Validation of inertial measurement units with an optoelectronic system for whole-body motion analysis
Open accessAbstract
The potential of inertial measurement units (IMUs) for ergonomics applications appears promising. However, previous IMUs validation studies have been incomplete regarding aspects of joints analysed, complexity of movements and duration of trials. The objective was to determine the technological error and biomechanical model differences between IMUs and an optoelectronic system and evaluate the effect of task complexity and duration. Whole-body kinematics from 12 participants was recorded simultaneously with a full-body Xsens system where an Optotrak cluster was fixed on every IMU. Short functional movements and long manual material handling tasks were performed and joint angles were compared between the two systems. The differences attributed to the biomechanical model showed significantly greater (P ≤ .001) RMSE than the technological error. RMSE was systematically higher (P ≤ .001) for the long complex task with a mean on all joints of 2.8° compared to 1.2° during short functional movements. Definition of local coordinate systems based on anatomical landmarks or single posture was the most influent difference between the two systems. Additionally, IMUs accuracy was affected by the complexity and duration of the tasks. Nevertheless, technological error remained under 5° RMSE during handling tasks, which shows potential to track workers during their daily labour.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Neck RMSE results varied between less than 1° and 9°, showing good joint measurement validity.
“RMSE results varied between less than 1° and 9°, showing good joint measurement validity [33,34,37,40,41].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Hip RMSE and correlation coefficients varied from 0.2 to 9.3° and 0.53 to 1.00, showing fair to excellent validity.
“RMSE and correlation coefficients varied respectively from 0.2 to 9.3° and 0.53 to 1.00, showing fair to excellent validity [5,30,37,41,42,46,53,54,55,56,57,58,59].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Trunk validity was similar across all movement planes and axes.
“Validity was similar across all movement planes and axes [34,36,37,38,41,46,47,48,49,50,51].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Ankle RMSE and correlation coefficients varied from 0.4 to 18.8° and 0.33 to 0.99.
“RMSE and correlation coefficients varied respectively from 0.4 to 18.8° and 0.33 to 0.99 [29,37,41,43,53,54,55,57,59,62,63].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Knee RMSE and correlation varied from 1 to 11.5° and 0.4 to 1.00.
“RMSE and coefficient correlation varied respectively from 1 to 11.5° and 0.4 to 1.00 [5,30,37,41,43,48,50,53,54,55,57,58,59,60,61].”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
The choice of the biomechanical model used to convert M/IMU orientation data into anatomically meaningful information influences validity differently depending on the joint studied.
“Also, as demonstrated by Robert-Lachaine et al. [37], the choice of the biomechanical model used to convert M/IMU orientation data into anatomically meaningful information will also influence validity differently depending on the joint studied.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Shoulder rotation is more influenced by the biomechanical model than shoulder flexion-extension or abduction/adduction.
“According to Robert-Lachaine et al., shoulder rotation is also more influenced by the biomechanical model than shoulder flexion–extension or abduction/adduction.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Biomechanical models used for the upper limbs are more likely to add variability, leading to larger RMSE.
“Their results showed that biomechanical models used for the upper limbs are more likely to add variability, leading to larger RMSE.”
From Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review (2019) · cites this paper as [37]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917 · see citing works
Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M., Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R., McQuade, K. J., Wang, X., et al. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.05.042 · Cited by 4,569 · see citing works
Wu, G., Siegler, S., Allard, P., Kirtley, C., Leardini, A., Rosenbaum, D., Whittle, M., DʼLima, D. D., Cristofolini, L., Witte, H., et al. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00222-6 · Cited by 3,249 · see citing works
Human movement analysis using stereophotogrammetry
Leardini, A., Chiari, L., Croce, U. D., & Cappozzo, A. (2005) · Gait & Posture · doi:10.1016/j.gaitpost.2004.05.002 · Cited by 1,239 · see citing works
(2009) · Cited by 701 · see citing works
(1998) · Choice Reviews Online · doi:10.5860/choice.35-6297 · Cited by 430 · see citing works
New least squares solutions for estimating the average centre of rotation and the axis of rotation
Gamage, S. S. H. U., & Lasenby, J. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00160-9 · Cited by 378 · see citing works
The use of inertial sensors system for human motion analysis
Cuesta-Vargas, A. I., Galán-Mercant, A., & Williams, J. M. (2010) · Physical Therapy Reviews · doi:10.1179/1743288x11y.0000000006 · Cited by 369 · see citing works
Harrington, M., Zavatsky, A. B., LAWSON, S. E. M., Yuan, Z., & Theologis, T. N. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.02.003 · Cited by 367 · see citing works
Ambulatory measurement of arm orientation
Luinge, H. J., Veltink, P. H., & Baten, C. T. M. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.11.011 · Cited by 356 · see citing works
Knutzen, K. M. (1998) · American Journal of Human Biology · doi:10.1002/(sici)1520-6300(1998)10:6 · Cited by 339 · see citing works
Innovative system for real-time ergonomic feedback in industrial manufacturing
Vignais, N., Miezal, M., Bleser, G., Mura, K., Gorecky, D., & Marin, F. (2012) · Applied Ergonomics · doi:10.1016/j.apergo.2012.11.008 · Cited by 335 · see citing works
Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics
Zhang, J.-T., Novak, A. C., Brouwer, B., & Li, Q. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/8/n63 · Cited by 314 · see citing works
Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311 · see citing works
Magnetic distortion in motion labs, implications for validating inertial magnetic sensors
Vries, W. H. K. D., Veeger, H. E. J., Baten, C. T. M., & van der Helm, F. C. T. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2008.12.004 · Cited by 292 · see citing works
Shoulder and Elbow Joint Angle Tracking With Inertial Sensors
El‐Gohary, M., & McNames, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208750 · Cited by 264 · see citing works
Joint kinematics estimate using wearable inertial and magnetic sensing modules
Picerno, P., Cereatti, A., & Cappozzo, A. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.04.003 · Cited by 263 · see citing works
‘Outwalk’: a protocol for clinical gait analysis based on inertial and magnetic sensors
Cutti, A. G., Ferrari, A., Garofalo, P., Raggi, M., Cappello, A., & Ferrari, A. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0545-x · Cited by 218 · see citing works
Palermo, E., Rossi, S., Marini, F., Patanè, F., & Cappa, P. (2014) · Measurement · doi:10.1016/j.measurement.2014.03.004 · Cited by 183 · see citing works
Ferrari, A., Cutti, A. G., Garofalo, P., Raggi, M., Heijboer, M., Cappello, A., & Davalli, A. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0544-y · Cited by 181 · see citing works
Methods for Measuring and Representing Automobile Occupant Posture
Reed, M. P., Manary, M. A., & Schneider, L. W. (1999) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/1999-01-0959 · Cited by 178 · see citing works
Kim, S., & Nussbaum, M. A. (2012) · Ergonomics · doi:10.1080/00140139.2012.742932 · Cited by 151 · see citing works
