The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Abstract
In 1995 the National Institute for Occupational Safety and Health issued new regulations for nonpowered particulate respirators (42 CFR Part 84). A new filter certification system also was created. Among the new particulate respirators that have entered the market, the N95 respirator is the most commonly used in industrial and health care environments. The filtration efficiencies of unloaded N95 particulate respirators have been compared with those of dust/mist (DM) and dust/fume/mist (DFM) respirators certified under the former regulations (30 CFR Part 11). Through laboratory tests with NaCl certification aerosols and measurements with particle-size spectrometers, N95 respirators were found to have higher filtration efficiencies than DM and DFM respirators and noncertified surgical masks. N95 respirators made by different companies were found to have different filtration efficiencies for the most penetrating particle size (0.1 to 0.3 micron), but all were at least 95% efficient at that size for NaCl particles. Above the most penetrating particle size the filtration efficiency increases with size; it reaches approximately 99.5% or higher at about 0.75 micron. Tests with bacteria of size and shape similar to Mycobacterium tuberculosis also showed filtration efficiencies of 99.5% or higher. Experimental data were used to calculate the aerosol mass concentrations inside the respirator when worn in representative work environments. The penetrated mass fractions, in the absence of face leakage, ranged from 0.02% for large particle distributions to 1.8% for submicrometer-size welding fumes. Thus, N95 respirators provide excellent protection against airborne particles when there is a good face seal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Inward leakage due to gaps in the fit has been demonstrated to play a critical role in the ability of a mask or respirator to protect against exposure to particulates [4, 59, 82–84].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [83]
In the citing paper
“They have at least 95% filtration efficiency for NaCl particles sized 0.1 to 0.3 𝜇 m with even higher filtration efficiency at higher particle size (approximately 99.5% or higher for 0.75 𝜇 m particles). 5”
From Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density (2020) · cites this paper as [5]
In the citing paper
“with an average aerodynamic diameter reported to range from approximately 0.8-1.1 µm.(14,16,17)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 µm and above.(13,16,24,31,32)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“wearing surgical or FFP2 masks substantially reduces the number of bioaerosol particles emitted from human respiration.”
From Bacteria Filtration Efficiency for Different Types of Protective Face Masks (2023) · cites this paper as [26]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Aerosol penetration and leakae characteristics of masks used in the health care industry
Weber, A. M., Willeke, K., Marchloni, R., Myojo, T., McKay, R. T., Donnelly, J., & Liebhaber, F. B. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90027-2 · Cited by 156
Self-citationChen, S.-K., Vesley, D., Brosseau, L. M., & Vincent, J. H. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)90116-3 · Cited by 124
Penetration of Airborne Microorganisms Through a Surgical Mask and a Dust/Mist Respirator
Willeke, K., Qian, Y., Donnelly, J., Grinshpun, S. A., & Ulevičius, V. (1996) · American Industrial Hygiene Association Journal · doi:10.1080/15428119691014882 · Cited by 84
Self-citationCalibration and performance of an API Aerosizer
Cheng, Y., Barr, E. B., Marshall, I. A., & Mitchell, J. P. (1993) · Journal of Aerosol Science · doi:10.1016/0021-8502(93)90034-7 · Cited by 58
Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger
Johnson, B., Martin, D. D. G. E., & Resnick, I. G. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.6.2184-2186.1994 · Cited by 44
STEVENS, G. A., & Moyer, E. S. (1989) · American Industrial Hygiene Association Journal · doi:10.1080/15298668991374615 · Cited by 41
AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES
Chen, C. C., Lehtimäki, M., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360166 · Cited by 37
Self-citationRESPIRATOR PERFORMANCE RATING TABLE FOR MASK DESIGN
Johnson, A. T., Weiss, R. A., & Grove, C. M. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291359500 · Cited by 37
Dynamic size spectrometry of airborne microorganisms: Laboratory evaluation and calibration
Qian, Y., Willeke, K., Ulevičius, V., Grinshpun, S. A., & Donnelly, J. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00043-x · Cited by 37
Self-citationHan, D., Willeke, K., & Colton, C. E. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012874 · Cited by 29
Self-citation
Cited by
Review of Aerosol Transmission of Influenza A virus
Tellier, R. (2006) · Emerging Infectious Diseases · doi:10.3201/eid1211.060426 · Cited by 803
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
An overview of filtration efficiency through the masks: Mechanisms of the aerosols penetration
Tcharkhtchi, A., Abbasnezhad, N., Zarbini Seydani, M., Zirak, N., Farzaneh, S., & Shirinbayan, M. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.08.002 · Cited by 395
“With lower speeds, the particle residence period is increased by means of filter media; hence the likelihood of collision between particle and filter media is increased dramatically [31].”
InfluentialBałazy, A., Toivola, M., Adhikari, A., Sivasubramani, S. K., Reponen, T., & Grinshpun, S. A. (2006) · American Journal of Infection Control · doi:10.1016/j.ajic.2005.08.018 · Cited by 376
“evaluate the respirator performance directly with biologic particles have been primarily focused on airborne bacteria.(7,11-16) N95 filtering face piece respirators are certified under NIOSH 42 CFR 84 regulations.”
MethodSelf-citationFace masks effectively limit the probability of SARS-CoV-2 transmission
Cheng, Y., Ma, N., Witt, C., Rapp, S., Wild, P. S., Andreae, M. O., Pöschl, U., & Su, H. (2021) · Science · doi:10.1126/science.abg6296 · Cited by 338
Metadata
- Authors
- Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C.
- Affiliations
- University of Cincinnati (US)
- Centers for Disease Control and Prevention (US)
- ORCID
- Grinshpun, Sergey A.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1998-02
- Volume
- 59
- Issue
- 2
- Pages
- 128-132
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2110642136
- Semantic Scholar
- d74dd53b1e298bfe66b53b460e63b1ab5e1a8100
- Cited by
- 298
- References
- 12
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 20 · 2023: 21 · 2022: 34 · 2021: 50 · 2020: 44 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 9 · 2015: 6 · 2014: 7 · 2013: 15 · 2012: 5
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01-OH03244)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- N95 respirators, particulate respirators, filtration efficiency, airborne bacteria, inert particles, Mycobacterium tuberculosis, surgical masks, face seals, welding fumes, submicron particles
- MeSH terms
- Aerosols, Air Microbiology, Air Pollution, Equipment Design, Filtration, Humans, Mycobacterium tuberculosis, Particle Size, Respiratory Protective Devices, United States
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles. https://app.cochat.ai/papers/10.1080/15428119891010389
- The paper
- Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998). Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15428119891010389
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.