A comparison between wet and cryogenic drilling of CFRP/Ti stacks
The DOI matches its Crossref record.
Abstract
This paper compares conventional and cryogenic cooling in the deep hole drilling of carbon fiber reinforced polymer (CFRP)/Ti stacks. Various parameters are taken into account to find if the use of cryogenic coolant is justified by the improvement of the final results. Both the thrust and the torque were acquired continuously during the machining operations and compared both in average and distribution. The use of a cryogenic coolant brings a reduction in thrust force and torque without any sensible drawback. Overall the results prove that cryogenic drilling is a suitable technology for CFRP/Ti stack drill.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Carbon fiber reinforced polymer in drilling: From damage mechanisms to suppression
Gao, T., Li, C., Wang, Y., Liu, X., An, Q., Li, H. N., Zhang, Y., Cao, H., Liu, B., Wang, D., et al. (2022) · Composite Structures · doi:10.1016/j.compstruct.2022.115232 · Cited by 275
Khanna, N., Agrawal, C., Pimenov, D. Y., Singla, A. K., Machado, A. R., da Silva, L. R. R., Gupta, M. K., Sarikaya, M., & Krolczyk, G. M. (2021) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2021.05.053 · Cited by 216
A critical review addressing drilling-induced damage of CFRP composites
Xu, J., Yin, Y., Paulo Davim, J., Li, L., Ji, M., Geier, N., & Chen, M. (2022) · Composite Structures · doi:10.1016/j.compstruct.2022.115594 · Cited by 200
Experimental study on mechanical drilling of carbon/epoxy composite-Ti6Al4V stacks
Xu, J., Zhou, L., Chen, M., & Ren, F. (2019) · Materials and Manufacturing Processes · doi:10.1080/10426914.2019.1594275 · Cited by 80
Investigation of minimum quantity lubrication effects in drilling CFRP/Ti6Al4V stacks
Xu, J., Ji, M., Chen, M., & Ren, F. (2019) · Materials and Manufacturing Processes · doi:10.1080/10426914.2019.1661431 · Cited by 73
“Among the family of the composite-metal stacks, CFRP/Ti6Al4V stacks are mainly the representative configuration being widely used in the class of multi-material systems.([9]) Despite their widespread applications, the compound materials possess a very poor machinability since each material layer shows completely diffe…”
Background
Metadata
- Authors
- Impero, F., Dix, M., Squillace, A., Prisco, U., Palumbo, B., & Tagliaferri, F.
- Venue
- Materials and Manufacturing Processes
- Publisher
- Informa UK Limited
- Published
- 2018-04-18
- Volume
- 33
- Issue
- 12
- Pages
- 1354-1360
- ISSN
- 1042-6914 (ISSN-L)
- 1532-2475
- OpenAlex
- W2800475774
- Cited by
- 75
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A comparison between wet and cryogenic drilling of CFRP/Ti stacks. https://app.cochat.ai/papers/10.1080/10426914.2018.1453162
- The paper
- Impero, F., Dix, M., Squillace, A., Prisco, U., Palumbo, B., & Tagliaferri, F. (2018). A comparison between wet and cryogenic drilling of CFRP/Ti stacks. Materials and Manufacturing Processes. https://doi.org/10.1080/10426914.2018.1453162
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.