Estimation of the hip joint centre in human motion analysis: A systematic review
Kainz, H., Carty, C. P., Modenese, L., Boyd, R. N., & Lloyd, D. G. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.02.005 · Cited by 135 · see citing works
Bouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133 · see citing works
Biomechanics of the Wrist Joint
(1991) · Springer eBooks · doi:10.1007/978-1-4612-3208-7 · Cited by 129 · see citing works
Accuracy of inertial motion sensors in static, quasistatic, and complex dynamic motion
Godwin, A., Agnew, M., & Stevenson, J. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000109 · Cited by 107 · see citing works
Inertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106 · see citing works
Evaluation of a hybrid system for three-dimensional measurement of trunk posture in motion
Plamondon, A., Delisle, A., Larue, C., Brouillette, D., McFadden, D., Desjardins, P., & Larivière, C. (2007) · Applied Ergonomics · doi:10.1016/j.apergo.2006.12.006 · Cited by 102 · see citing works
Self-citationSchall, M. C., Fethke, N. B., Chen, H., Oyama, S., & Douphrate, D. I. (2016) · Ergonomics · doi:10.1080/00140139.2015.1079335 · Cited by 96 · see citing works
Dynamic accuracy of inertial measurement units during simple pendulum motion
Brodie, M. A. D., Walmsley, A., & Page, W. (2008) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840802125526 · Cited by 77 · see citing works
Fantozzi, S., Giovanardi, A., Magalhães, F. A., Di Michele, R., Cortesi, M., & Gatta, G. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2015.1088659 · Cited by 74 · see citing works
Gyro Mechanical Performance: The Most Important Parameter
Weinberg, H. (2011) · Cited by 69 · see citing works
Evaluating the properties of the coefficient of multiple correlation (CMC) for kinematic gait data
Røislien, J., Skare, Ø., Opheim, A. I., & Rennie, L. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.05.014 · Cited by 58 · see citing works
Optimization of Inertial Sensor-Based Motion Capturing for Magnetically Distorted Field Applications
Schiefer, C., Ellegast, R. P., Hermanns, I., Kraus, T., Ochsmann, E., Larue, C., & Plamondon, A. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028822 · Cited by 35 · see citing works
Self-citationObjective assessment, repeatability, and agreement of shoulder ROM with a 3D gyroscope
El-Zayat, B. F., Efe, T., Heidrich, A., Anetsmann, R., Timmesfeld, N., Fuchs‐Winkelmann, S., & Schofer, M. D. (2013) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-14-72 · Cited by 22 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Survey of Motion Tracking Methods Based on Inertial Sensors: A Focus on Upper Limb Human Motion
Filippeschi, A., Schmitz, N., Miezal, M., Bleser, G., Ruffaldi, E., & Stricker, D. (2017) · Sensors · doi:10.3390/s17061257 · Cited by 361 · see citing works
Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
Al-Amri, M., Nicholas, K., Button, K., Sparkes, V., Sheeran, L., & Davies, J. (2018) · Sensors · doi:10.3390/s18030719 · Cited by 318 · see citing works
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309 · see citing works
Sensing of joint and spinal bending or stretching via a retractable and wearable badge reel
Li, C., Liu, D., Xu, C., Wang, Z., Shu, S., Sun, Z., Wang, Z. L., & Wang, Z. L. (2021) · Nature Communications · doi:10.1038/s41467-021-23207-8 · Cited by 230 · see citing works
Schall, M. C., Sesek, R. F., & Cavuoto, L. A. (2018) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/0018720817753907 · Cited by 205 · see citing works
Ergonomic postural assessment using a new open-source human pose estimation technology (OpenPose)
Kim, W., Sung, J., Saakes, D. P., Huang, C., & Xiong, S. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103164 · Cited by 192 · see citing works
Sport Biomechanics Applications Using Inertial, Force, and EMG Sensors: A Literature Overview
