Risk Analysis of Blood Glucose Data: A Quantitative Approach to Optimizing the Control of Insulin Dependent Diabetes
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Patients with Insulin‐Dependent Diabetes are continuously involved in a clinical optimization process: to maintain strict glycemic control without increasing their risk for hypoglycemia. This study offers quantitative tools for on‐line assessment of the quality of this optimization, based on self‐monitoring of blood glucose (SMBG). Ninety‐six adults with Insulin Dependent Diabetes Mellitus (IDDM), age 35 ± 8 yrs., duration of diabetes 16 ± 10 yrs., HbA lc 8.6 ± 1.8%, 43 of whom had a recent history of severe hypoglycemia (SH), while 53 did not, used Lifescan One Touch II meters for 135 ± 53 SMBG readings over a month. For the following six months the subjects recorded occurrence of SH. The two patient groups, with and without a history of SH, did not differ in age, duration of diabetes, HbA lc, insulin units/day, average BG or BG variability. We suggest a computational procedure based on a symmetrization of the BG measurement scale and on a superimposed BG risk function, that allows for computation of two glycemic control markers: the Low BG Index (LBGI) and the High BG Index (HBGI). The LBGI is associated with SH: the LBGI and the rate of change of the BG risk, classified correctly 77% of the subjects with vs. without a history of SH and accounted for 46% of the variance of future SH. The HBGI, in combination with age, duration of diabetes and daily insulin dose, accounted for 57% of the variance of patients′ glycosylated hemoglobin. We conclude that the LBGI and the HBGI are accurate on‐line SMBG measures for patients′ glycemic control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
Hypoglycemia in the Diabetes Control and Complications Trial
The Diabetes Control and Complications Trial Research Group (1997) · Diabetes · doi:10.2337/diab.46.2.271 · Cited by 746
Cryer, P. E., Fisher, J. N., & Shamoon, H. (1994) · Diabetes Care · doi:10.2337/diacare.17.7.734 · Cited by 159
Reichard, P., & Pihl, M. (1994) · Diabetes · doi:10.2337/diab.43.2.313 · Cited by 147
Kovatchev, B. P., Farhy, L. S., Cox, D. J., Straume, M., Yankov, V. I., Gonder-Frederick, L. A., & Clarke, W. L. (1999) · Computational and Mathematical Methods in Medicine · doi:10.1080/10273669908833028 · Cited by 17
Self-citation
Cited by
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
Self-citationDiabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“27 visualizes this concept by a 72-hour CGM trace of a patient with T1DM: each CGM reading is processed in two steps: 1) application of the symmetrization formula [184], and 2) application of the quadratic risk function that assigns increasing weights to larger BG deviations towards hypo- or hyper-glycemia [185].”
Self-citationMetrics for glycaemic control - from HbA1c to continuous glucose monitoring
Kovatchev, B. P. (2017) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2017.3 · Cited by 272
Self-citationGlucose Variability: Timing, Risk Analysis, and Relationship to Hypoglycemia in Diabetes
Kovatchev, B., & Cobelli, C. (2016) · Diabetes Care · doi:10.2337/dc15-2035 · Cited by 255
Self-citationStatistical Tools to Analyze Continuous Glucose Monitor Data
Clarke, W., & Kovatchev, B. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0138 · Cited by 249
“15 It has been shown that this categorization is particularly powerful for identifying people at risk for hypoglycemia—subjects at minimal risk experience prospectively zero severe hypoglycemic episodes and zero extreme low BG readings (below 40mg = dL) during a 3-month follow-up, whereas subjects…”
Self-citationKovatchev, B. P., Clarke, W. L., Breton, M., Brayman, K., & McCall, A. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.849 · Cited by 201
Self-citationModular Closed-Loop Control of Diabetes
Patek, S. D., Magni, L., Dassau, E., Hughes-Karvetski, C., Toffanin, C., De Nicolao, G., Del Favero, S., Breton, M., Man, C. D., Renard, E., et al. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2192930 · Cited by 180
“The SSM uses all available glucose and insulin data (explicitly accounting for active insulin) in estimating the risk of hypoglycemia using the risk scale proposed in [36].”
MethodSelf-citationLaurenzi, A., Bolla, A. M., Panigoni, G., Doria, V., Uccellatore, A., Peretti, E., Saibene, A., Galimberti, G., Bosi, E., & Scavini, M. (2011) · Diabetes Care · doi:10.2337/dc10-1490 · Cited by 120
“Capillary glucose measurements were downloaded from the memory of glucose meters at 12 and 24 weeks at the time of the outpatient visits, and LBGI and HBGI were calculated as reported (17).”
Rama Chandran, S., Tay, W. L., Lye, W. K., Lim, L. L., Ratnasingam, J., Tan, A. T. B., & S.L. Gardner, D. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2017.0388 · Cited by 114
Bosi, E., Scavini, M., Ceriello, A., Cucinotta, D., Tiengo, A., Marino, R., Bonizzoni, E., Giorgino, F., & on behalf of the PRISMA Study Group (2013) · Diabetes Care · doi:10.2337/dc13-0092 · Cited by 105
Visentin, R., Dalla Man, C., Kovatchev, B., & Cobelli, C. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0377 · Cited by 103
Self-citationA Dual Mode Adaptive Basal-Bolus Advisor Based on Reinforcement Learning
Sun, Q., Jankovic, M. V., Budzinski, J., Moore, B., Diem, P., Stettler, C., & Mougiakakou, S. G. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2887067 · Cited by 69
Are risk indices derived from CGM interchangeable with SMBG-Based indices?
Fabris, C., Patek, S. D., & Breton, M. D. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815599177 · Cited by 52
“Based on a structured theory of risk analysis of BG data presented in Kovatchev et al.(3), performance of glycemic control was widely assessed using LBGI/HBGI(9,10), and 2 diabetes-specific computational algorithms were designed to predict probability of future hypoglycemic events and HbA1c levels(11-14), which establ…”
BackgroundMethodInfluentialGarcia-Tirado, J., Diaz, J. L., Esquivel-Zuniga, R., Koravi, C. L. K., Corbett, J. P., Dawson, M., Wakeman, C., Barnett, C. L., Oliveri, M. C., Myers, H., et al. (2021) · Diabetes Care · doi:10.2337/dc21-0932 · Cited by 52
Reduced daily risk of glycemic variability: comparison of exenatide with insulin glargine
McCall, A. L., Cox, D. J., Brodows, R., Crean, J., Johns, D., & Kovatchev, B. (2009) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2008.0107 · Cited by 46
“0).(15) The ADRR reflects the risk of combined high and low glucose variability.”
BackgroundSelf-citationVisentin, R., Giegerich, C., Jäger, R., Dahmen, R., Boss, A., Grant, M., Dalla Man, C., Cobelli, C., & Klabunde, T. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0128 · Cited by 36
Pfützner, A., Weissmann, J., Mougiakakou, S., Daskalaki, E., Weis, N., & Ziegler, R. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0278 · Cited by 19
Kovatchev, B., Umpierrez, G., DiGenio, A., Zhou, R., & Inzucchi, S. E. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296815587014 · Cited by 18
Self-citation
Metadata
- Authors
- Kovatchev, B. P., Straume, M., Cox, D. J., & Farhy, L. S.
- Venue
- Computational and Mathematical Methods in Medicine
- Publisher
- Wiley
- Published
- 2000-01
- Volume
- 3
- Issue
- 1
- Pages
- 1-10
- ISSN
- 1748-670X (ISSN-L)
- 1748-6718
- OpenAlex
- W2083218162
- Cited by
- 125
- References
- 5
- FWCI
- 0.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.