Facial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans
The DOI matches its Crossref record.
Abstract
This study investigated the relationship between facial dimensions and the fit of half-mask respirators using fit factors and selected good facial dimension predictor(s) of fit for designing respirators for Korean workers. Three different brands of half-mask respirators-YS, SG, and 3M-were fit-tested on 112 men and 38 women using TSI Portacount 8020, and fit factors were determined. Before fit-testing, 10 facial dimensions were measured. Data were analyzed by descriptive statistics, Pearson's correlation analysis, and quadratic polynomial regression analysis with log-transformed fit factors (LNFF). However, some of the relationships between LNFF and facial dimensions in brand/gender subgroups were found to be curvilinear rather than linear. Because this result indicated that a multiple polynomial regression model including quadratic terms might be more appropriate than a multiple linear regression, data were also analyzed with a quadratic term by examination of the coefficient of partial correlation. No common facial dimension variables were found to be significant for all nine brand/gender subgroups, but the coefficient of regression for the linear term of the bitragion-menton arc was significant in five of nine brand/gender subgroups including male subjects of all three respirator brands. The 3M mask had the highest coefficient of determination values compared with other brands. Using the quadratic term for the 3M mask, face width (bizygomatic breadth) and nose protrusion were good predictors of half-mask fit. In four of nine brand/gender subgroups, nose protrusion was a good predictor of fit through analysis using a quadratic term. Results indicate that face width, bitragion-menton arc, and nose protrusion should be preferentially considered when designing a half-mask respirator for Korean workers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
New respirator fit test panels representing the current U.S. civilian work force
Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701497538 · Cited by 187
The Role of Fit Testing N95/Ffp2/Ffp3 Masks: A Narrative Review
Regli, A., Sommerfield, A., & von Ungern‐Sternberg, B. S. (2021) · Anaesthesia · doi:10.1111/anae.15261 · Cited by 117
The Effect of Subject Characteristics and Respirator Features on Respirator Fit
Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500391668 · Cited by 93
Metadata
- Authors
- Han, D.-H., & Choi, K.-L.
- Venue
- AIHA Journal
- Publisher
- Informa UK Limited
- Published
- 2003-11
- Volume
- 64
- Issue
- 6
- Pages
- 815-822
- ISSN
- 1542-8117 (ISSN-L)
- OpenAlex
- W2076153289
- Cited by
- 53
- References
- 0
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Facial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans. https://app.cochat.ai/papers/10.1080/15428110308984877
- The paper
- Han, D.-H., & Choi, K.-L. (2003). Facial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans. AIHA Journal. https://doi.org/10.1080/15428110308984877
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.