Delta Checks in the clinical laboratory
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
International standards and practice guidelines recommend the use of delta check alerts for laboratory test result interpretation and quality control. The value of contemporary applications of simple univariate delta checks determined as an absolute change, percentage change, or rate of change to recognize specimen misidentification or other laboratory errors has not received much study. This review addresses these three modes of calculation, but in line with the majority of published work, most attention is focused on the identification of specimen misidentification errors. Investigation of delta check alerts are time-consuming and the yield of identified errors is usually small compared to the number of delta check alerts; however, measured analytes with low indices of individuality frequently perform better. While multivariate approaches to delta checks suggest improved usefulness over simple univariate delta check strategies, some of these are complex and not easily applied in contemporary laboratory information systems and middleware. Nevertheless, a simple application of delta checks may hold value in identifying clinically significant changes in several clinical situations: for acute kidney injury using changes in serum creatinine, for risk of osmotic demyelination syndrome using rapid acute changes in serum sodium levels, or for early triage of chest pain patients using high sensitivity troponin assays. A careful and highly selective approach to identifying delta check analytes, calculation modes, and thresholds before putting them into practice is warranted; then follow-up with careful monitoring of performance and balancing true positives, false negatives, and false positives among delta check alerts is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roffi, M., Patrono, C., Collet, J.-P., Mueller, C., Valgimigli, M., Andreotti, F., Bax, J. J., Borger, M. A., Brotons, C., Chew, D. P., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehv320 · Cited by 8,261
Bonini, P., Plebani, M., Ceriotti, F., & Rubboli, F. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.5.691 · Cited by 850
Sandberg, S., Fraser, C. G., Horvath, A. R., Jansen, R., Jones, G., Oosterhuis, W., Petersen, P. H., Schimmel, H., Sikaris, K., & Panteghini, M. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0067 · Cited by 563
Apple, F. S., Sandoval, Y., Jaffe, A. S., & Ordonez-Llanos, J. (2017) · Clinical Chemistry · doi:10.1373/clinchem.2016.255109 · Cited by 408
Fraser, C. G. (2012) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2011.733 · Cited by 286 · cited 2×
“The simplest approach to calculating the RCV limits involves using in-laboratory analytical imprecision (CVA, analytical variability) for a test analyte and published estimates of intra-individual variability (CVI) obtained from available sources [40], where CVI denotes intraindividual variability, the variability res…”
BackgroundClinical Use of High-Sensitivity Cardiac Troponin in Patients With Suspected Myocardial Infarction
Twerenbold, R., Boeddinghaus, J., Nestelberger, T., Wildi, K., Rubini Gimenez, M., Badertscher, P., & Mueller, C. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.07.718 · Cited by 255
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233 · cited 2×
“Medicine Working Group on Biological Variation and Task and Finish Group for the Biological Variation Database published a checklist for selecting robust estimates of biological variability [48].”
BackgroundMethodVariability of biomarkers in patients with chronic heart failure and healthy controls
Meijers, W. C., van der Velde, A. R., Muller Kobold, A. C., Dijck-Brouwer, J., Wu, A. H., Jaffe, A., & de Boer, R. A. (2017) · European Journal of Heart Failure · doi:10.1002/ejhf.669 · Cited by 146 · cited 1×
“detecting renal transplant rejection [87,88]; for detecting and monitoring heart failure [29,89,90]; in the diagnosis and monitoring of irritable bowel disease [91]; to assist with interpretation of tumor marker results [92–95]; for monitoring monoclonal gammopathies”
BackgroundThe use of reference change values in clinical laboratories
Bugdayci, G., Oguzman, H., Arattan, H., & Sasmaz, G. (2015) · Clinical Laboratory · doi:10.7754/clin.lab.2014.140906 · Cited by 21
Cited by
Identifying mislabelled samples: Machine learning models exceed human performance
Farrell, C.-J. (2021) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/00045632211032991 · Cited by 35
“Current laboratory practice is to use delta checks to screen for these errors and have results failing delta checks manually reviewed by laboratory staff.(1) Preliminary investigations have demonstrated that machine learning (ML) models are superior to delta checks in identifying mislabelled samples.”
BackgroundZhou, R., Liang, Y.-F., Cheng, H.-L., Wang, W., Huang, D.-W., Wang, Z., Feng, X., Han, Z.-W., Song, B., Padoan, A., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1171 · Cited by 28
“…DC rules can be combined according to the common test panel, and the interpretationofDClimits fora grouped testpanel should be different from a single analyte, since the number of hypothesis tests (i.e. the number of DC rules) applied is much higher and should be taken into account [8, 10].”
BackgroundDecision support or autonomous artificial intelligence? The case of wrong blood in tube errors
Farrell, C.-J. L. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0873 · Cited by 12
Metadata
- Authors
- Randell, E. W., & Yenice, S.
- Venue
- Critical Reviews in Clinical Laboratory Sciences
- Publisher
- Informa UK Limited
- Published
- 2019-01-11
- Volume
- 56
- Issue
- 2
- Pages
- 75-97
- ISSN
- 1040-8363 (ISSN-L)
- 1549-781X
- OpenAlex
- W2909201036
- Cited by
- 65
- References
- 9
- FWCI
- 1.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delta Checks in the clinical laboratory. https://app.cochat.ai/papers/10.1080/10408363.2018.1540536
- The paper
- Randell, E. W., & Yenice, S. (2019). Delta Checks in the clinical laboratory. Critical Reviews in Clinical Laboratory Sciences. https://doi.org/10.1080/10408363.2018.1540536
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.