Asbestos Exposure During Renovation and Demolition of Asbestos-Cement Clad Buildings
The DOI matches its Crossref record.
Abstract
External asbestos cement (AC) claddings become weathered after many years by the gradual loss of cement from exposed surfaces; as a result, loosely bound layers enriched with asbestos fibers are formed. This effect usually appears pronounced with roof cladding but slight with wall cladding. Asbestos fibers on such weathered surfaces may be mixtures of chrysotile with amosite or crocidolite. Renovation and demolition of old AC clad buildings could cause asbestos fiber emission, but this has not been investigated in the past. The exposure of workers to asbestos dust during these operations and precautions to minimize exposure now have been investigated at several building sites. Asbestos dust concentrations during water jet cleaning or painting of weathered AC roofing were approximately 0.1 to 0.2 fibers per milliliter (f/ml.). Limited results suggest that concentrations may be reduced substantially by avoiding abrasion of surfaces. Concentrations during AC roof replacement averaged approximately 0.1 f/mL and were reduced markedly by employing more careful work procedures (e.g., by careful handling of sheets or by wet stacking of sheets). Asbestos dust concentrations during demolition by removal of whole sheets averaged 0.3 to 0.6 f/mL for roofs and less than 0.1 f/mL for walls, reflecting the significant differences in extent of weathering between these elements. Suppression of asbestos emissions from roof sheets by wetting or sealing of weathered surfaces was not predictable because of the occurrence of asbestos fibers in dust trapped under sheet laps. Precautions such as respiratory protection and clothing decontamination are considered to be essential for the demolition of roofing containing amosite or crocidolite by the procedures investigated.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, the literature on the subject proves that even a small scope of work can cause a high concentration of asbestos aerosol.28–30,34,35”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [30]
In the citing paper
“In the case of disassembly works with asbestos-cement products, concentrations of 0.1–0.6 f/ml were recorded, while in the case of incorrect removal of asbestos products using “spray on”, up to 100 f/ml were observed.”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [30]
In the citing paper
“Research leads to conclusions30,33 that exposure to historically high airborne fibre levels, prevailing half a century ago, may still occur today when special work procedures are not strictly applied.”
From Comparison of the effects of use, protection, improper renovation and removal of asbestos products on the example of typical old office buildings in Poland (2023) · cites this paper as [30]
In the citing paper
“Weathering of ACMs has been well documented and may lead to higher asbestos fibre concentrations during asbestos abatement (Brown 1987; Spurny 1989; Obmiński 2020; Ervik et al. 2021).”
From Measurements of airborne asbestos fibres during refurbishing (2023) · cites this paper as Brown 1987
In the citing paper
“ACM roof sheet replacement was on average 0.1 f/cm3 over the full work operation.”
From Measurements of airborne asbestos fibres during refurbishing (2023) · cites this paper as Brown 1987
3 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Abuse of Epidemiology: Automobile Manufacturers Manufacture a Defense to Asbestos Liability
Egilman, D. S., & Billings, M. A. (2005) · International Journal of Occupational and Environmental Health · doi:10.1179/oeh.2005.11.4.360 · Cited by 68
Lange, J., Lange, P. R., Reinhard, T. K., & Thomulka, K. W. (1996) · The Annals of Occupational Hygiene · doi:10.1016/0003-4878(95)00081-x · Cited by 55
On the release of asbestos fibers from weathered and corroded asbestos cement products
Spurny, K. R. (1989) · Environmental Research · doi:10.1016/s0013-9351(89)80089-1 · Cited by 49
Asbestos Exposure among Construction Workers During Demolition of Old Houses in Tehran, Iran
KAKOOEI, H., & NORMOHAMMADI, M. (2014) · Industrial Health · doi:10.2486/indhealth.2012-0118 · Cited by 39
Latif, M. T., Baharudin, N. H., Velayutham, P., Awang, N., Hamdan, H., Mohamad, R., & MOKHTAR, M. B. (2010) · Environmental Monitoring and Assessment · doi:10.1007/s10661-010-1843-3 · Cited by 33
Asbestos exposure during home renovation in New South Wales
Park, E., Yates, D. H., Hyland, R. A., & Johnson, A. (2013) · The Medical Journal of Australia · doi:10.5694/mja12.11802 · Cited by 31
Asbestos in building and its destruction
Obmiński, A. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.118685 · Cited by 28
Current and future risks of asbestos exposure in the Australian community
Gray, C., Carey, R. N., & Reid, A. (2016) · International Journal of Occupational and Environmental Health · doi:10.1080/10773525.2016.1227037 · Cited by 25
