The Effect of Subject Characteristics and Respirator Features on Respirator Fit
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A recent study was conducted to compare five fit test methods for screening out poor-fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were used to assess the fit test methods by using a simulated workplace protection factor (SWPF) test. The purpose of this companion study was to investigate the effect of subject characteristics (gender and face dimensions) and respirator features on respirator fit. The respirator features studied were design style (folding and cup style) and number of sizes available (one size fits all, two sizes, and three sizes). Thirty-three subjects participated in this study. Each was measured for 12 face dimensions using traditional calipers and tape. From this group, 25 subjects with face size categories 1 to 10 tested each respirator. The SWPF test protocol entailed using the PortaCount Plus to determine a SWPF based on total penetration (face-seal leakage plus filter penetration) while the subject performed six simulated workplace movements. Six tests were conducted for each subject/respirator model combination with redonning between tests. The respirator design style (folding style and cup style) did not have a significant effect on respirator fit in this study. The number of respirator sizes available for a model had significant impact on respirator fit on the panel for cup-style respirators with one and two sizes available. There was no significant difference in the geometric mean fit factor between male and female subjects for 16 of the 18 respirator models. Subsets of one to six face dimensions were found to be significantly correlated with SWPFs (p < 0.05) in 16 of the 33 respirator model/respirator size combinations. Bigonial breadth, face width, face length, and nose protrusion appeared the most in subsets (five or six) of face dimensions and their multiple linear regression coefficients were significantly different from zero (p < 0.05). Lip length was found in only one subset. The use of face length and lip length as the criteria to define the current half-facepiece respirator fit test panel may need to be reconsidered when revising the panel. Based on the findings from this and previous studies, face length and face width are recommended measurements that should be used for defining the panel for half-facepiece respirators.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The N95 is NIOSHapproved with 95% filtration efficiency. 43”
From Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density (2020) · cites this paper as [43]
Citations
Cites
Applied Linear Regression Models
(1997) · Technometrics · doi:10.1080/00401706.1997.10485142 · Cited by 4,615
Head-and-Face Anthropometric Survey of U.S. Respirator Users
Zhuang, Z., & Bradtmiller, B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500324727 · Cited by 195 · cited 2×
“respirator users was recently completed by NIOSH.(17) The LANL full-facepiece panel excluded 15.”
BackgroundSelf-citationFitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119 · cited 1×
“(19) The fit of 18 models of NIOSH-certified, N95 filtering-facepiece respirators was assessed by using a simulated workplace protection factor (SWPF) test.(20)”
MethodSelf-citationOESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83 · cited 1×
“Oestenstad et al.(12) studied the location and shape of faceseal leak sites for a single brand of half-mask respirator worn by 73 subjects, and compared those observations to facial measurements, subject gender, and quantitative fit factor.”
Background(2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471125326 · Cited by 76
Comparison of Five Methods for Fit-Testing N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Zhuang, Z., Campbell, D. L., Jensen, P. A., & Myers, W. R. (2002) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220290107002 · Cited by 70
Self-citationRespirator protection factors: Part I — Development of an anthropometric test panel
HACK, A. L., & McConville, J. T. (1978) · American Industrial Hygiene Association Journal · doi:10.1080/0002889778507897 · Cited by 62 · cited 3×
“(19) The respirator sizes for the corresponding face and lip length were based on recommendations by the Los Alamos National Laboratory.(8)”
BackgroundMethodInfluentialAnthropometry of air force women
(1973) · Applied Ergonomics · doi:10.1016/0003-6870(73)90105-1 · Cited by 56 · cited 2×
“There was no significant difference in the GM SWPF between cup style (25) and folding style (22) for combined data from all number of respirator sizes available (p > 0.”
BackgroundMethodFacial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans
Han, D.-H., & Choi, K.-L. (2003) · AIHA Journal · doi:10.1080/15428110308984877 · Cited by 53 · cited 2×
“Since the correlation coefficients are similar to those reported by Han and Choi,(16) they are not reported in this article.”
BackgroundResultAN ASSESSMENT OF CRITICAL ANTHROPOMETRIC DIMENSIONS FOR PREDICTING THE FIT OF A HALF-MASK RESPIRATOR
Oestenstad, R. K., & Perkins, L. L. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360283 · Cited by 50 · cited 4×
“(10−16) Oestenstad and Perkins(12−14) concluded that mentonsubnasale (lower face) length alone was consistently indicated as being correlated or associated with the fit of each brand of half-facepiece respirator rather than face length and lip length.”
BackgroundInfluential
Research works printed but not linked: 4
- Standards Australia and Standards New Zealand, 1994, S/NZS 1716:1994 Respiratory Protective Devices [Standard].
- European Committee for Standardization, 1989, EN 140 Half-Masks and Quarter-Masks; Requirements, Testing, Marking.
- Oestenstad R. K., 1994, Factors Affecting Respirator Leak Sites and Shapes.
- Zhuang Z., 2004, J. Int. Soc. Respir. Prot, 21, 83
Cited by
Langrish, J. P., Mills, N. L., Chan, J. K., Leseman, D. L., Aitken, R. J., Fokkens, P. H., Cassee, F. R., Li, J., Donaldson, K., Newby, D. E., et al. (2009) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-6-8 · Cited by 237
“Leaks around the facemask will lead to a reduction in the efficacy of particle filtration [37,38] and therefore our predicted exposures during application of the facemask are likely to be an underestimate.”
BackgroundLee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
MethodResultInfluentialFacial Anthropometric Differences among Gender, Ethnicity, and Age Groups
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq007 · Cited by 209
“The panel for halffacepiece respirators is defined by face length and lip length (bicheilion breadth) (Zhuang et al., 2005).”
BackgroundInfluentialSelf-citationNew respirator fit test panels representing the current U.S. civilian work force
Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701497538 · Cited by 187
“The variation of respirator fit in each cell has not been investigated in the past; however, at least one study found that a single size facepiece does not fit the population well.(18)”
BackgroundMethodResultSelf-citationLee, S.-A., Hwang, D.-C., Li, H.-Y., Tsai, C.-F., Chen, C.-W., & Chen, J.-K. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/8572493 · Cited by 134
“The assessment of respiratory protection has frequently been conducted using the heads of mannequins [18] instead of human subjects, disregarding that human factors—such as facial dimensions [19] and breathing patterns and flow [13]—may interfere with protection provided by respirators.”
Background
Metadata
- Authors
- Zhuang, Z., Coffey, C. C., & Ann, R. B.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- ORCID
- Zhuang, Ziqing
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-12
- Volume
- 2
- Issue
- 12
- Pages
- 641-649
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2161978306
- Cited by
- 93
- References
- 19
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 7 · 2023: 7 · 2022: 6 · 2021: 9 · 2020: 5 · 2019: 4 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 5 · 2014: 3 · 2013: 3 · 2012: 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Keywords
- N95 respirators, respirator fit, fit testing, face length, facial width, gender differences, lip length
- MeSH terms
- Adult, Equipment Design, Face, Female, Humans, Male, Materials Testing, Respiratory Protective Devices, Sex Factors, Reproducibility of Results, Workplace
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Effect of Subject Characteristics and Respirator Features on Respirator Fit. https://app.cochat.ai/papers/10.1080/15459620500391668
- The paper
- Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005). The Effect of Subject Characteristics and Respirator Features on Respirator Fit. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620500391668
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.