CoChat

Reliability and Validity of the Lactate Pro 2 Analyzer

Open access
Crotty, Nora May, Boland, Marie, Mahony, Nick, Donne, Bernard, Fleming, Neil · 2021 · Measurement in Physical Education and Exercise Science

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

This study evaluated the reliability of the portable Lactate Pro 2 analyzer (LP2), and its validity compared to a laboratory-based analyzer, YSI 1500 Sport (YSI). Blood samples (n = 258) were collected during 44 graded incremental rowing tests, with data from 17 tests used to quantify load, heart rate, and oxygen consumption at lactate threshold. Inter-LP2 reliability was high with coefficient of variation = 3.3%; Bland Altman 95% limits of agreement varied from ± 0.3 mmol.L−1 for blood lactate (BLa) ≤4.0 mmol.L−1 to −1.6 to +1.4 mmol.L−1 for BLa >8.0 mmol.L−1, with minimal systematic bias. Despite LP2 measurements being ~1.42 times higher than YSI measurements, no significant differences (P > .05) were detected when quantifying load, heart rate, or oxygen consumption data at lactate threshold. The results support using different LP2 devices interchangeably, especially when BLa ≤ 8 mmol.L−1, and using the LP2 to identify training intensities at lactate threshold.

Overview

Integrity signals

Registry

Crossref · 10.1080/1091367x.2020.1865966

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Research works printed but not linked: 5

  1. Buckley J. D., 2003, Journal of Science and Medicine, 6, 408
  2. Ghosh A. K., 2004, Malaysian Journal of Medical Sciences, 11, 24
  3. Goodwin M. L., 2007, Journal of Diabetes, 1, 558
  4. Mc Grath E., 2019, International Journal of Exercise Science, 12, 1334
  5. Rowe G. S., 2016, Gazzetta Medica Italiana Archivio per le Scienze Mediche, 175, 378

Cited by

See all 63

Metadata

Authors
Crotty, N. M., Boland, M., Mahony, N., Donne, B., & Fleming, N.
Affiliations
Trinity College Dublin (IE)
Corresponding author
Crotty, Nora May
Venue
Measurement in Physical Education and Exercise Science
Published
2021-01-25
Volume
25
Issue
3
Pages
202-211
ISSN
  • 1091-367X (ISSN-L)
  • 1532-7841
OpenAlex
W3122543005
Cited by
50
References
19
Citations by year
2026: 8 · 2025: 11 · 2024: 10 · 2023: 15 · 2022: 4 · 2021: 2
FWCI
7.65
Type
journal article
Language
en
Open access
Licence
cc-by-nc-sa
Locations
  • Measurement in Physical Education and Exercise Science (publishedVersion)
  • Trinity's Access to Research Output (TARA) (Trinity College Dublin) (submittedVersion, cc-by-nc-sa)
Funders
Trinity College Dublin
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Physical Education and Training Studies
Keywords
blood lactate measurement, measurement reliability, measurement validity, lactate threshold, oxygen consumption, heart rate, exercise intensity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.