CoChat

Lower Extremity Applications of Functional Neuromuscular Stimulation

Jaeger, Robert J. · 1992 · Assistive Technology
Cited by 46

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Functional electrical stimulation (FES) applications in the lower extremity are common in research laboratories, but clinical applications are minimal. This review summarizes current knowledge with respect to clinical application. When electrical stimulation is used in clinical applications for functional movement such as standing and walking, it is typically applied in an open-loop manner; a predetermined stimulus pattern is delivered regardless of the consequences of the actual movement. Few clinical applications of FES involve closed-loop control because of the numerous difficulties involved in its application. As with any volitional muscle contraction, electrically stimulated muscle contractions will exhibit fatigue. Although the dynamics of fatigue may differ, electrically stimulated muscle contractions cannot be continuously sustained, and if the duty cycle is too severe, even alternating periods of rest and contraction cannot be sustained at a constant force level. The exact nature of fatigue is highly specific to the past history of the individual muscle and to the individual subject. Despite their intricate detail, quantitative modeling studies have not yet been applied extensively to clinical applications. Present implantable systems are not yet a viable option for clinical application. It is not clear whether more success with surface or percutaneous systems must first be achieved to justify implantation or whether greater improvements in implantable technology and surgical protocols are needed before implantable systems will become practical. It is clear that almost any reasonably designed stimulation protocol will increase muscle bulk. The existence of other therapeutic benefits and their cost/benefit ratios remain to be fully established. It is possible to stand through bilateral stimulation of the quadriceps. Using surface electrodes, this technique is achievable in any physical therapy clinic having minimal expertise in neuromuscular stimulation. FES-aided standing must be conducted as a research project with a protocol approved by the local institutional review board, as there are currently no FDA-approved stimulation devices for standing. Multichannel FES systems are not currently available for clinical application in the United States. This may change if the "Parastep" system receives FDA approval. Percutaneous and implanted systems are years away from commercialization and clinical availability. Hybrid systems, based primarily on the reciprocating gait orthosis (RGO), are presently the only clinically available form of walking that includes some form of FES assistance. The costs and benefits of adding FES to the RGO and the long-term user acceptance rate for these systems remain to be determined.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10400435.1992.10132189

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 46

Metadata

Authors
Jaeger, R. J.
Venue
Assistive Technology
Published
1992-06-30
Volume
4
Issue
1
Pages
19-30
ISSN
  • 1040-0435 (ISSN-L)
  • 1949-3614
OpenAlex
W2073774203
Cited by
46
References
4
FWCI
1.68
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Lower Extremity Applications of Functional Neuromuscular Stimulation. https://app.cochat.ai/papers/10.1080/10400435.1992.10132189
The paper
Jaeger, R. J. (1992). Lower Extremity Applications of Functional Neuromuscular Stimulation. Assistive Technology. https://doi.org/10.1080/10400435.1992.10132189

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.