Taborri, J., Keogh, J., Kos, A., Santuz, A., Umek, A., Urbanczyk, C. A., van der Kruk, E., & Rossi, S. (2020) · Applied Bionics and Biomechanics · doi:10.1155/2020/2041549 · Cited by 175 · see citing works
Borno, M. A., O’Day, J. J., Ibarra, V., Dunne, J. J., Seth, A., Habib, A., Ong, C. F., Hicks, J. L., Uhlrich, S. D., & Delp, S. L. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01001-x · Cited by 155 · see citing works
Prediction of lower limb joint angles and moments during gait using artificial neural networks
Mundt, M., Thomsen, W., Witter, T., Koeppe, A., David, S., Bamer, F., Potthast, W., & Markert, B. A. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02061-3 · Cited by 133 · see citing works
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132 · see citing works
Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters
Teufl, W., Lorenz, M., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s19010038 · Cited by 132 · see citing works
Teufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2019) · PLOS ONE · doi:10.1371/journal.pone.0213064 · Cited by 129 · see citing works
Measurement of Upper Limb Range of Motion Using Wearable Sensors: A Systematic Review
Walmsley, C. P., Williams, S. A., Grisbrook, T., Elliott, C., Imms, C., & Campbell, A. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0167-7 · Cited by 123 · see citing works
Blair, S., Duthie, G., Robertson, S., Hopkins, W., & Ball, K. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.031 · Cited by 117 · see citing works
A narrative review on contemporary and emerging uses of inertial sensing in occupational ergonomics
Lim, S. I., & D’Souza, C. (2020) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2020.102937 · Cited by 112 · see citing works
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.02.029 · Cited by 108 · see citing works
Self-citationTeufl, W., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s18071980 · Cited by 105 · see citing works
Lind, C. M., Abtahi, F., & Forsman, M. (2023) · Sensors · doi:10.3390/s23094259 · Cited by 105 · see citing works
Milosevic, B., Leardini, A., & Farella, E. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00762-7 · Cited by 103 · see citing works
Validation of a 3D Markerless System for Gait Analysis Based on OpenPose and Two RGB Webcams
D’Antonio, E., Taborri, J., Mileti, I., Rossi, S., & Patanè, F. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3081188 · Cited by 103 · see citing works
Determining anatomical frames via inertial motion capture: A survey of methods
Vitali, R. V., & Perkins, N. C. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.109832 · Cited by 100 · see citing works
Validation of an IMU Suit for Military-Based Tasks
Mavor, M. P., Ross, G. B., Clouthier, A. L., Karakolis, T., & Graham, R. B. (2020) · Sensors · doi:10.3390/s20154280 · Cited by 86 · see citing works
Paolo, S. D., Lopomo, N. F., Villa, F. D., Paolini, G., Figari, G., Bragonzoni, L., Grassi, A., & Zaffagnini, S. (2021) · Sensors · doi:10.3390/s21072331 · Cited by 85 · see citing works
Teufl, W., Taetz, B., Miezal, M., Lorenz, M., Pietschmann, J., Jöllenbeck, T., Fröhlich, M., & Bleser, G. (2019) · Sensors · doi:10.3390/s19225006 · Cited by 82 · see citing works
Return to sports after ACL injury 5 years from now: 10 things we must do
Gokeler, A., Grassi, A., Hoogeslag, R. A. G., van Houten, A. H., Lehman, T., Bolling, C. S., Buckthorpe, M. W., Norte, G. E., Benjaminse, A., Heuvelmans, P., et al. (2022) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-022-00514-7 · Cited by 79 · see citing works
Effect of local magnetic field disturbances on inertial measurement units accuracy
Robert‐Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.04.011 · Cited by 77 · see citing works
Self-citationValidity of the Perception Neuron inertial motion capture system for upper body motion analysis
Sers, R., Forrester, S., Moss, E. L., Ward, S., Ma, J., & Zecca, M. (2019) · Measurement · doi:10.1016/j.measurement.2019.107024 · Cited by 75 · see citing works
