Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review
The DOI matches its Crossref record; 155 of the 155 references it cites were found in a registry or an index.
Abstract
The recalcitrant behavior of per- and polyfluoroalkyl substances (PFAS) to most traditional water treatment processes is driving the development of new or modified treatment approaches for PFAS destruction. This paper evaluates and compares the strengths and limitations of available physico-chemical treatment techniques. A comparative assessment based on effectiveness (extent of degradation and defluorination) and efficiency (rate, cost, and energy use) revealed that electrochemical oxidation, advanced reduction processes (ARPs) and plasma-based technology exhibited the best potential towards overall process efficiency. Sonolysis and heat-activated persulfate had the highest energy demand while photochemical oxidation was the most ineffective method.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Although many of these technologies have shown the ability to destroy select PFAS, none have demonstrated long-term performance approaching mineralization at full scale with natural- and industrial-water matrices for a wide assortment of PFAS.”
From Per- and polyfluoroalkyl substances in the environment (2022) · cites this paper as [156]
In the citing paper
“However, these methods suffer from drawbacks such as high costs, the use of high energy that can generate toxic transformation products, and concentration-based methods that need post-processing to completely destroy concentrated PFAS (Nzeribe et al., 2019).”
From A review of microbial degradation of per- and polyfluoroalkyl substances (PFAS): Biotransformation routes and enzymes (2023) · cites this paper as Nzeribe et al., 2019
In the citing paper
“The numerous physical and chemical treatment options for PFAS that have been developed are often accompanied by limitations, including high costs, high energy use, generation of hazardous transformation byproducts, and the need for additional post-processing (32).”
From Toward the development of a molecular toolkit for the microbial remediation of per-and polyfluoroalkyl substances (2024) · cites this paper as [32]
Citations
Cites
Buck, R. C., Franklin, J., Berger, U., Conder, J. M., Cousins, I. T., de Voogt, P., Jensen, A. A., Kannan, K., Mabury, S. A., & van Leeuwen, S. P. (2011) · Integrated Environmental Assessment and Management · doi:10.1002/ieam.258 · Cited by 4,641
Photochemical processes for water treatment
Legrini, O., Oliveros, E., & Braun, A. M. (1993) · Chemical Reviews · doi:10.1021/cr00018a003 · Cited by 3,580
Oller, I., Malato, S., & Sánchez-Pérez, J. A. (2011) · Science of The Total Environment · doi:10.1016/j.scitotenv.2010.08.061 · Cited by 2,406
Direct And Mediated Anodic Oxidation of Organic Pollutants
Panizza, M., & Cerisola, G. (2009) · Chemical Reviews · doi:10.1021/cr9001319 · Cited by 2,346
Advanced Oxidation Processes for Wastewater Treatment: Formation of Hydroxyl Radical and Application
WANG, J. L., & XU, L. J. (2012) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2010.507698 · Cited by 1,586 · cited 1×
“This is because, during sonolysis, thermal dissociation of molecular oxygen may occur in the bubble generating hydroxyl radicals Wang & Xu (2012), which react with IO4 - to form less effective IO4 , which acts as a scavenger of the IO3 radicals (Lee et al., 2016).”
