CoChat

Dynamic accuracy of inertial measurement units during simple pendulum motion: Technical Note

Brodie, M.A., Walmsley, A., Page, W. · 2008 · Computer Methods in Biomechanics and Biomedical Engineering
Cited by 77

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

A motion measurement system based on inertial measurement units (IMUs) has been suggested as an alternative to contemporary video motion capture. This paper reports an investigation into the accuracy of IMUs in estimating 3D orientation during simple pendulum motion. The IMU vendor's (XSens Technologies) accuracy claim of 3 degrees root mean squared (RMS) error is tested. IMUs are integrated electronic devices that contain accelerometers, magnetometers and gyroscopes. The motion of a pendulum swing was measured using both IMUs and video motion capture as a reference. The IMU raw data were processed by the Kalman filter algorithm supplied by the vendor and a custom fusion algorithm developed by the authors. The IMU measurement of pendulum motion using the vendor's Kalman filter algorithm did not compare well with the video motion capture with a RMS error of between 8.5 degrees and 11.7 degrees depending on the length and type of pendulum swing. The maximum orientation error was greater than 30 degrees , occurring approximately eight seconds into the motion. The custom fusion algorithm estimation of orientation compared well with the video motion capture with a RMS error of between 0.8 degrees and 1.3 degrees . Future research should concentrate on developing a general purpose fusion algorithm and vendors of IMUs should provide details about the errors to be expected in different measurement situations, not just those in a 'best case' scenario.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10255840802125526

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 77

Metadata

Authors
Brodie, M. A., Walmsley, A., & Page, W.
Venue
Computer Methods in Biomechanics and Biomedical Engineering
Published
2008-06
Volume
11
Issue
3
Pages
235-242
ISSN
  • 1025-5842 (ISSN-L)
  • 1476-8259
OpenAlex
W1531332991
Cited by
77
References
1
FWCI
8.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Dynamic accuracy of inertial measurement units during simple pendulum motion: Technical Note. https://app.cochat.ai/papers/10.1080/10255840802125526
The paper
Brodie, M. A., Walmsley, A., & Page, W. (2008). Dynamic accuracy of inertial measurement units during simple pendulum motion: Technical Note. Computer Methods in Biomechanics and Biomedical Engineering. https://doi.org/10.1080/10255840802125526

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.