Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 212

The DOI matches its Crossref record.

EVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIA

Jensen, Paul Arthur, Todd, William F., Davis, Gregg N., Scarpino, Pasquale V.·1992·American Industrial Hygiene Association Journal

Abstract

The need to quantify airborne microorganisms in the commercial microbiology industry (biotechnology) and during evaluations of indoor air quality, infectious disease outbreaks, and agriculture health investigations has shown there is a major technological void in bioaerosol sampling techniques to measure and identify viable and nonviable aerosols. As commercialization of microbiology increases and diversifies, it is increasingly necessary to assess occupational exposure to bioaerosols. Meaningful exposure estimates, by using area or environmental samplers, can only be ensured by the generation of data that are both precise and accurate. The Andersen six-stage viable (microbial) particle sizing sampler (6-STG) and the Ace Glass all-glass impinger-30 (AGI-30) have been suggested as the samplers of choice for the collection of viable microorganisms by the International Aerobiology Symposium and the American Conference of Governmental Industrial Hygienists. Some researchers consider these samplers inconvenient for evaluating industrial bioprocesses and indoor or outdoor environments. Alternative samplers for the collection of bioaerosols are available; however, limited information has been reported on their collection efficiencies. A study of the relative sampling efficiencies of eight bioaerosol samplers has been completed. Eight samplers were individually challenged with a bioaerosol, created with a Collison nebulizer, of either Bacillus subtilis or Escherichia coli. The samplers were evaluated under controlled conditions in a horizontal bioaerosol chamber. During each experimental run, simultaneous samples were collected with a reference AGI-30 to verify the concentration of microorganisms in the chamber from run to run and day to day. The results of this research indicate a wide variation in sample collection efficiency for free bacteria (i.e., mostly single cells of E. coli and B. subtilis, dac≥2µm). The particle concentration in the aerosol chamber, as indicated by the AGI-30 sampler, was 2000±85 colony-forming units per cubic meter (CFU/m3)for E. coli and 1170±400 CFUlm3 for B. subtilis. The collection efficiency of the evaluated AGI-30 relative to the reference AGI-30 was 101% + 4%. The 6-STG oversampled the reference AGI-30 by approximately 7%. However, the Andersen single-stage (1-STG), Mattson-Garvin Slit-to-Agar (STA), and Andersen two-stage (2-STG) samplers undersampled the reference AGI-30 by 7%, 10%, and 33%, respectively. The relative collection efficiencies of the Gelman 47-mm membrane filter (MF), Pool Bioanalysis Italiana surface air system (SAS), and Biotest Reuter centrifugal sampler (RCS) were

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1080/15298669291360319

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 212

Metadata

Authors
Jensen, P. A., Todd, W. F., Davis, G. N., & Scarpino, P. V.
Venue
American Industrial Hygiene Association Journal
Published
1992-10
Volume
53
Issue
10
Pages
660-667
ISSN
0002-8894 (ISSN-L)
OpenAlex
W2005828966
Cited by
212
References
0
FWCI
5.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: EVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIA. https://app.cochat.ai/papers/10.1080/15298669291360319
The paper
Jensen, P. A., Todd, W. F., Davis, G. N., & Scarpino, P. V. (1992). EVALUATION OF EIGHT BIOAEROSOL SAMPLERS CHALLENGED WITH AEROSOLS OF FREE BACTERIA. American Industrial Hygiene Association Journal. https://doi.org/10.1080/15298669291360319

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.