Machine and deep learning for workflow recognition during surgery
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Recent years have seen tremendous progress in artificial intelligence (AI), such as with the automatic and real-time recognition of objects and activities in videos in the field of computer vision. Due to its increasing digitalization, the operating room (OR) promises to directly benefit from this progress in the form of new assistance tools that can enhance the abilities and performance of surgical teams. Key for such tools is the recognition of the surgical workflow, because efficient assistance by an AI system requires this system to be aware of the surgical context, namely of all activities taking place inside the operating room. We present here how several recent techniques relying on machine and deep learning can be used to analyze the activities taking place during surgery, using videos captured from either endoscopic or ceiling-mounted cameras. We also present two potential clinical applications that we are developing at the University of Strasbourg with our clinical partners.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
British Machine Vision Conference (BMVC)
Damen, D., & Hogg, D. (2007) · Cited by 1,213
EndoNet: A Deep Architecture for Recognition Tasks on Laparoscopic Videos
Twinanda, A. P., Shehata, S., Mutter, D., Marescaux, J., de Mathelin, M., & Padoy, N. (2017) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2593957 · Cited by 1,096 · cited 4×
“This success has been confirmed for recognition in surgical videos as well [9,10,19 – 21].”
BackgroundInfluentialSelf-citationDisruptions in surgical flow and their relationship to surgical errors: An exploratory investigation
Wiegmann, D. A., ElBardissi, A. W., Dearani, J. A., Daly, R. C., & Sundt, T. M. (2007) · Surgery · doi:10.1016/j.surg.2007.07.034 · Cited by 598 · cited 1×
“Disruptions may indeed cause safety issues [31] and a recent study notes that over 129 surgeries observed in the OR, a disruption occurred every 75 seconds [32].”
BackgroundSurgical data science for next-generation interventions
Maier-Hein, L., Vedula, S. S., Speidel, S., Navab, N., Kikinis, R., Park, A., Eisenmann, M., Feussner, H., Forestier, G., Giannarou, S., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0132-7 · Cited by 566
Self-citationSV-RCNet: Workflow Recognition From Surgical Videos Using Recurrent Convolutional Network
Jin, Y., Dou, Q., Chen, H., Yu, L., Qin, J., Fu, C.-W., & Heng, P.-A. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2787657 · Cited by 316
Statistical modeling and recognition of surgical workflow
Padoy, N., Blum, T., Ahmadi, S.-A., Feussner, H., Berger, M.-O., & Navab, N. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.10.001 · Cited by 279 · cited 1×
“Considering the current challenge to collect data from all equipment in the OR, most existing works analyzing the temporal workflow have usually relied on videos [2 – 12] or on data manually derived from videos [13 – 15].”
MethodSelf-citation(2023) · Lecture Notes in Computer Science · doi:10.1007/978-3-031-43999-5 · Cited by 169
Weakly supervised convolutional LSTM approach for tool tracking in laparoscopic videos
Nwoye, C. I., Mutter, D., Marescaux, J., & Padoy, N. (2019) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-019-01958-6 · Cited by 149 · cited 1×
“Recent work also shows that by adding a convolutional LSTM to the pipeline to smooth the peak activation maps over time, a similar weakly-supervised methodology can be employed for tool tracking with promising results 3 [26].”
MethodSelf-citationTwinanda, A. P., Yengera, G., Mutter, D., Marescaux, J., & Padoy, N. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2878055 · Cited by 141 · cited 1×
“In recent work, we have also shown that such a system could integrate a prediction of the remaining surgery duration, for instance to automatically call the next patient and notify the cleaning personnel before the end of the procedure [33].”
BackgroundSelf-citationLalys, F., Riffaud, L., Bouget, D., & Jannin, P. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2181168 · Cited by 121
Monitoring tool usage in surgery videos using boosted convolutional and recurrent neural networks
Hajj, H. A., Lamard, M., Conze, P.-H., Cochener, B., & Quellec, G. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.05.001 · Cited by 105
MVOR: A Multi-view RGB-D Operating Room Dataset for 2D and 3D Human Pose EstimationPreprint
Srivastav, V., Issenhuth, T., Kadkhodamohammadi, A., de Mathelin, M., Gangi, A., & Padoy, N. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1808.08180 · Cited by 103
Self-citationYengera, G., Mutter, D., Marescaux, J., & Padoy, N. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1805.08569 · Cited by 98 · cited 2×
“Building methods that can be trained from few manual annotations and can exploit non-anno-tated data will therefore be necessary [24,38], along with the generation of datasets illustrating the true diversity of the OR.”
