CoChat

Indoor Environmental Quality in Six Commercial Office Buildings in the Midwest United States

Reynolds, Stephen J., Black, Donald W., Borin, Stanley S., Breuer, George, Burmeister, Leon F., Fuortes, Laurence J., Smith, Theodore F., Stein, Matthew A., Subramanian, P., Thorne, Peter S., Whitten, Paul · 2001 · Applied Occupational and Environmental Hygiene
Cited by 131

The DOI matches its Crossref record.

Abstract

The aims of this study were to characterize physical, mechanical, and environmental factors influencing indoor environmental quality (IEQ) in commercial office buildings; document occupant perceptions and psychosocial attributes; and evaluate relationships among these parameters. Six large office buildings in metropolitan areas were selected in Iowa, Minnesota, and Nebraska. Comprehensive sampling was conducted over one week in each building, during all four seasons. This paper presents the study methods and selected results from the first round of sampling (November 1996 to April 1997). Air flow and recirculation rates were quite variable, with the proportion of outdoor air provided to occupants ranging from 10 to 79 CFM/person. Carbon dioxide, carbon monoxide, and temperature were within ranges anticipated for nonproblem buildings. Relative humidity was low, ranging from 11.7 to 24.0 percent. Indoor geometric mean concentrations of total volatile organic compounds (TVOCs) ranged from 73 to 235 microg/m3. The most prevalent compounds included xylene, toluene, 2-propanol, limonene, and heptane. Geometric mean formaldehyde concentrations ranged from 1.7 to 13.3 microg/m3, and mean acetaldehyde levels ranged from <3.0 to 7.5 microg/m3. Airborne concentrations of culturable bacteria and fungi were low, with no samples exceeding 150 CFU/m3. Total (direct count) bioaerosols were more variable, ranging from 5010 to 10,700 organisms/m3. Geometric mean endotoxin concentrations ranged from 0.5 to 3.0 EU/m3. Respirable particulates (PM10) were low (14 to 36 microg/m3). Noise levels ranged from 48 to 56 dBA, with mean light values ranging from 200 to 420 lux. Environmental parameters were significantly correlated with each other. The prevalence of upper respiratory symptoms (dry eyes, runny nose), central nervous system symptoms (headache, irritability), and musculoskeletal symptoms (pain/stiffness in shoulders/neck) were elevated compared to other studies using similar questionnaires. Importantly, psychosocial factors were significantly related to increased symptoms in females, while environmental factors were more closely correlated with symptoms in males. Endotoxin concentrations were associated with symptoms in both males and females. These data will help to identify and quantify the relative role of factors that contribute to sick building syndrome. The data collected in this study may also be used to evaluate the effectiveness of current building operation practices, and can be used to prioritize allocations of resources for reduction of risk associated with IEQ complaints.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/104732201753214170

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Reynolds, S. J., Black, D. W., Borin, S. S., Breuer, G., Burmeister, L. F., Fuortes, L. J., Smith, T. F., Stein, M. A., Subramanian, P., Thorne, P. S., & Whitten, P.
Venue
Applied Occupational and Environmental Hygiene
Published
2001-11
Volume
16
Issue
11
Pages
1065-1077
ISSN
  • 1047-322X (ISSN-L)
  • 1521-0898
OpenAlex
W2120244859
Cited by
131
References
0
FWCI
3.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.