Sample-to-result molecular diagnostic platforms and their suitability for infectious disease testing in low- and middle-income countries
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: Diagnostics are an essential, undervalued part of the health-care system. For many diseases, molecular diagnostics are the gold standard, but are not easy to implement in Low- and Middle-Income Countries (LMIC). Sample-to-result (S2R) platforms combining all procedures in a closed system could offer a solution. In this paper, we investigated their suitability for implementation in LMIC. AREAS COVERED: A scorecard was used to evaluate different platforms on a range of parameters. Most platforms scored fairly on the platform itself, ease-of-use and test consumables; however, shortcomings were identified in cost, distribution and test panels tailored to LMIC needs. The diagnostic coverage for common infectious diseases was found to have a wider coverage in high-income countries (HIC) than LMIC. A literature study showed that in LMIC, these platforms are mainly used as diagnostic tools or evaluation of diagnostic performance, with a minority assessing the operational characteristics or the clinical utility. In this narrative review, we identified various points for adaptation of S2R platforms to LMIC conditions. EXPERT OPINION: For S2R platforms to be suitable for implementation in LMIC some modifications by the manufacturers could be considered. Furthermore, strengthening health systems and digitalization are vital; as are smaller, cheaper, faster, and sustainable technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Enhanced biofilm detection enables more targeted antimicrobial therapy, reduces the recurrence of infections, and shortens hospital stays, ultimately offsetting the initial expenses.”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [362]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diagnostics for the developing world
Mabey, D., Peeling, R. W., Ustianowski, A., & Perkins, M. D. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro841 · Cited by 1,054
Perry, L., & Malkin, R. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0786-3 · Cited by 232 · cited 1×
“This is a matter that often goes overlooked when S2R platforms are donated and can result in substantial issues as a portion of donated equipment may become inoperative and unusable [59].”
BackgroundHay Burgess, D. C., Wasserman, J., & Dahl, C. A. (2006) · Nature · doi:10.1038/nature05440 · Cited by 139
Bårnes, G. K., Gudina, E. K., Berhane, M., Abdissa, A., Tesfaw, G., Abebe, G., Feruglio, S. L., Caugant, D. A., & Jørgensen, H. J. (2018) · BMC Infectious Diseases · doi:10.1186/s12879-018-3589-4 · Cited by 37 · cited 1×
“Affordability is a major problem in LMIC even if testing with the S2R platform is cost-effective comparing to the standard procedure [51,52].”
Result
Research works printed but not linked: 85
- 10.1016/S0140-6736(21)00673-5 · DOI · Paper page
- 10.1038/ng1002-229 · DOI · Paper page
- 10.1056/NEJMsb1214197 · DOI · Paper page
- 10.1016/S1473-3099(13)70250-0 · DOI · Paper page
- 10.1128/JCM.01137-18 · DOI
- 10.1371/journal.pntd.0007047 · DOI
- 10.1186/s12879-018-2976-1 · DOI · Paper page
- 10.1186/s12985-015-0444-8 · doi:10.1186/s12985-015-0444-8
- 10.1128/microbe.10.103.1 · doi:10.1128/microbe.10.103.1
- 10.2471/BLT.16.187468 · DOI · Paper page
- 10.1016/j.diagmicrobio.2018.06.019 · DOI
- 10.1016/j.cmi.2018.03.044 · DOI
- 10.1080/14737159.2018.1491793 · DOI
- 10.3390/diagnostics13081421 · DOI
- 10.1007/s12291-017-0688-8 · DOI
- 10.1128/jcm.02446-21 · DOI
- 10.1016/j.ijid.2003.03.003 · DOI · Paper page
- 10.1586/14737159.2016.1134325 · DOI
- 10.1038/nbt.3215 · DOI
- 10.1038/s41579-021-00598-5 · DOI
- 10.1080/14737159.2017.1273773 · DOI
- WHO Global TB Programme. Xpert MTB/RIF implementation manual: technical and operational ‘how-to’: practical considerations. preprint.2014 [cited 2023 Jun 13]. Available from: https://www.ncbi.nlm.nih.gov/books/NBK254323/pdf/Bookshelf_NBK254323.pdf
- 10.1183/13993003.00543-2016 · DOI · Paper page
- 10.1371/journal.pone.0215753 · DOI
- 10.9745/GHSP-D-21-00121 · DOI
- 10.1371/journal.pone.0047459 · DOI
- 10.4102/ajlm.v9i2.1017 · doi:10.4102/ajlm.v9i2.1017
- 10.1016/j.diagmicrobio.2018.12.004 · DOI
- 10.1016/j.jmoldx.2020.10.003 · doi:10.1016/j.jmoldx.2020.10.003
- 10.1016/j.diagmicrobio.2019.02.006 · doi:10.1016/j.diagmicrobio.2019.02.006
- 10.1016/j.ttbdis.2020.101387 · doi:10.1016/j.ttbdis.2020.101387
- 10.1186/s12992-022-00823-7 · doi:10.1186/s12992-022-00823-7
- 10.1016/j.hazl.2021.100030 · DOI
- 10.1016/j.scitotenv.2020.144167 · DOI
- 10.1371/journal.pntd.0009967 · DOI
- 10.1371/journal.pone.0215756 · DOI
- 10.11604/pamj.2014.18.277.3906 · DOI
- 10.1038/d41586-020-01265-0 · DOI
- 10.1080/23288604.2018.1441620 · DOI · Paper page
- 10.1371/journal.pone.0256883 · DOI
- 10.1038/d41586-019-00212-y · doi:10.1038/d41586-019-00212-y
- 10.11604/pamj.supp.2019.33.2.17366 · doi:10.11604/pamj.supp.2019.33.2.17366
- 10.1371/journal.pntd.0006135 · doi:10.1371/journal.pntd.0006135
- 10.3201/eid2202.151238 · doi:10.3201/eid2202.151238
- Noble LD, Scott LE, Munir R, et al. Rapid evaluation of the Xpert® Xpress CoV-2 plus and Xpert® xpress CoV-2/Flu/RSV plus tests. Diagnostics (Basel). 2022;13:1–16.
