New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
The fit test panels currently used for respirator research, design, and certification are 25-subject panels developed by Los Alamos National Laboratory (LANL) and are based on data from the 1967 and 1968 anthropometric surveys of U.S. Air Force personnel. Military data do not represent the great diversity in face size and shape seen in civilian populations. In addition, the demographics of the U.S. population have changed over the last 30 years. Thus, it is necessary to assess and refine the LANL fit test panels. This paper presents the development of new respirator fit test panels representative of current U.S. civilian workers based on an anthropometric survey of 3,997 respirator users conducted in 2003. One panel was developed using face length and face width (bivariate approach) and weighting subjects to match the age and race distribution of the U.S. population as determined from the 2000 census. Another panel was developed using the first two principal components obtained from a set of 10 facial dimensions (age and race adjusted). These 10 dimensions are associated with respirator fit and leakage and can predict the remaining face dimensions well. Respirators designed to fit these panels are expected to accommodate more than 95% of the current U.S. civilian workers. Both panels are more representative of the U.S. population than the existing LANL panel and may be appropriate for testing both half-masks and full-face piece respirators. Respirator manufacturers, standards development organizations, and government respirator certification bodies need to select the appropriate fit test panel for their particular needs. The bivariate panel is simpler to use than the principal component analysis (PCA) panel and is most similar to the LANL panel currently used. The inclusion of the eight additional facial measurements allows the PCA panel to provide better criteria for excluding extreme face sizes from being used. Because the boundaries of the two new panels are significantly different from the LANL panel, it may be necessary to develop new respirator sizing systems. A new five-category sizing system is proposed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Based on the bivariate panel described by [95] for facial size distribution, five subjects were of smaller facial sizes, four were of medium facial sizes, and two were larger facial sizes.”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [95]
Citations
Cites
The application of electronic computers to factor analysis
Kaiser, H. F. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000116 · Cited by 12,459
Fundamentals of Biostatistics.
(1969) · Annals of Internal Medicine · doi:10.7326/0003-4819-70-4-873 · Cited by 4,575
Head-and-Face Anthropometric Survey of U.S. Respirator Users
Zhuang, Z., & Bradtmiller, B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500324727 · Cited by 195
Self-citationThe Effect of Subject Characteristics and Respirator Features on Respirator Fit
Zhuang, Z., Coffey, C. C., & Ann, R. B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500391668 · Cited by 93
Self-citationOESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83
Respirator protection factors: Part I — Development of an anthropometric test panel
HACK, A. L., & McConville, J. T. (1978) · American Industrial Hygiene Association Journal · doi:10.1080/0002889778507897 · Cited by 62
The University of Alabama at Birmingham
Bland, K. I. (2002) · Archives of Surgery · doi:10.1001/archsurg.137.10.1095 · Cited by 57
Anthropometry of air force women
(1973) · Applied Ergonomics · doi:10.1016/0003-6870(73)90105-1 · Cited by 56
Facial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans
Han, D.-H., & Choi, K.-L. (2003) · AIHA Journal · doi:10.1080/15428110308984877 · Cited by 53
AN ASSESSMENT OF CRITICAL ANTHROPOMETRIC DIMENSIONS FOR PREDICTING THE FIT OF A HALF-MASK RESPIRATOR
Oestenstad, R. K., & Perkins, L. L. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360283 · Cited by 50
Research works printed but not linked: 6
- Harry G, 1986, A Collation of United States Air Force Anthropometry, by K.W. Kennedy (Technical Report AAMRL-TR-85-062)
- Los Alamos Scientific Laboratory:, 1973, Selection of Respirator Test Panels Representative of U.S. Adult Facial Sizes by A.L. Hack, E.C. Hyatt, B.J. Held, T.O. Moore, C.P. Richards, and J.T. McConville (Report, LA5488)
- Zhuang Z., 2002, J. Int. Soc. Resp. Prot., 19, 42
- Zhuang Z., 2004, J. Int. Soc. Resp. Prot., 21, 83
- U.S. Census Bureau:, 2002, Census 2000 Basics
- Armstrong Laboratory:, 1993, A Multivariate Anthropometric Method for Crew Station Design: Abridged (U) by G.F. Zehner, R.S. Meindl, and J.A. Hudson (Technical Report AL-TR-1992-0164)
Cited by
Grinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
Facial Anthropometric Differences among Gender, Ethnicity, and Age Groups
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq007 · Cited by 209
Self-citationEffectiveness of face masks used to protect Beijing residents against particulate air pollution
Cherrie, J. W., Apsley, A., Cowie, H., Steinle, S., Mueller, W., Lin, C., Horwell, C. J., Sleeuwenhoek, A., & Loh, M. (2018) · Occupational and Environmental Medicine · doi:10.1136/oemed-2017-104765 · Cited by 174
The Role of Fit Testing N95/Ffp2/Ffp3 Masks: A Narrative Review
Regli, A., Sommerfield, A., & von Ungern‐Sternberg, B. S. (2021) · Anaesthesia · doi:10.1111/anae.15261 · Cited by 117
Digital 3-D headforms with facial features representative of the current US workforce
Zhuang, Z., Benson, S. M., & Viscusi, D. J. (2010) · Ergonomics · doi:10.1080/00140130903581656 · Cited by 92
Self-citation
Metadata
- Authors
- Zhuang, Z., Bradtmiller, B., & Shaffer, R. E.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2007-07-23
- Volume
- 4
- Issue
- 9
- Pages
- 647-659
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2129506957
- Cited by
- 187
- References
- 16
- Citations by year
- 2026: 13 · 2025: 11 · 2024: 19 · 2023: 12 · 2022: 10 · 2021: 16 · 2020: 15 · 2019: 7 · 2018: 8 · 2017: 12 · 2016: 5 · 2015: 9 · 2014: 6 · 2013: 9 · 2012: 7
- FWCI
- 23.79
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Social Sciences › Human Factors and Ergonomics › Ergonomics and Musculoskeletal Disorders
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- respirator fit, facial anthropometry, civilian workers, principal component analysis, half-mask respirators, demographics
- MeSH terms
- Anthropometry, Cephalometry, Equipment Design, Face, Female, Humans, Male, National Institute for Occupational Safety and Health, U.S., Respiratory Protective Devices, United States, Occupational Exposure, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force. https://app.cochat.ai/papers/10.1080/15459620701497538
- The paper
- Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007). New Respirator Fit Test Panels Representing the Current U.S. Civilian Work Force. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620701497538
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.