Conversion of Upper-Limb Inertial Measurement Unit Data to Joint Angles: A Systematic Review
Fang, Z., Woodford, S. C., Senanayake, D., & Ackland, D. C. (2023) · Sensors · doi:10.3390/s23146535 · Cited by 73 · see citing works
Rapp, E., Shin, S., Thomsen, W., Ferber, R., & Halilaj, E. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110229 · Cited by 71 · see citing works
Held, J. P. O., Klaassen, B., Eenhoorn, A., van Beijnum, B.-J. F., Buurke, J. H., Veltink, P. H., & Luft, A. R. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00027 · Cited by 69 · see citing works
Validation of a low-cost inertial motion capture system for whole-body motion analysis
Robert‐Lachaine, X., Mecheri, H., Muller, A., Larue, C., & Plamondon, A. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109520 · Cited by 69 · see citing works
Self-citationLebel, K., Boissy, P., Nguyen, H., & Duval, C. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0347-6 · Cited by 65 · see citing works
Poitras, I., Bielmann, M., Campeau‐Lecours, A., Mercier, C., Bouyer, L. J., & Roy, J. (2019) · Sensors · doi:10.3390/s19081885 · Cited by 65 · see citing works
In-field instrumented ergonomic risk assessment: Inertial measurement units versus Kinect V2
Humadi, A., Nazarahari, M., Ahmad, R., & Rouhani, H. (2021) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2021.103147 · Cited by 60 · see citing works
Cudejko, T., Button, K., & Al-Amri, M. (2022) · Scientific Reports · doi:10.1038/s41598-022-18845-x · Cited by 60 · see citing works
Paolo, S. D., Nijmeijer, E. M., Bragonzoni, L., Dingshoff, E., Gokeler, A., & Benjaminse, A. (2022) · European Journal of Sport Science · doi:10.1080/17461391.2022.2064771 · Cited by 58 · see citing works
Hindle, B. R., Keogh, J., & Lorimer, A. V. (2021) · Applied Bionics and Biomechanics · doi:10.1155/2021/6628320 · Cited by 57 · see citing works
Maurer, C., Holzgreve, F., Fraeulin, L., Betz, W., Erbe, C., Brueggmann, D., Wanke, E. M., Nienhaus, A., Groneberg, D. A., & Ohlendorf, D. (2021) · Sensors · doi:10.3390/s21124077 · Cited by 57 · see citing works
Yamamoto, M., Shimatani, K., Hasegawa, M., Kurita, Y., Ishige, Y., & Takemura, H. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3135879 · Cited by 57 · see citing works
Validation of the Perception Neuron system for full-body motion capture
Choo, C. Z. Y., Chow, J. Y., & Komar, J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0262730 · Cited by 57 · see citing works
Semi-Automatic Sensor-to-Body Calibration of Inertial Sensors on Lower Limb Using Gait Recording
Nazarahari, M., & Rouhani, H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2939981 · Cited by 57 · see citing works
Noninvasive spinal stimulation safely enables upright posture in children with spinal cord injury
Keller, A., Singh, G., Sommerfeld, J. H., King, M., Parikh, P., Ugiliweneza, B., D’Amico, J. M., Gerasimenko, Y., & Behrman, A. L. (2021) · Nature Communications · doi:10.1038/s41467-021-26026-z · Cited by 56 · see citing works
Accuracy and Acceptability of Wearable Motion Tracking for Inpatient Monitoring Using Smartwatches
Auepanwiriyakul, C., Waibel, S., Songa, J., Bentley, P., & Faisal, A. A. (2020) · Sensors · doi:10.3390/s20247313 · Cited by 56 · see citing works
Tavassolian, M., Cuthbert, T. J., Napier, C., Peng, J., & Menon, C. (2020) · Advanced Intelligent Systems · doi:10.1002/aisy.201900165 · Cited by 55 · see citing works
van der Straaten, R., Baets, L. D., Jonkers, I., & Timmermans, A. A. A. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.10.005 · Cited by 54 · see citing works
Brouwer, N. P., Yeung, T., Bobbert, M. F., & Besier, T. F. (2020) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.13851 · Cited by 51 · see citing works
A “Smart” Undershirt for Tracking Upper Body Motions: Task Classification and Angle Estimation
Esfahani, M. I. M., & Nussbaum, M. A. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2859626 · Cited by 50 · see citing works