Backgroundvon Gunten, U. (2003) · Water Research · doi:10.1016/s0043-1354(02)00458-x · Cited by 1,345
Electrohydraulic Discharge and Nonthermal Plasma for Water Treatment
Locke, B. R., Sato, M., Sunka, P., Hoffmann, M. R., & Chang, J.-S. (2006) · Industrial & Engineering Chemistry Research · doi:10.1021/ie050981u · Cited by 1,181
In Situ Chemical Oxidation of Contaminated Soil and Groundwater Using Persulfate: A Review
TSITONAKI, A., PETRI, B., CRIMI, M., MOSBÆK, H., SIEGRIST, R. L., & BJERG, P. L. (2010) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643380802039303 · Cited by 1,166
Self-citationBolton, J. R., Bircher, K. G., Tumas, W., & Tolman, C. A. (2001) · Pure and Applied Chemistry · doi:10.1351/pac200173040627 · Cited by 1,157
Radjenovic, J., & Sedlak, D. L. (2015) · Environmental Science & Technology · doi:10.1021/acs.est.5b02414 · Cited by 1,125
Research works printed but not linked: 3
- Hawley E. L., 2004, Chromium (VI) Handbook, 275, 309
- Herzke D., 2007, Literature survey of polyfluorinated organic compounds, phosphor containing flame retardants, 3-nitrobenzanthrone, organic tin compounds, platinum and silver
- Yasuoka K., 2010, International Journal of Plasma Environmental Science and Technology, 4, 113
Cited by
Per- and polyfluoroalkyl substances in the environment
Evich, M. G., Davis, M. J. B., McCord, J. P., Acrey, B., Awkerman, J. A., Knappe, D. R. U., Lindstrom, A. B., Speth, T. F., Tebes-Stevens, C., Strynar, M. J., et al. (2022) · Science · doi:10.1126/science.abg9065 · Cited by 2,157
“Other destructive treatments for aqueous streams include electrochemical degradation, sonolysis, non-thermal plasma, advanced oxidation (e.g., sulfate radicals) and reduction (solvated electrons), biodegradation (Feammox), zero-valent iron, hydrothermal, and supercritical-water oxidation (149, 156).”
Gagliano, E., Sgroi, M., Falciglia, P. P., Vagliasindi, F. G. A., & Roccaro, P. (2020) · Water Research · doi:10.1016/j.watres.2019.115381 · Cited by 1,249
Low-temperature mineralization of perfluorocarboxylic acids
Trang, B., Li, Y., Xue, X.-S., Ateia, M., Houk, K. N., & Dichtel, W. R. (2022) · Science · doi:10.1126/science.abm8868 · Cited by 425
PFAS and their substitutes in groundwater: Occurrence, transformation and remediation
Xu, B., Liu, S., Zhou, J. L., Zheng, C., Weifeng, J., Chen, B., Zhang, T., & Qiu, W. (2021) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2021.125159 · Cited by 369
Emerging technologies for PFOS/PFOA degradation and removal: A review
Leung, S. C. E., Shukla, P., Chen, D., Eftekhari, E., An, H., Zare, F., Ghasemi, N., Zhang, D., Nguyen, N.-T., & Li, Q. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.153669 · Cited by 334
Metadata
- Authors
- Nzeribe, B. N., Crimi, M., Mededovic Thagard, S., & Holsen, T. M.
- Affiliations
- Clarkson University (US)
- Chemical & Biomolecular Engineering, Clarkson University, Potsdam, NY, USA;
- Corresponding author
- Nzeribe, Blossom Nwedo
- Venue
- Critical Reviews in Environmental Science and Technology
- Publisher
- Informa UK Limited
- Published
- 2019-04-11
- Volume
- 49
- Issue
- 10
- Pages
- 866-915
- ISSN
- 1064-3389 (ISSN-L)
- 1547-6537
- OpenAlex
- W2937632433
- Cited by
- 314
- References
- 155
- Citations by year
- 2026: 47 · 2025: 56 · 2024: 52 · 2023: 36 · 2022: 52 · 2021: 40 · 2020: 25 · 2019: 6
- FWCI
- 13.40
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Critical Reviews in Environmental Science and Technology (publishedVersion)
- Topics
- Physical Sciences › Environmental Science › Environmental Chemistry › Per- and polyfluoroalkyl substances research
- Physical Sciences › Environmental Science › Water Science and Technology › Advanced oxidation water treatment
- Physical Sciences › Environmental Science › Environmental Engineering › Environmental remediation with nanomaterials
- Keywords
- per- and polyfluoroalkyl substances, PFAS removal, PFAS degradation, defluorination, electrochemical oxidation, advanced reduction processes, sonolysis, heat-activated persulfate, photooxidation, energy demand, treatment costs, water treatment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review. https://app.cochat.ai/papers/10.1080/10643389.2018.1542916
- The paper
- Nzeribe, B. N., Crimi, M., Mededovic Thagard, S., & Holsen, T. M. (2019). Physico-Chemical Processes for the Treatment of Per- And Polyfluoroalkyl Substances (PFAS): A review. Critical Reviews in Environmental Science and Technology. https://doi.org/10.1080/10643389.2018.1542916
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.