works printed but not linked: 14
- IBMS History Committee, 2005, From matula to mass spectrometry: a history of urine tests in the investigation of human disease.
- Benedict SR., 1908, J Biol Chem, 277, e5
- Walter B., 1983, Anal Chem, 55, 498A
- Sonntag O., 1993, Analysis with carrier-bound reagents, 1
- Hill JB, 1961, J Lab Clin Med, 57, 970
- Cheah JS, 1974, Singapore Med J, 15, 51
- Thai AC, 1981, Singapore Med J, 22, 275
- 1982, Clin Chem, 28, 2448
- Forest RD, 1987, Diabetes Res, 6, 119
- American Diabetes Association, 1996, Diabetes Care, 19, 62
- Devreese K, 1993, Eur J Clin Chem Clin Biochem, 31, 829
- International Organisation for Standardisation, 2003, In vitro diagnostic test systems for blood glucose monitoring systems for self testing in managing diabetes mellitus.
- American Diabetes Association, 2010, Diabetes Care, 33, Sll
- National Institute for Health and Clinical Excellence, 2009, Type 2 diabetes: neiver agents for blood glucose control in type 2 diabetes (Partial update of CG66)
Cited by
Sorted by citations
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Enzymes: principles and biotechnological applications
Robinson, P. (2015) · Essays in Biochemistry · doi:10.1042/bse0590001 · Cited by 1,295
Metabolomics: an emerging but powerful tool for precision medicinePreprint
Clish, C. B. (2015) · Molecular Case Studies · doi:10.1101/mcs.a000588 · Cited by 769
Cappon, G., Vettoretti, M., Sparacino, G., & Facchinetti, A. (2019) · Diabetes & Metabolism Journal · doi:10.4093/dmj.2019.0121 · Cited by 477
Wearable Electrochemical Glucose Sensors in Diabetes Management: A Comprehensive Review
Saha, T., Del Caño, R., Mahato, K., De la Paz, E., Chen, C., Ding, S., Yin, L., & Wang, J. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00078 · Cited by 442
Metadata
- Authors
- Clarke, S. F., & Foster, J. R.
- Affiliations
- Institute of Biomedical Science (GB)
- Venue
- British Journal of Biomedical Science
- Publisher
- Frontiers Media SA
- Published
- 2012-01
- Volume
- 69
- Issue
- 2
- Pages
- 83-93
- ISSN
- 0967-4845 (ISSN-L)
- OpenAlex
- W103326292
- Cited by
- 456
- References
- 86
- Citations by year
- 2026: 12 · 2025: 23 · 2024: 38 · 2023: 57 · 2022: 44 · 2021: 43 · 2020: 47 · 2019: 35 · 2018: 26 · 2017: 28 · 2016: 41 · 2015: 30 · 2014: 24 · 2013: 6
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- British Journal of Biomedical Science (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Keywords
- blood glucose meters, self-monitoring of blood glucose, diabetes mellitus, test strips, analytical performance, patient adherence, cost, regulation, diabetes management
- MeSH terms
- Diabetes Mellitus, Equipment Design, Humans, Hyperglycemia, Hypoglycemic Agents, Insulin, Blood Glucose Self-Monitoring, Reproducibility of Results, History, 19th Century, History, 20th Century, History, 21st Century
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review