FILTER AND LEAK PENETRATION CHARACTERISTICS OF A DUST AND MIST FILTERING FACEPIECE
The DOI matches its Crossref record.
Abstract
The filtering facepiece, also referred to as a disposable respirator, is an extensively used type of respirator without an officially accepted fit testing method. This study describes an aerosol generator and a sampling train, which have been developed for investigating the aerosol penetration characteristics through the filter element and the face seal. Electrostatic attraction and impaction are the two primary filtration mechanisms for micrometer- and supermicrometer-sized aerosols, respectively. Filtration and flow dynamics were found to affect aerosol penetration in distinct ways that allow for the differentiation of the face seal leakage from the filter penetration. The slope of the aerosol size-dependent penetration curve potentially may differentiate the face seal leakage from filter penetration.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“As pointed out by Chen et al. (1990), the effect of particle size on the faceseal penetration may be enhanced for well-fitting respirators; the smaller the leak and the larger the particle size, the greater the effect of impaction in removing particles during their passage through the leak.”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Chen et al. (1990)
In the citing paper
“The investigators reported that both filter and faceseal penetration decreased with increased particle size and this dependence was stronger with higher airflow rates.”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Chen et al. (1990)
In the citing paper
“This also agrees with previous studies and can be explained by greater effect of impaction and interception that occurs at higher air velocities (Chen et al., 1990;Huang et al., 2007).”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Chen et al., 1990
In the citing paper
“Furthermore, our finding agrees with the results reported by Chen et al. (1990), who used fixed leaks (circular tubes varying in diameter) and reported that faceseal penetration decreased with an increase in particle size and breathing rate.”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Chen et al. (1990)
In the citing paper
“However, the slight increase in filter penetra-tion with increased breathing rate was not expected (Table 3) and appears to be opposite to the findings reported by Chen et al. (1990), especially for particles .2lm.”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Chen et al. (1990)
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Still being checked.
Cited by
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
“This supports the results of several previous laboratory studies (Holton and Willeke, 1992; Chen et al., 1990; Chen and Willeke, 1992; Balazy et al., 2006a) as well as our recent field study in agricultural environments (Lee et al., 2005b), which have shown that the size of particles affects their…”
ResultAerosol penetration and leakae characteristics of masks used in the health care industry
Weber, A. M., Willeke, K., Marchloni, R., Myojo, T., McKay, R. T., Donnelly, J., & Liebhaber, F. B. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90027-2 · Cited by 156
Self-citationRespiratory protection against bioaerosols: Literature review and research needs
Rengasamy, A., Zhuang, Z., & BerryAnn, R. (2004) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.04.199 · Cited by 138
Aerosol penetration through surgical masks
Chen, C.-C., & Willeke, K. (1992) · American Journal of Infection Control · doi:10.1016/s0196-6553(05)80143-9 · Cited by 118
Self-citation
Metadata
- Authors
- Chen, C. C., Ruuskanen, J., Pilacinski, W., & Willeke, K.
- Affiliations
- University of Cincinnati (US)
- a Aerosol Research and Respiratory Protection Laboratory, Department of Environmental Health, University of Cincinnati, Cincinnati, OH 45267-0056
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1990-12
- Volume
- 51
- Issue
- 12
- Pages
- 632-639
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2037663485
- Cited by
- 53
- References
- 0
- Citations by year
- 2024: 1 · 2023: 1 · 2022: 4 · 2021: 2 · 2020: 1 · 2019: 1 · 2017: 2 · 2016: 2 · 2015: 1 · 2014: 3 · 2013: 4 · 2012: 4
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01-OH-01301)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- filtering facepiece respirators, aerosol penetration, filter penetration, electrostatic attraction, impaction, aerosol generator, filtration mechanism, respirator fit testing
- MeSH terms
- Aerosols, Dust, Filtration, Humans, Particle Size, Respiratory Protective Devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FILTER AND LEAK PENETRATION CHARACTERISTICS OF A DUST AND MIST FILTERING FACEPIECE. https://app.cochat.ai/papers/10.1080/15298669091370275
- The paper
- Chen, C. C., Ruuskanen, J., Pilacinski, W., & Willeke, K. (1990). FILTER AND LEAK PENETRATION CHARACTERISTICS OF A DUST AND MIST FILTERING FACEPIECE. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298669091370275
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.