- 10.1186/s12879-021-07003-9 · doi:10.1186/s12879-021-07003-9
- 10.1007/s11686-022-00586-6 · DOI
- 10.1080/22221751.2020.1775133 · DOI
- 10.1016/j.jmoldx.2021.02.010 · doi:10.1016/j.jmoldx.2021.02.010
- 10.1371/journal.pntd.0009343 · doi:10.1371/journal.pntd.0009343
- 10.1038/s41598-020-71833-x · doi:10.1038/s41598-020-71833-x
- 10.1371/journal.pntd.0007749 · DOI
- 10.1128/JCM.00519-13 · doi:10.1128/jcm.00519-13
- 10.1371/journal.pntd.0007027 · DOI
- 10.1371/journal.pntd.0002265 · doi:10.1371/journal.pntd.0002265
- 10.1371/journal.pone.0245731 · doi:10.1371/journal.pone.0245731
- 10.1111/jvh.13002 · doi:10.1111/jvh.13002
- 10.2196/16863 · DOI
- 10.1016/S2468-1253(21)00012-1 · doi:10.1016/s2468-1253(21)00012-1
- 10.1016/j.jviromet.2020.114057 · doi:10.1016/j.jviromet.2020.114057
- 10.1016/j.nmni.2016.10.004 · DOI
- 10.1186/s12936-021-03644-y · DOI
- 10.1128/JCM.00962-19 · DOI
- 10.1016/j.ijid.2020.10.054 · DOI
- 10.1371/journal.pmed.1001980 · DOI
- 10.1186/s12866-019-1566-8 · doi:10.1186/s12866-019-1566-8
- 10.1016/j.mimet.2020.105884 · DOI
- 10.4102/ajlm.v11i1.1809 · doi:10.4102/ajlm.v11i1.1809
- 10.1093/jacamr/dlac139 · DOI
- 10.3390/ijerph191811566 · doi:10.3390/ijerph191811566
- 10.1016/j.ebiom.2023.104568 · doi:10.1016/j.ebiom.2023.104568
- 10.1016/j.ijid.2020.08.020 · DOI
- 10.1128/JCM.02168-20 · DOI
- 10.1099/jmm.0.000231 · DOI
- 10.3934/publichealth.2019.4.502 · DOI
- 10.1155/2021/5527505 · DOI
- 10.1089/bio.2021.0022 · DOI
- 10.3389/fpubh.2022.871567 · DOI
- Scott LE, Hsiao N-Y, Dor G, et al. How South Africa used national cycle threshold (ct) values to continuously monitor SARS-CoV-2 laboratory test quality. Diagnostics (Basel). 2023;13:1–13.
- 10.1186/s12879-021-05857-7 · doi:10.1186/s12879-021-05857-7
- 10.1002/ijgo.12870 · doi:10.1002/ijgo.12870
- 10.1186/s13054-022-04006-z · DOI
- 10.1371/journal.pone.0254389 · DOI
- 10.1016/j.jmoldx.2022.10.001 · doi:10.1016/j.jmoldx.2022.10.001
- 10.1016/j.mimet.2019.105719 · doi:10.1016/j.mimet.2019.105719
Cited by
Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts
Almatroudi, A. (2025) · Biology · doi:10.3390/biology14020165 · Cited by 303
“Evidence-based antimicrobial stewardship programs promote appropriate antimicrobial use and assure conformity with local antibiotic susceptibility patterns [378,379].”
Metadata
- Authors
- Hauner, A., Onwuchekwa, C., & Ariën, K. K.
- Venue
- Expert Review of Molecular Diagnostics
- Publisher
- Informa UK Limited
- Published
- 2024-05-03
- Volume
- 24
- Issue
- 5
- Pages
- 423-438
- ISSN
- 1473-7159
- 1744-8352
- Cited by
- 26
- References
- 4
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.