Brandt, M., Madeleine, P., Samani, A., Ajslev, J. Z. N., Jakobsen, M. D., Sundstrup, E., & Andersen, L. L. (2018) · Journal of Medical Internet Research · doi:10.2196/10272 · Cited by 50 · see citing works
Humadi, A., Nazarahari, M., Ahmad, R., & Rouhani, H. (2020) · IEEE Access · doi:10.1109/access.2020.3048645 · Cited by 48 · see citing works
Doğan, M., Koçak, M., Kılınç, Ö. O., Ayvat, F., Sütçü, G., Ayvat, E., Kılınç, M., Ünver, Ö., & Yıldırım, S. A. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.02.024 · Cited by 48 · see citing works
Accuracy of Base of Support Using an Inertial Sensor Based Motion Capture System
Guo, L., & Xiong, S. (2017) · Sensors · doi:10.3390/s17092091 · Cited by 46 · see citing works
Reliability of Xsens IMU-Based Lower Extremity Joint Angles during In-Field Running
Debertin, D., Wargel, A., & Mohr, M. (2024) · Sensors · doi:10.3390/s24030871 · Cited by 45 · see citing works
A survey of human shoulder functional kinematic representations
Krishnan, R., Björsell, N., Gutierrez-Farewik, E. M., & Smith, C. (2018) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-018-1903-3 · Cited by 45 · see citing works
Assessment of the measurement accuracy of inertial sensors during different tasks of daily living
Mundt, M., Thomsen, W., David, S., Dupré, T., Bamer, F., Potthast, W., & Markert, B. A. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.12.023 · Cited by 45 · see citing works
Wearable Sensor Network for Biomechanical Overload Assessment in Manual Material Handling
Giannini, P., Bassani, G., Avizzano, C. A., & Filippeschi, A. (2020) · Sensors · doi:10.3390/s20143877 · Cited by 45 · see citing works
Measures of Interjoint Coordination Post-stroke Across Different Upper Limb Movement Tasks
Schwarz, A., Veerbeek, J. M., Held, J. P. O., Buurke, J. H., & Luft, A. R. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.620805 · Cited by 45 · see citing works
Shuai, Z., Dong, A., Liu, H., & Cui, Y. (2022) · Sensors · doi:10.3390/s22030863 · Cited by 43 · see citing works
Influence of BMI on Gait Characteristics of Young Adults: 3D Evaluation Using Inertial Sensors
Rosso, V., Agostini, V., Takeda, R., TADANO, S., & Gastaldi, L. (2019) · Sensors · doi:10.3390/s19194221 · Cited by 43 · see citing works
Health and productivity impact of semi-automated work systems in construction
Ryu, J., McFarland, T. C., Banting, B. R., Haas, C. T., & Abdel-Rahman, E. M. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103396 · Cited by 43 · see citing works
IMU-Based Systems for Upper-Limb Kinematic Analysis in Clinical Applications: A Systematic Review
Favata, A., Gallart-Agut, R., Pàmies‐Vilà, R., Carme Torras, A., & Font-Llagunes, J. M. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3436532 · Cited by 42 · see citing works
Accuracy of angular displacements and velocities from inertial-based inclinometers
Chen, H., Schall, M. C., & Fethke, N. B. (2017) · Applied Ergonomics · doi:10.1016/j.apergo.2017.09.007 · Cited by 41 · see citing works
Bessone, V., Höschele, N., Schwirtz, A., & Seiberl, W. (2019) · Sports Biomechanics · doi:10.1080/14763141.2019.1671486 · Cited by 40 · see citing works
Chen, H., Schall, M. C., & Fethke, N. B. (2020) · Applied Ergonomics · doi:10.1016/j.apergo.2020.103187 · Cited by 38 · see citing works
Validity of inertial measurement units for tracking human motion: a systematic review
Ghattas, J., & Jarvis, D. N. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1990383 · Cited by 37 · see citing works
Cerfoglio, S., Capodaglio, P., Rossi, P., Conforti, I., D’Angeli, V., Milani, E., Galli, M., & Cimolin, V. (2023) · Sensors · doi:10.3390/s23136156 · Cited by 37 · see citing works
Muller, A., Pontonnier, C., Robert‐Lachaine, X., Dumont, G., & Plamondon, A. (2019) · Applied Ergonomics · doi:10.1016/j.apergo.2019.102935 · Cited by 37 · see citing works
Self-citationValidity and reliability of inertial sensors for elbow and wrist range of motion assessment
