Shape optimization in steady blood flow: A numerical study of non-Newtonian effects
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
This paper presents a numerical study of non-Newtonian effects on the solution of shape optimization problems involving unsteady pulsatile blood flow. We consider an idealized two dimensional arterial graft geometry. Our computations are based on the Navier-Stokes equations generalized to non-Newtonian fluid, with the modified Cross model employed to account for the shear-thinning behavior of blood. Using a gradient-based optimization algorithm, we compare the optimal shapes obtained using both the Newtonian and generalized Newtonian constitutive equations. Depending on the shear rate prevalent in the domain, substantial differences in the flow as well as in the computed optimal shape are observed when the Newtonian constitutive equation is replaced by the modified Cross model. By varying a geometric parameter in our test case, we investigate the influence of the shear rate on the solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2021) · A First Course in Statistical Programming with R · doi:10.1017/9781108993456.011 · Cited by 13,724
(1999) · Springer Series in Operations Research and Financial Engineering · doi:10.1007/b98874 · Cited by 9,482
Numerical Methods for Unconstrained Optimization and Nonlinear Equations
Dennis, J. E., & Schnabel, R. B. (1996) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971200 · Cited by 7,615
Iterative methods for linear and nonlinear equations
(1996) · Choice Reviews Online · doi:10.5860/choice.33-4556 · Cited by 1,947
Iterative Methods for Linear and Nonlinear Equations
Kelley, C. T. (1995) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611970944 · Cited by 1,635 · cited 1×
“We compute an approximation of this solution using an Newton GMRES method (Kelley 1995).”
MethodKu, D. N. (1997) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.29.1.399 · Cited by 1,477 · cited 1×
“The Womersley number defines the ratio of inertial forces to viscous forces; a study on Womersley number effects in blood flow in arteries can be found in Ku ( 1997 ); Ryval et al.”
BackgroundHughes, T. J. R., Franca, L. P., & Hulbert, G. M. (1989) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(89)90111-4 · Cited by 1,458 · cited 1×
“…Xnel e¼1 ð VeðaÞ tMOM 1 r ½rðuh·7whÞ27·sðwh;qhÞ · ½rðuh·7uhÞ27·sðuh;phÞ dxh þ ð VðaÞ qh7·uh dxh ¼ ð GhðaÞ wh·hh dxh ð8Þ for all uh [Vh and for all qh [ H 1hðVðaÞÞ: The GLS stabilization (Shakib 1988, Hughes et al. 1989, Tezduyar et al. 1992) provides stability at high element-level…”
A new finite element formulation for computational fluid dynamics: II. Beyond SUPG
Hughes, T. J. R., Mallet, M., & Akira, M. (1986) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(86)90110-6 · Cited by 1,106
Dennis, J. E., & Schnabel, R. B. (1996) · Cited by 949
Tezduyar, T. E., Behr, M., & Liou, J. (1992) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(92)90059-s · Cited by 838 · cited 1×
“…VeðaÞ tMOM 1 r ½rðuh·7whÞ27·sðwh;qhÞ · ½rðuh·7uhÞ27·sðuh;phÞ dxh þ ð VðaÞ qh7·uh dxh ¼ ð GhðaÞ wh·hh dxh ð8Þ for all uh [Vh and for all qh [ H 1hðVðaÞÞ: The GLS stabilization (Shakib 1988, Hughes et al. 1989, Tezduyar et al. 1992) provides stability at high element-level Reynolds numbers and…”
Self-citationNon-Newtonian blood flow in human right coronary arteries: steady state simulations
Johnston, B. M., Johnston, P. R., Corney, S., & Kilpatrick, D. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.09.016 · Cited by 689 · cited 4×
“The papers of Yeleswarapu (1996), Gijsen et al. (1999), Leuprecht and Perktold (2001), Neofytou and Drikakis (2003) and Johnston et al. (2004) provide a small sample of the research on non-Newtonian effects on blood flow.”