MethodSelf-citationWeakly-Supervised Learning for Tool Localization in Laparoscopic Videos
Vardazaryan, A., Mutter, D., Marescaux, J., & Padoy, N. (2018) · Lecture notes in computer science · doi:10.1007/978-3-030-01364-6_19 · Cited by 78
Self-citationA Multi-view RGB-D Approach for Human Pose Estimation in Operating Rooms
Kadkhodamohammadi, A., Gangi, A., de Mathelin, M., & Padoy, N. (2017) · IEEE Winter Conference on Applications of Computer Vision · doi:10.1109/wacv.2017.47 · Cited by 72 · cited 2×
“Our results first show that the OR is a challenging environment for the state-of-the-art methods trained and evaluated on traditional computer vision images, such as in the MPII or MSCOCO datasets [22,28,29].”
BackgroundSelf-citationVolkov, M., Hashimoto, D. A., Rosman, G., Meireles, O. R., & Rus, D. (2017) · 2017 IEEE International Conference on Robotics and Automation (ICRA) · doi:10.1109/icra.2017.7989093 · Cited by 64 · cited 1×
“Considering the current challenge to collect data from all equipment in the OR, most existing works analyzing the temporal workflow have usually relied on videos [2 – 12] or on data manually derived from videos [13 – 15].”
MethodEpisode Classification for the Analysis of Tissue/Instrument Interaction with Multiple Visual Cues
Lo, B. P. L., Darzi, A. W., & Yang, G. (2003) · Lecture notes in computer science · doi:10.1007/978-3-540-39899-8_29 · Cited by 56
Real-time recognition of surgical tasks in eye surgery videos
Quellec, G., Charrière, K., Lamard, M., Droueche, Z., Roux, C., Cochener, B., & Cazuguel, G. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.02.007 · Cited by 54
Yu, T., Mutter, D., Marescaux, J., & Padoy, N. (2018) · arXiv.org · doi:10.48550/arxiv.1812.00033 · Cited by 53 · cited 1×
“Building methods that can be trained from few manual annotations and can exploit non-anno-tated data will therefore be necessary [24,38], along with the generation of datasets illustrating the true diversity of the OR.”
MethodSelf-citationAutomatic feature generation in endoscopic images
Klank, U., Padoy, N., Feußner, H., & Navab, N. (2008) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-008-0223-8 · Cited by 50
Self-citationAutomatic phase prediction from low-level surgical activities
Forestier, G., Riffaud, L., & Jannin, P. (2015) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1195-0 · Cited by 49 · cited 1×
“Considering the current challenge to collect data from all equipment in the OR, most existing works analyzing the temporal workflow have usually relied on videos [2 – 12] or on data manually derived from videos [13 – 15].”
MethodSystem events: readily accessible features for surgical phase detection
Malpani, A., Lea, C., Chen, C. C. G., & Hager, G. D. (2016) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1409-0 · Cited by 48 · cited 1×
“It is however noteworthy that there also exist efforts to recognize activities from the signals of other devices, such as from a surgical robot [16] or from sensors that can be integrated into the OR to capture a person ’ s position [17] or tool/device usage [18].”
BackgroundData-driven spatio-temporal RGBD feature encoding for action recognition in operating rooms
Twinanda, A. P., Alkan, E. O., Gangi, A., de Mathelin, M., & Padoy, N. (2015) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-015-1186-1 · Cited by 45
Self-citationRodas, N. L., Barrera, F., & Padoy, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2560761 · Cited by 35 · cited 1×
“…of such a system, illustrated in Figure 10, that can estimate the 3D exposure at every room location through simulation by exploiting information from the X-ray device and from the 3D locations of the clinicians obtained by processing data coming from a multi-view RGB-D camera system [36,37].”
