Accuracy of Digital Tympanic, Oral, Axillary, and Rectal Thermometers Compared with Standard Rectal Mercury Thermometers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To compare a number of electronic tympanic, oral, axillary, and rectal measurements with those taken with a standard rectal mercury thermometer. DESIGN: Prospective open study. SETTING: County hospital, Denmark. SUBJECTS: 200 patients. INTERVENTIONS: Each of 200 patients had 6 electronic measurements of body temperature: 3 in the auditory canal using Ivac Core Check 2090A, Diateck 9000, and Genius 3000A, 1 in the axilla using Terumo Digital C202. 1 in the mouth using Terumo Digital C402, and 1 in the rectum using a Terumo Digital C402. These were compared with readings from a standard mercury glass thermometer in the rectum. MAIN OUTCOME MEASURES: Accuracy of electronic thermometry. RESULTS: The rectal electronic measurements were closest to the rectal mercury readings, with a mean (SD) of -0.05 degrees C (0.12), whereas the other measurements gave unacceptable SDs of temperature differences ranging from 0.41 degrees C to 0.53 degrees C. CONCLUSIONS: We conclude that electronic rectal temperature measurements are the most accurate. We do not recommend electronic tympanic, oral, or axillary measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Reliability and validity of the CORE sensor to assess core body temperature during cycling exercise
Verdel, N., Podlogar, T., Ciuha, U., Holmberg, H.-C., Debevec, T., & Supej, M. (2021) · Sensors · doi:10.3390/s21175932 · Cited by 89
Bijur, P. E., Shah, P. D., & Esses, D. (2016) · Emergency Medicine Journal · doi:10.1136/emermed-2015-205122 · Cited by 55
Pecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Jensen 2000 [44] RCT Surgical unit Adult 200 Rectal, mercury-inglass Tympanic, infrared Oral, digital Axillary, digital Rectal, digital”
Khan, S., Saultry, B., Adams, S., Kouzani, A. Z., Decker, K., Digby, R., & Bucknall, T. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.09.012 · Cited by 49
Metadata
- Authors
- Jensen, B. N.
- Venue
- The European Journal of Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2000-10-20
- Volume
- 166
- Issue
- 11
- Pages
- 848-851
- ISSN
- 1102-4151 (ISSN-L)
- OpenAlex
- W2119854585
- Cited by
- 80
- References
- 1
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm, 5429 d)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of Digital Tympanic, Oral, Axillary, and Rectal Thermometers Compared with Standard Rectal Mercury Thermometers. https://app.cochat.ai/papers/10.1080/110241500447218
- The paper
- Jensen, B. N. (2000). Accuracy of Digital Tympanic, Oral, Axillary, and Rectal Thermometers Compared with Standard Rectal Mercury Thermometers. The European Journal of Surgery. https://doi.org/10.1080/110241500447218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.