Stevulova, N., Estokova, A., Holub, M., Singovszka, E., & Csach, K. (2020) · Applied Sciences · doi:10.3390/app10114048 · Cited by 22
The effectiveness of asbestos stabilizers during abrasion of asbestos-cement sheets
Obmiński, A., & Janeczek, J. (2020) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.118767 · Cited by 19
Frangioudakis, G., Collins, J., Otness, P., Goode, J., Tomley, S., Franklin, P., & Ross, J. (2023) · Sustainability · doi:10.3390/su151512071 · Cited by 19
Comparative characterization of particle emissions from asbestos and non-asbestos cement roof slates
Prasauskas, T., Martuzevičius, D., Krugly, E., Kliučininkas, L., Kireitseu, M., & Axel, Z. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.05.010 · Cited by 16
Mathee, A., von Schirnding, Y. E. R., de Wet, T., & Mokoetle, K. (2000) · International Journal of Environmental Health Research · doi:10.1080/09603120050021137 · Cited by 15
Measurements of airborne asbestos fibres during refurbishing
Ervik, T. K., Hammer, S. E., Skaugset, N. P., & Graff, P. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxad041 · Cited by 14
Peripheral Neurologic Abnormalities among Roofing Workers: Sentinel Case and Clinical Screening
Herbert, R., Gerr, F., Luo, J., Harris-Abbott, D., & Landrigan, P. J. (1995) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1995.9935966 · Cited by 13
Framework for assessment and phytoremediation of asbestos-contaminated sites
Gonneau, C., Miller, K., Mohanty, S. K., Xu, R., Hwang, W., Willenbring, J. K., & Casper, B. B. (2017) · Environmental Science and Pollution Research · doi:10.1007/s11356-017-0177-x · Cited by 11
Zhang, Y., Hong, W., & Kim, Y. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.132032 · Cited by 11
Boelter, F. W., Simmons, C. E., & Hewett, P. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.557936 · Cited by 11
Personal protective equipment for preventing asbestos exposure in workers
Beláčková, L., Verbeek, J. H. A. M., Hoving, J. L., van der Molen, H. F., Gagliardi, D., Curti, S., Hulshof, C. T. J., & Scheepers, P. T. J. (2024) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd015158.pub2 · Cited by 10
Demolition waste contaminated with asbestos
Števulová, N., Eštoková, A., Holub, M., & Singovszká, E. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-824533-0.00002-5 · Cited by 10
Air Pollution during Asbestos Removal
Sąkol, G., & Muszyńska-Graca, M. (2018) · Polish Journal of Environmental Studies · doi:10.15244/pjoes/81616 · Cited by 10
Analyses of PCM Asbestos Air Monitoring Results for a Major Abatement Project
Perkins, J. L., Rose, V. E., & Cleveland, M. S. (1992) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1992.10388012 · Cited by 10
(2007) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mem020 · Cited by 9
Obmiński, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-70631-z · Cited by 9
Cancer risk assessment of exposure to asbestos during old building demolition
Hesari, R. Z. J., Rasoulzadeh, Y., Mohammadian, Y., & Nasirzadeh, N. (2022) · Work · doi:10.3233/wor-211433 · Cited by 8
The natural reduction of threat in selected systems of old buildings containing asbestos
Obmiński, A. (2022) · Scientific Reports · doi:10.1038/s41598-021-04487-y · Cited by 7
Asbestos Presence in 20th Century Buildings
Elizalde, R. R. (2022) · Journal of Engineering and Applied Sciences Technology · doi:10.47363/jeast/2022(4)152 · Cited by 7
A study of fibrous aerosols in the home environment in Sosnowiec, Poland
Pastuszka, J. S., Kabała‐Dzik, A., & К.-У., Х. (1999) · The Science of The Total Environment · doi:10.1016/s0048-9697(99)00062-5 · Cited by 7
Angelini, A., & Silvestri, S. (2021) · NEW SOLUTIONS A Journal of Environmental and Occupational Health Policy · doi:10.1177/10482911211052694 · Cited by 6
Exposure hazards from continuing use and removal of asbestos cement products
Gottesfeld, P. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxad066 · Cited by 6
Synthesis of Ye’elimite from Anthropogenic Waste
Kusiorowski, R., Lipowska, B., & Gerle, A. (2023) · Minerals · doi:10.3390/min13020137 · Cited by 6
Macher, G. Z., Beke, D., & Torma, A. (2023) · Chemical engineering transactions · doi:10.3303/cet23107061 · Cited by 6
Obmiński, A. (2021) · Archives of Civil and Mechanical Engineering · doi:10.1007/s43452-021-00323-2 · Cited by 5
Microscopical Analyses of Asbestos-Cement Pipe and Board
Millette, J. R., Compton, S. P., & DePasquale, C. (2018) · The Microscope · doi:10.59082/tnxt8507 · Cited by 5
War journalism: an occupational exposure
Magnavita, N., Congedo, M. T., Prinzio, R. R. D., & Iuliano, A. (2021) · BMJ Case Reports · doi:10.1136/bcr-2021-245165 · Cited by 5
Obmiński, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-37257-z · Cited by 4
“The results of "faulty works" carried out using "dry" or “DIY” techniques were reported by Brown 30 and others 36,37 .”