BackgroundMethodInfluentialTezduyar, T. E., Behr, M., Mittal, S., & Liou, J. (1992) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(92)90060-w · Cited by 684 · cited 1×
“…VeðaÞ tMOM 1 r ½rðuh·7whÞ27·sðwh;qhÞ · ½rðuh·7uhÞ27·sðuh;phÞ dxh þ ð VðaÞ qh7·uh dxh ¼ ð GhðaÞ wh·hh dxh ð8Þ for all uh [Vh and for all qh [ H 1hðVðaÞÞ: The GLS stabilization (Shakib 1988, Hughes et al. 1989, Tezduyar et al. 1992) provides stability at high element-level Reynolds numbers and…”
Self-citationGijsen, F. J. H., van de Vosse, F. N., & Janssen, J. D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00015-9 · Cited by 580 · cited 6×
“We note that the modified Cross model is equivalent to the Carreau-Yasuda model (Yeleswarapu 1996, Gijsen et al. 1999, Leuprecht and Perktold 2001) provided that the parameters in both models are properly related.”
BackgroundMethodResultInfluentialComputational vascular fluid dynamics: problems, models and methods
Quarteroni, A., Tuveri, M., & Veneziani, A. (2000) · Computing and Visualization in Science · doi:10.1007/s007910050039 · Cited by 480 · cited 1×
“Part of the challenge in this field is the accurate treatment of the haemodynamic behaviour—see, e.g. Quarteroni et al. (2000) for a recent review in this field.”
BackgroundScott, R., & Gunzburger, M. D. (1991) · Mathematics of Computation · doi:10.2307/2938726 · Cited by 362 · cited 1×
“We define the function spaces S ¼ {uju [ ½H 1ðVÞ nsd ; u ¼ g on Gg}; V ¼ {uju [ ½H 1ðVÞ nsd ; u ¼ 0 on Gg}; where H 1(V) is defined in the usual way (Girault and Raviart 1986, Gunzburger 1989).”
Perktold, K., Peter, R. O., Resch, M., & Langs, G. (1991) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(91)90100-l · Cited by 211 · cited 1×
“Gijsen et al. (1999) show higher differences in the axial velocity profile compared to results obtained by Perktold et al. (1991) for a 3D carotid bifurcation study when using Computer Methods in Biomechanics and Biomedical Engineering ISSN 1025-5842 print/ISSN 1476-8259 online q 2005 Taylor &…”
ResultComputational Fluid Dynamics as a Development Tool for Rotary Blood Pumps
Burgreen, G. W., Antaki, J. F., Wu, Z. J., & Holmes, A. J. (2001) · Artificial Organs · doi:10.1046/j.1525-1594.2001.025005336.x · Cited by 148 · cited 2×
“Shape optimization procedures have been extensively studied in the context of aerodynamic flows [7, 8], and there has been recent interest to extend these successes, to biomedical applications [9–12].”
BackgroundA better consistency for low-order stabilized finite element methods
Jansen, K. E., Collis, S. S., Whiting, C. H., & Shaki, F. (1999) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)00284-9 · Cited by 138 · cited 1×
“A variational reconstruction of second derivatives (Jansen et al. 1999) could be used to improve the consistency of our approximation.”
MethodComputational Flow Optimization of Rotary Blood Pump Components
Antaki, J. F., Ghattas, O. N., Burgreen, G. W., et al. (1995) · Artificial Organs · doi:10.1111/j.1525-1594.1995.tb02389.x · Cited by 62 · cited 2×
“Shape optimization procedures have been extensively studied in the context of aerodynamic flows [7, 8], and there has been recent interest to extend these successes, to biomedical applications [9–12].”
BackgroundAbraham, F., Behr, M., & Heinkenschloss, M. (2004) · Finite Elements in Analysis and Design · doi:10.1016/j.finel.2004.06.001 · Cited by 48 · cited 4×
“It depends on the element length he, which in our computations is specified by the adv definition in [24].”
BackgroundInfluentialSelf-citationGuo, L.-R. R., Steinman, D. A., Moon, B. C., et al. (2001) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(01)02801-6 · Cited by 18 · cited 2×
“Guo et al. (2001) study the effect of graft placement vis-a-vis the occlusion as an important criterion for improving the outcome of coronary artery bypass grafting.”
Background
Metadata
- Authors
- Abraham, F., Behr, M., & Heinkenschloss, M.
- Venue
- Computer Methods in Biomechanics and Biomedical Engineering
- Publisher
- Informa UK Limited
- Published
- 2005-04
- Volume
- 8
- Issue
- 2
- Pages
- 127-137
- ISSN
- 1025-5842 (ISSN-L)
- 1476-8259
- OpenAlex
- W2153732303
- Cited by
- 182
- References
- 21
- FWCI
- 6.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.