Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 194

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257)

Wargocki, Pawel, Wyon, David P.·2007·HVAC&R Research

Abstract

Two independent field intervention experiments were carried out in mechanically ventilated classrooms receiving 100% outdoor air. Outdoor air supply rate and filter condition were manipulated to modify indoor air quality, and the performance of schoolwork was measured.The conditions were established for one week at a time in a blind crossover design with repeated measures on 10- to 12-year-old children in two classes. Seven exercises exemplifying different aspects of schoolwork (numerical or language-based) were performed as part of normal lessons by pupils who also marked visual analogue scales to indicate their environmental perceptions and the intensity of any symptoms. The children indicated that the air was fresher but otherwise perceived little difference when the outdoor air supply rate increased from 3.0 to 8.5 L/s (6.4–18 cfm) per person, while the speed at which they performed two numerical and two language-based tasks improved significantly. A significant effect of ventilation rate was observed in 70% of all the statistical tests for an effect on work rate, but there were no significant effects on errors. The effects were probably due to improved air quality in the classrooms as judged by a sensory panel of adults blind to conditions, as perceived by children, and as indicated by the reduction in the average CO2 concentration from 1300 to 900 ppm, taking this as a marker of reduced bioeffluent concentration. It was not possible to test the effect of replacing a soiled filter with a new one because very little dust had been retained by the “used” filter and because of an incompletely balanced design. The unbalanced design also made it impossible to test for an interaction between filter condition and ventilation rate. These results indicate the importance of improving indoor air quality and ventilation in classrooms.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/10789669.2007.10390950

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 194

Metadata

Authors
Wargocki, P., & Wyon, D. P.
Venue
HVAC&R Research
Published
2007-03
Volume
13
Issue
2
Pages
165-191
ISSN
  • 1078-9669 (ISSN-L)
  • 1938-5587
OpenAlex
W2075702358
Cited by
194
References
3
FWCI
3.31
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257). https://app.cochat.ai/papers/10.1080/10789669.2007.10390950
The paper
Wargocki, P., & Wyon, D. P. (2007). The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257). HVAC&R Research. https://doi.org/10.1080/10789669.2007.10390950

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.