Background(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq058 · Cited by 4
Brunetti, G., Delmastro, M., Fonte, R., Moscato, G., Bossi, A., Baiardi, P., Massola, A., & Meloni, F. (2003) · PubMed · Cited by 3
Asbestos hazards in the city of Rome, Italy
Piano, M. D., Palagiano, C., & Rimatori, V. (1989) · Social Science & Medicine · doi:10.1016/0277-9536(89)90058-0 · Cited by 2
Asbestos exposure during home renovation in New South Wales
Johnson, A., & Yates, D. H. (2014) · The Medical Journal of Australia · doi:10.5694/mja13.00263 · Cited by 2
Reports of Asbestos-related Lung Cancer from a Telephone Survey
Natori, Y. (2009) · Haigan · doi:10.2482/haigan.49.69 · Cited by 2
Frank, A. L. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.139129 · Cited by 1
Malignant Pleura Mesothelioma: Clinical Perspectives
Grapatsas, K., Leivaditis, V., Zarogoulidis, P., Dahm, M., Iliadis, I. S., Tsilogianni, Z., Koletsis, E. N., Dimopoulos, E., Vasilikos, I., Rizos, G., et al. (2017) · Oncomedicine · doi:10.7150/oncm.20980 · Cited by 1
Fibers: Their Characteristics and Health Implications
Pastuszka, J. S. (2015) · CRC Press eBooks · doi:10.1201/b19592-9 · Cited by 1
Asbestos Fiber Measurements During Low Dust-Generating Work Processes
Kolarik, B. D., Rørbye, S. C., Olsen, M. N., & Kampmann, K. (2025) · Aerobiology · doi:10.3390/aerobiology3040012 · Cited by 1
Breaking the vicious cycle: asbestos-cement waste management in post-conflict Kosovo
Ahmeti, M., & Sylejmani, M. (2026) · Proceedings of the Institution of Civil Engineers - Waste and Resource Management · doi:10.1680/jwarm.25.00039
Wpływ zewnętrznych źródeł emisji azbestu na powietrze wewnętrzne eksploatowanych budynków
Obmiński, A. (2026) · Ciepłownictwo, Ogrzewnictwo, Wentylacja · doi:10.65545/cow.2026.07-08.04
Marker, B. R. (2012) · Episodes · doi:10.18814/epiiugs/2012/v35i2/005
Proceedings of the Workshop on Transite Decontamination Dismantlement and Recycle/Disposal
Available, N. (1993) · University of North Texas Digital Library (University of North Texas)
嫄댁텞臾� �빐泥� �옉�뾽�떆 諛쒖깮�릺�뒗 �꽍硫댁쓽 �끂異� �룊媛�
理쒖땐怨� (2001) · YUHSpace (Yonsei University Medical Library)
Respiratory findings of construction workers exposed to asbestos dust
Ebihara, I., Hirata, M., Hisanaga, N., Shibata, E., & Sakai, K. (1997) · Elsevier eBooks · doi:10.1016/b978-088415386-3/50007-2
Metadata
- Authors
- BROWN, S. K.
- Affiliations
- Commonwealth Scientific and Industrial Research Organisation (AU)
- Corresponding author
- BROWN, STEPHEN K.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1987-05
- Volume
- 48
- Issue
- 5
- Pages
- 478-486
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2150835037
- Cited by
- 49
- References
- 0
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 2 · 2023: 5 · 2022: 5 · 2021: 3 · 2020: 4 · 2018: 2 · 2017: 2 · 2016: 2 · 2015: 1 · 2013: 2 · 2012: 1
- FWCI
- 1.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Occupational and environmental lung diseases
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Social Sciences › Health › Occupational Health and Global Justice
- Keywords
- asbestos exposure, building renovation, building demolition, chrysotile, amosite, crocidolite, water jet cleaning, roof replacement, respiratory protection, occupational exposure
- MeSH terms
- Asbestos, Construction Materials, Humans, Occupational Diseases
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.