“Worst Case” Aerosol Testing Parameters: I. Sodium Chloride and Dioctyl Phthalate Aerosol Filter Efficiency as a Function of Particle Size and Flow Rate
The DOI matches its Crossref record.
Abstract
The efficiency of filter media is dependent on the characteristics of the challenge aerosol and the filter's construction. Challenge aerosol parameters, such as particle size, density, shape, electrical charge, and flow rate, are influential in determining the filter's efficiency. In this regard, a so-called "worst case" set of conditions has been proposed for testing respirator filter efficiency in order to ensure wearer protection. Data collected on various types of filters (dust and mist; dust, fume, and mist; paint, lacquer, and enamel mist; and high efficiency) challenged with a worst case-type sodium chloride (NaCl) and dioctyl phthalate (DOP) aerosol are presented. The particle size of maximum penetration varies as a function of filter type and was less than 0.25-micron count mean diameter (CMD) in all cases. The count efficiency for high efficiency filters was greater than 99.97% at worst case testing conditions, but the worst case count efficiencies for dust and mist; dust, fume and mist; and paint, lacquer and enamel mist filters were not nearly as efficient as existing test methods indicate. Also, as the test flow rate is increased, the count efficiency decreases. Thus, respirator filters were found to conform to the prediction of single-fiber filtration theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
N95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
MCCULLOUGH, N., BROSSEAU, L., & VESLEY, D. (1997) · The Annals of Occupational Hygiene · doi:10.1016/s0003-4878(97)00022-7 · Cited by 75
Rengasamy, S., Miller, A., & Eimer, B. C. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.515556 · Cited by 54
Brosseau, L. M., McCullough, N. V., & Vesley, D. (1997) · Applied Occupational and Environmental Hygiene · doi:10.1080/1047322x.1997.10389533 · Cited by 43
Metadata
- Authors
- STEVENS, G. A., & MOYER, E. S.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1989-05
- Volume
- 50
- Issue
- 5
- Pages
- 257-264
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W1988509273
- Cited by
- 39
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: “Worst Case” Aerosol Testing Parameters: I. Sodium Chloride and Dioctyl Phthalate Aerosol Filter Efficiency as a Function of Particle Size and Flow Rate. https://app.cochat.ai/papers/10.1080/15298668991374615
- The paper
- STEVENS, G. A., & MOYER, E. S. (1989). “Worst Case” Aerosol Testing Parameters: I. Sodium Chloride and Dioctyl Phthalate Aerosol Filter Efficiency as a Function of Particle Size and Flow Rate. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298668991374615
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.