Costa, V., Ramírez, O. E. M., Otero, A., Muñoz‐García, D., Uribarri, S., & Raya, R. (2020) · PeerJ · doi:10.7717/peerj.9687 · Cited by 37 · see citing works
Zabat, M., Ababou, A., Ababou, N., & Dumas, R. (2019) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02033-7 · Cited by 36 · see citing works
Robert‐Lachaine, X., Parent, G., Fuentes, A., Hagemeister, N., & Aïssaoui, R. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.01.029 · Cited by 36 · see citing works
Self-citationAnalysis of the Limits of Automated Rule-Based Ergonomic Assessment in Bricklaying
Ryu, J., Diraneyya, M. M., Haas, C. T., & Abdel-Rahman, E. M. (2020) · Journal of Construction Engineering and Management · doi:10.1061/(asce)co.1943-7862.0001978 · Cited by 35 · see citing works
Hubaut, R., Guichard, R., Greenfield, J., & Blandeau, M. (2022) · Sensors · doi:10.3390/s22020436 · Cited by 35 · see citing works
Koopman, A. S., Kingma, I., Faber, G. S., Bornmann, J., & van Dieën, J. H. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.10.001 · Cited by 34 · see citing works
Concurrent validity of an inertial measurement system in tennis forehand drive
Pedro, B., Cabral, S., & Veloso, A. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110410 · Cited by 34 · see citing works
Warmerdam, E., Romijnders, R., Geritz, J., Elshehabi, M., Maetzler, C., Otto, J. C., Reimer, M., Stürner, K. H., Baron, R., Paschen, S., et al. (2021) · Sensors · doi:10.3390/s21175833 · Cited by 34 · see citing works
Accuracy of identification of low or high risk lifting during standardised lifting situations
Brandt, M., Madeleine, P., Samani, A., Jakobsen, M. D., Skals, S., Vinstrup, J., & Andersen, L. L. (2017) · Ergonomics · doi:10.1080/00140139.2017.1408857 · Cited by 34 · see citing works
Comparative Analysis of Markerless Motion Capture Systems for Measuring Human Kinematics
Ceriola, L., Taborri, J., Donati, M., Rossi, S., Patanè, F., & Mileti, I. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3431873 · Cited by 33 · see citing works
Cuadrado, J., Michaud, F., Lugrís, U., & Soto, M. P. (2021) · Sensors · doi:10.3390/s21020427 · Cited by 33 · see citing works
Fraeulin, L., Holzgreve, F., Brinkbäumer, M., Dziuba, A., Friebe, D., Klemz, S., Schmitt, M., Anna-Lena Theis, A., Tenberg, S., van Mark, A., et al. (2020) · PLoS ONE · doi:10.1371/journal.pone.0243646 · Cited by 32 · see citing works
Wagner, J. F. (2018) · Gyroscopy and Navigation · doi:10.1134/s2075108718010091 · Cited by 32 · see citing works
Fleron, M. K., Ubbesen, N. C. H., Battistella, F., Dejtiar, D. L., & Oliveira, A. S. (2018) · Sports Biomechanics · doi:10.1080/14763141.2017.1409259 · Cited by 31 · see citing works
Rezaei, A., Cuthbert, T. J., Gholami, M., & Menon, C. (2019) · Sensors · doi:10.3390/s19194288 · Cited by 31 · see citing works
Cerfoglio, S., Galli, M., Tarabini, M., Bertozzi, F., Sforza, C., & Zago, M. (2021) · Sensors · doi:10.3390/s21227709 · Cited by 30 · see citing works
Adamowicz, L., Gurchiek, R. D., Ferri, J., Ursiny, A. T., Fiorentino, N. M., & McGinnis, R. S. (2019) · Sensors · doi:10.3390/s19235143 · Cited by 30 · see citing works
Motor Control Training for the Shoulder with Smart Garments
Wang, Q., Baets, L. D., Timmermans, A. A. A., Chen, W., Giacolini, L., Matheve, T., & Markopoulos, P. (2017) · Sensors · doi:10.3390/s17071687 · Cited by 30 · see citing works
Meng, L., Martínez-Hernández, U., Childs, C. R., Dehghani-Sanij, A. A., & Buis, A. W. P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2938764 · Cited by 29 · see citing works
Guignard, B., Ayad, O., Baillet, H., Mell, F., Escobar, D. S., Boulanger, J., & Seifert, L. (2021) · Sports Biomechanics · doi:10.1080/14763141.2021.1945136 · Cited by 29 · see citing works
Changes in body position on the bike during seated sprint cycling: Applications to bike fitting
Bini, R. R., Daly, L., & Kingsley, M. (2019) · European Journal of Sport Science · doi:10.1080/17461391.2019.1610075 · Cited by 27 · see citing works
Does fatigue affect the kinematics of shooting in female basketball?
