CoChat

Biodegradable Polymers for Orthopedic Applications: Synthesis and Processability of Poly (l-Lactide) and Poly (Lactide-co-€-Caprolactone)

Zhang, Xichen, Pichora, David, Goosen, Mattheus F. A. · 1993 · Journal of Macromolecular Science, Part A
Cited by 43

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The synthesis of poly(l-lactide) (PLLA), poly(l-lactide-co-e-caprolactone), and poly(DL-lactide-co-e-caprolactone) by ring-opening bulk polymerization was investigated. Polymerization temperature had a significant effect on the PLLA molecular weight. At 184°C a polymer with a molecular weight of only 10 × 104 resulted. This was lower by a factor of 2 than that obtained at 103 and 145°C. The stannous octoate (SnOct) concentration, with a monomer/SnOct molar ratio in the range of 1,000 to 10,000, was not found to have a significant effect on the PLLA molecular weight. A heterogeneous structure in polymerized PLLA was observed. The intrinsic viscosity of poly(lactide-co-€-caprolactone), obtained at 130°C, monomer/SnOct molar ratio 5,000, and polymerization time of 30 hours, decreased with increasing €-caprolactone content within the first 9 wt% and then leveled off. Die-drawing of PLLA cylinders, for the purpose of increasing the polymer's mechanical strength, was unsuccessful due to the brittleness of the polymer. The drawability of poly(l-lactide), however, was greatly improved by copolymerization with €-caprolactone. With only 3 wt% of €-caprolactone, for example, the tensile strength of die-drawn poly(l-lactide-co-e-caprolactone) was increased by a factor of more than 3. Polymer processing temperature was also investigated. The requirement for low processing temperatures in melt manufacture of controlled release matrix devices containing thermal sensitive drugs was accomplished by three methods: through the use of low molecular weight poly(DL-lactide), adding (DL-lactic) acid oligomer to high molecular weight PDLLA, and copolymerizing DLLA with €-caprolactone. The glass transition temperatures of the modified high molecular weight PDLLA decreased significantly. Melt extrusion below 100°C could be performed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10601329308009437

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 43

Metadata

Authors
Zhang, X., Pichora, D., & Goosen, M. F. A.
Venue
Journal of Macromolecular Science, Part A
Published
1993-12
Volume
30
Issue
12
Pages
933-947
ISSN
  • 1060-1325 (ISSN-L)
  • 1520-5738
OpenAlex
W2066330701
Cited by
43
References
2
FWCI
4.13
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biodegradable Polymers for Orthopedic Applications: Synthesis and Processability of Poly (l-Lactide) and Poly (Lactide-co-€-Caprolactone). https://app.cochat.ai/papers/10.1080/10601329308009437
The paper
Zhang, X., Pichora, D., & Goosen, M. F. A. (1993). Biodegradable Polymers for Orthopedic Applications: Synthesis and Processability of Poly (l-Lactide) and Poly (Lactide-co-€-Caprolactone). Journal of Macromolecular Science, Part A. https://doi.org/10.1080/10601329308009437

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.