AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES
The DOI matches its Crossref record.
Abstract
Air-purifying respirators must be certified following the National Institute for Occupational Safety and Health (NIOSH) filter test criteria (30 CFR 11). The criteria specify a range for the mean particle size and the measure of spread permissible for the test aerosol. The authors' experiments have shown that aerosol penetration as a function of particle size differs considerably among certified respirators of the same type. Filtering facepieces (disposable respirators) and cartridges of the dust-mist, dust-mist-fume, and high-efficiency particulate air type were tested. The respirators were sealed to mannequins in a test chamber. The aerosol concentrations inside and outside the respirator were measured by an aerodynamic particle sizer and a laser aerosol spectrometer over a particle size range of 0.1 to 15 microns. Five flow rates ranging from 5 to 100 L/min were used to study flow dependency. The aerosol penetration through the filters is presented as a function of particle size. Aerosol penetration and pressure drop are combined to express the performance of each filter in terms of "quality factor." Under the same test conditions, the quality factor of one respirator may be as much as 6.6 times more than that of another respirator of the same type. The filter quality factor has a greater aerosol size dependency as airflow and aerosol size increase. In general, cartridges have a larger surface area than filtering facepieces but not necessarily lower filter penetration or higher filter quality.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298
Self-citationFilter Performance of N99 and N95 Facepiece Respirators Against Viruses and Ultrafine Particles
Eninger, R. M., Honda, T., Adhikari, A., Heinonen-Tanski, H., Reponen, T., & Grinshpun, S. A. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men019 · Cited by 165
Penetration of 4.5nm to aerosol particles through fibrous filters
Huang, S.-H., Chen, C.-W., Chang, C.-P., Lai, C.-Y., & Chen, C.-C. (2007) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2007.05.007 · Cited by 108
Self-citationN95 and P100 Respirator Filter Efficiency Under High Constant and Cyclic Flow
Eshbaugh, J. P., Gardner, P. D., Richardson, A. W., & Hofacre, K. C. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802558196 · Cited by 84
“The three ANOVA factors were (1) constant flow, (2) particle size, (3) filter, and their interactions.”
BackgroundPerformance of Respirator Filters Using Quality Factor in Korea.
HAN, D.-H. (2000) · INDUSTRIAL HEALTH · doi:10.2486/indhealth.38.380 · Cited by 25
Metadata
- Authors
- Chen, C. C., Lehtimäki, M., & Willeke, K.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1992-09
- Volume
- 53
- Issue
- 9
- Pages
- 566-574
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2002934600
- Cited by
- 37
- References
- 0
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES. https://app.cochat.ai/papers/10.1080/15298669291360166
- The paper
- Chen, C. C., Lehtimäki, M., & Willeke, K. (1992). AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298669291360166
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.