Li, F., Li, Z., Borović, I., Rupčić, T., & Knjaz, D. (2021) · International Journal of Performance Analysis in Sport · doi:10.1080/24748668.2021.1945878 · Cited by 27 · see citing works
Forces: A Motion Capture-Based Ergonomic Method for the Today’s World
Marín, J., & Marín, J. J. (2021) · Sensors · doi:10.3390/s21155139 · Cited by 27 · see citing works
McCabe, M. V., Citters, D. W. V., & Chapman, R. M. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2044028 · Cited by 27 · see citing works
Wearable inertial sensors for objective kinematic assessments: A brief overview
Schall, M. C., Chen, H., & Cavuoto, L. A. (2022) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2022.2100407 · Cited by 27 · see citing works
Bae, K., Lee, S., Bak, S.-Y., Kim, H. S., Ha, Y., & You, J. H. (2024) · Scientific Reports · doi:10.1038/s41598-024-79707-2 · Cited by 26 · see citing works
Weitbrecht, M., Holzgreve, F., Fraeulin, L., Haenel, J., Betz, W., Erbe, C., Maurer, C., Wanke, E. M., Brueggmann, D., Nienhaus, A., et al. (2022) · Human Factors The Journal of the Human Factors and Ergonomics Society · doi:10.1177/00187208211053073 · Cited by 26 · see citing works
Ghaffari, A., Rahbek, O., Lauritsen, R. E. K., Kappel, A., Kold, S., & Rasmussen, J. (2022) · Sensors · doi:10.3390/s22145289 · Cited by 26 · see citing works
Hughes, C. M. L., Louie, A., Sun, S., Gordon-Murer, C., Belay, G. J., Baye, M., & Zhang, X. (2019) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2019.00322 · Cited by 25 · see citing works
Kim, D., Jin, Y., Cho, H., Jones, T., Zhou, Y. M., Fadaie, A., Popov, D., Swaminathan, K., & Walsh, C. J. (2025) · Nature Communications · doi:10.1038/s41467-025-58624-6 · Cited by 24 · see citing works
Giraldo-Pedroza, A., Lee, W. C. C., Lam, W., Coman, R. L., & Alıcı, G. (2020) · Sensors · doi:10.3390/s20226637 · Cited by 24 · see citing works
Quantification of Error Sources with Inertial Measurement Units in Sports
Kamstra, H., Wilmes, E., & van der Helm, F. C. T. (2022) · Sensors · doi:10.3390/s22249765 · Cited by 24 · see citing works
A passive upper-limb exoskeleton reduced muscular loading during augmented reality interactions
Kong, Y., Park, S., Shim, J.-W., Choi, K., Shim, H.-H., Kia, K., & Kim, J. H. (2023) · Applied Ergonomics · doi:10.1016/j.apergo.2023.103982 · Cited by 24 · see citing works
Motion-Based Prediction of Hands and Feet Contact Efforts During Asymmetric Handling Tasks
Muller, A., Pontonnier, C., & Dumont, G. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2913308 · Cited by 24 · see citing works
- Authors
- Robert-Lachaine, X., Mecheri, H., Larue, C., & Plamondon, A.
- Affiliations
- Institut de recherche Robert-Sauvé en santé et en sécurité du travail (CA)
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2016-07-05
- Volume
- 55
- Issue
- 4
- Pages
- 609-619
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2460830751
- Cited by
- 329
- References
- 36
- Citations by year
- 2026: 27 · 2025: 39 · 2024: 29 · 2023: 35 · 2022: 42 · 2021: 46 · 2020: 43 · 2019: 29 · 2018: 23 · 2017: 16
- FWCI
- 35.71
- Type
- journal article
- Language
- en
- Open access
- green
- pharesst.irsst.qc.ca
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- PhareSST (submittedVersion)
- Funders
- IRSST (2012-0040, Postdoctoral program)
- Topics
- Social Sciences › Psychology › Social Psychology › Ergonomics and Musculoskeletal Disorders
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, optical motion capture, whole-body kinematics, technological errors, joint angles, task complexity, task duration, manual material handling, functional movement, local coordinate system, anatomical landmarks, Xsens, human factors, worker tracking
- MeSH terms
- Adult, Biomechanical Phenomena, Female, Humans, Male, Models, Theoretical, Monitoring, Physiologic, Motion, Movement, Posture, Optics and Photonics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review