The Effects of Outdoor Air Supply Rate and Supply Air Filter Condition in Classrooms on the Performance of Schoolwork by Children (RP-1257)
The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Two independent field intervention experiments were carried out in mechanically ventilated classrooms receiving 100% outdoor air. Outdoor air supply rate and filter condition were manipulated to modify indoor air quality, and the performance of schoolwork was measured.The conditions were established for one week at a time in a blind crossover design with repeated measures on 10- to 12-year-old children in two classes. Seven exercises exemplifying different aspects of schoolwork (numerical or language-based) were performed as part of normal lessons by pupils who also marked visual analogue scales to indicate their environmental perceptions and the intensity of any symptoms. The children indicated that the air was fresher but otherwise perceived little difference when the outdoor air supply rate increased from 3.0 to 8.5 L/s (6.4–18 cfm) per person, while the speed at which they performed two numerical and two language-based tasks improved significantly. A significant effect of ventilation rate was observed in 70% of all the statistical tests for an effect on work rate, but there were no significant effects on errors. The effects were probably due to improved air quality in the classrooms as judged by a sensory panel of adults blind to conditions, as perceived by children, and as indicated by the reduction in the average CO2 concentration from 1300 to 900 ppm, taking this as a marker of reduced bioeffluent concentration. It was not possible to test the effect of replacing a soiled filter with a new one because very little dust had been retained by the “used” filter and because of an incompletely balanced design. The unbalanced design also made it impossible to test for an interaction between filter condition and ventilation rate. These results indicate the importance of improving indoor air quality and ventilation in classrooms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Error Analysis
Taylor, J. R. (1982) · Medical Entomology and Zoology · Cited by 2,807
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Taylor, J. R., & Thompson, W. (1998) · Physics Today · doi:10.1063/1.882103 · Cited by 2,734
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Cohen, E. R. (1998) · Measurement Science and Technology · doi:10.1088/0957-0233/9/6/022 · Cited by 1,499
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Daisey, J. M., Angell, W. J., & Apte, M. G. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00153.x · Cited by 977 · cited 4×
“Mendell and Heath (2005) cite seven studies, all performed in the last ten years, that indicate that “ventilation rates are substantially below recommended levels in many US and European schools,” the situation being similar in other parts of the world (Daisey et al. 2003; Boxem et al. 2006).”
BackgroundInfluentialSeppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · cited 2×
“Both interventions are well documented to affect indoor air quality (Seppänen et al. 1999; Wargocki et al. 2002b; Clausen 2004) and can be implemented so that the pupils and teachers remain blind to the interventions.”
BackgroundWARGOCKI, P., WYON, D. P., SUNDELL, J., CLAUSEN, G., & FANGER, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 688 · cited 3×
“Additional reproduction, distribution, or transmission in either print or digital form is notpermitted without ASHRAE's prior written permission. office work performance is consequently affected by the rate at which clean outdoor air is supplied when such sources are present (Wargocki et al. 2000).”
BackgroundSelf-citationA 3 min reasoning test based on grammatical transformation
Baddeley, A. D. (1968) · Psychonomic Science · doi:10.3758/bf03331551 · Cited by 649 · cited 1×
“…(5) logical thinking (i.e., grammatical reasoning)—the pupils categorized statements describing the order of the letter pairs AB and BA as True or False (Baddeley 1968), (6) acoustic proofreading—the pupils read a text, marking the inserted errors, while listening to a recorded voice reading it…”
BackgroundWargocki, P., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 507 · cited 1×
“…that other almost universal sources of indoor air pollution (carpet, books, paper, and computers) do have a negative effect on office performance (Wargocki et al. 1999, 2002a; Bakó-Biró et al. 2004) and that Pawel Wargocki and David P. Wyon are with the International Centre for Indoor…”
BackgroundSelf-citationWargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Self-citationWargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390951 · Cited by 364
Self-citationCreating the Productive Workplace: Places to Work Creatively
(2006) · Taylor & Francis eBooks · doi:10.4324/9780203696880 · Cited by 358
Bako-Biro, Z., Wargocki, P., Weschler, C. J., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00218.x · Cited by 180 · cited 2×
“…sources of indoor air pollution (carpet, books, paper, and computers) do have a negative effect on office performance (Wargocki et al. 1999, 2002a; Bakó-Biró et al. 2004) and that Pawel Wargocki and David P. Wyon are with the International Centre for Indoor Environment and Energy, Department of…”
BackgroundSelf-citationFanger, P. O. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00437.x · Cited by 151
Respiratory effects associated with indoor nitrogen dioxide exposure in children
Pilotto, L., Douglas, R., Attewell, R., & Wilson, S. (1997) · International Journal of Epidemiology · doi:10.1093/ije/26.4.788 · Cited by 146 · cited 1×
“Apart from this they cite only one other study showing an effect of any aspect of air quality on children: Pilotto et al. (1997) showed in a cohort study that air pollutants from gas heaters had a negative effect on attendance at school, which was presumed to be due to a negative effect on…”
BackgroundNew Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure
Smedje, G., & Norbäck, D. (2000) · Archives of Environmental Health: An International Journal · doi:10.1080/00039890009603380 · Cited by 139
Wargocki, P., Wyon, D. P., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00304.x · Cited by 136 · cited 4×
“This seems likely considering that for adults the performance of office work improved with outdoor air supply rates up to 30 L/s (64 cfm) per person (Wargocki et al. 2000, 2004).”