BackgroundSelf-citationArticulated clinician detection using 3D pictorial structures on RGB-D data
Kadkhodamohammadi, A., Gangi, A., de Mathelin, M., & Padoy, N. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.07.001 · Cited by 33 · cited 2×
“Our results first show that the OR is a challenging environment for the state-of-the-art methods trained and evaluated on traditional computer vision images, such as in the MPII or MSCOCO datasets [22,28,29].”
BackgroundSelf-citationTemporal segmentation of laparoscopic videos into surgical phases
Primus, M. J., Schoeffmann, K., & Böszörményi, L. (2016) · International Workshop on Content-Based Multimedia Indexing (CBMI) · doi:10.1109/cbmi.2016.7500249 · Cited by 30
Video based activity recognition in trauma resuscitation
Chakraborty, I., Elgammal, A., & Burd, R. S. (2013) · 2013 10th IEEE International Conference and Workshops on Automatic Face and Gesture Recognition (FG) · doi:10.1109/fg.2013.6553758 · Cited by 29
Surgical Workflow Monitoring Based on Trajectory Data Mining
Nara, A., Izumi, K., Iseki, H., Suzuki, T., Nambu, K., & Sakurai, Y. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-25655-4_27 · Cited by 25 · cited 1×
“It is however noteworthy that there also exist efforts to recognize activities from the signals of other devices, such as from a surgical robot [16] or from sensors that can be integrated into the OR to capture a person ’ s position [17] or tool/device usage [18].”
BackgroundLearning-based Surgical Workflow Detection from Intra-Operative SignalsPreprint
Stauder, R., Kayis, E., & Navab, N. (2017) · arXiv (Cornell University) · doi:10.48550/arxiv.1706.00587 · Cited by 10 · cited 1×
“It is however noteworthy that there also exist efforts to recognize activities from the signals of other devices, such as from a surgical robot [16] or from sensors that can be integrated into the OR to capture a person ’ s position [17] or tool/device usage [18].”
Background
Cited by
Mascagni, P., Vardazaryan, A., Alapatt, D., Urade, T., Emre, T., Fiorillo, C., Pessaux, P., Mutter, D., Marescaux, J., Costamagna, G., et al. (2022) · Annals of Surgery · doi:10.1097/sla.0000000000004351 · Cited by 335
Self-citationCAI4CAI: The Rise of Contextual Artificial Intelligence in Computer Assisted Interventions
Vercauteren, T., Unberath, M., Padoy, N., & Navab, N. (2020) · Proceedings of the IEEE · doi:10.1109/jproc.2019.2946993 · Cited by 125
“processes though AI, akin to a surgical control tower [137], [138], that can analyze the whole digital information in realtime to provide context-aware support and information within and outside the OR.”
BackgroundSelf-citationDeep Learning in Surgical Workflow Analysis: A Review of Phase and Step Recognition
Demir, K. C., Schieber, H., Weise, T., Roth, D., May, M., Maier, A., & Yang, S. H. (2023) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2023.3311628 · Cited by 90
“Hence, endoscopic videos are captured from inside body cameras, thus, do not provide any information about the operating room [17].”
BackgroundMethodInfluentialLeivaditis, V., Maniatopoulos, A. A., Lausberg, H., Mulita, F., Papatriantafyllou, A., Liolis, E., Beltsios, E., Adamou, A., Kontodimopoulos, N., & Dahm, M. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14082729 · Cited by 76
“• Accelerating learning curves, making LUS a more accessible tool for thoracic surgeons and critical care teams.”
Metadata
- Authors
- Padoy, N.
- Venue
- Minimally Invasive Therapy & Allied Technologies
- Publisher
- Informa UK Limited
- Published
- 2019-03-04
- Volume
- 28
- Issue
- 2
- Pages
- 82-90
- ISSN
- 0961-625X (ISSN-L)
- 1364-5706
- 1365-2931
- OpenAlex
- W2921303908
- Cited by
- 181
- References
- 29
- FWCI
- 16.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.