BackgroundInfluentialSelf-citationTham, K. W. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00280.x · Cited by 118 · cited 1×
“These findings were validated in field intervention experiments conducted in computerized call centers (Wargocki et al. 2004; Tham 2004), in which call completion time was reduced by up to 9% by poor air quality.”
BackgroundWargocki, P. L., Lagercrantz, L. P., Witterseh, T., Sundell, J., Wyon, D. P., & Fanger, P. O. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01101.x · Cited by 102 · cited 3×
“…that other almost universal sources of indoor air pollution (carpet, books, paper, and computers) do have a negative effect on office performance (Wargocki et al. 1999, 2002a; Bakó-Biró et al. 2004) and that Pawel Wargocki and David P. Wyon are with the International Centre for Indoor…”
BackgroundSelf-citationBerner, M. M. (1993) · Urban Education · doi:10.1177/0042085993028001002 · Cited by 99 · cited 2×
“The reviewers considered that Rosen and Richardson (1999) did not succeed in proving that the 35%–55% reductions in absenteeism that they recorded during periods of ionization of the air in a day care center were clearly different from the 36% reduction observed in a period of no ionization, and they pointed out that…”
BackgroundFederspiel, C. C., Fisk, W. J., Price, P. N., Liu, G., Faulkner, D., Dibartolomeo, D. L., Sullivan, D. P., & Lahiff, M. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00299.x · Cited by 83 · cited 1×
“The finding that mediocre air quality can reduce call center performance is partially supported by the results of a third field experiment, this one performed at much higher outdoor air supply rates (Federspiel et al. 2004).”
ResultRosén, K. G., & Richardson, G. (1999) · The Science of The Total Environment · doi:10.1016/s0048-9697(99)00266-1 · Cited by 80
Korver, W. O. E. (2001) · Elsevier eBooks · doi:10.1016/b978-0-8155-1449-7.50011-6 · Cited by 68
Sensory pollution sources in buildings
Wargocki, P. L. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00277.x · Cited by 63 · cited 2×
“Subjects assessed air quality using four scales: a continuous acceptability scale (Wargocki 2004), an odor intensity scale (Yaglou et al. 1936), and two horizontal VA scales describing the freshness and dryness of classroom air.”
MethodSelf-citationIndoor air quality effects on office work
Wyon, D. P., & Wargocki, P. L. (2006) · Taylor & Francis eBooks · doi:10.4324/9780203696880-25 · Cited by 32
Self-citationThermal comfort and moderate heat stress
Lee, D. H. K. (1975) · Environmental Research · doi:10.1016/0013-9351(75)90054-7 · Cited by 24
Indoor environment in Dutch primary schools and health of the pupils
van Dijken, F., Bronswijk, V. J. A., & Sundell, J. (2005) · Indoor Air · Cited by 23
Ventilation and health in nonindustrial indoor environments
Wargocki, P. L., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P. J., Pickering, A., Seppänen, O., et al. (2001) · Cited by 11
Self-citationVentilation of Dutch schools; an integral approach to improve design
Zeiler, W., Boxem, G., & Zeiler, W. (2008) · TU/e Research Portal · doi:10.4122/1.1000000970 · Cited by 7
Cited by
Ventilation rates in schools and pupils’ performance
Bakó-Biró, Z., Clements-Croome, D. J., Kochhar, N., Awbi, H. B., & Williams, M. J. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.08.018 · Cited by 580
Sadrizadeh, S., Yao, R., Yuan, F., Awbi, H., Bahnfleth, W., Bi, Y., Cao, G., Croitoru, C., de Dear, R., Haghighat, F., et al. (2022) · Journal of Building Engineering · doi:10.1016/j.jobe.2022.104908 · Cited by 375
Self-citationWargocki, P., & Wyon, D. P. (2007) · HVAC&R Research · doi:10.1080/10789669.2007.10390951 · Cited by 364
Self-citationProviding better thermal and air quality conditions in school classrooms would be cost-effective
Wargocki, P., & Wyon, D. P. (2013) · Building and Environment · doi:10.1016/j.buildenv.2012.10.007 · Cited by 309
Self-citationWargocki, P., & Wyon, D. P. (2017) · Building and Environment · doi:10.1016/j.buildenv.2016.11.020 · Cited by 290
Self-citation
Metadata
- Authors
- Wargocki, P., & Wyon, D. P.
- Venue
- HVAC&R Research
- Publisher
- Informa UK Limited
- Published
- 2007-03
- Volume
- 13
- Issue
- 2
- Pages
- 165-191
- ISSN
- 1078-9669 (ISSN-L)
- 1938-5587
- OpenAlex
- W2075702358
- Cited by
- 194
- References
- 30
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.