The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Fitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Abstract
Four performance measures were used to evaluate the fitting characteristics of 18 models of N95 filtering-facepiece respirators: (1) the 5th percentile simulated workplace protection factor (SWPF) value, (2) the shift average SWPF value, (3) the h-value, and (4) the assignment error. The effect of fit-testing on the level of protection provided by the respirators was also evaluated. The respirators were tested on a panel of 25 subjects with various face sizes. Simulated workplace protection factor values, determined from six total penetration (face-seal leakage plus filter penetration) tests with re-donning between each test, were used to indicate respirator performance. Five fit-tests were used: Bitrex, saccharin, generated aerosol corrected for filter penetration, PortaCount Plus corrected for filter penetration, and the PortaCount Plus with the N95-Companion accessory. Without fit-testing, the 5th percentile SWPF for all models combined was 2.9 with individual model values ranging from 1.3 to 48.0. Passing a fit-test generally resulted in an increase in protection. In addition, the h-value of each respirator was computed. The h-value has been determined to be the population fraction of individuals who will obtain an adequate level of protection (i.e., SWPF >/=10, which is the expected level of protection for half-facepiece respirators) when a respirator is selected and donned (including a user seal check) in accordance with the manufacturer's instructions without fit-testing. The h-value for all models combined was 0.74 (i.e., 74% of all donnings resulted in an adequate level of protection), with individual model h-values ranging from 0.31 to 0.99. Only three models had h-values above 0.95. Higher SWPF values were achieved by excluding SWPF values determined for test subject/respirator combinations that failed a fit-test. The improvement was greatest for respirator models with lower h-values. Using the concepts of shift average and assignment error to measure respirator performance yielded similar results. The highest level of protection was provided by passing a fit-test with a respirator having good fitting characteristics.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The Quality Factor (QF) is commonly used to compare the performance of materials used to filter particulates under similar experimental conditions [62–81];”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [71]
Citations
Cites
NIOSH guide to industrial respiratory protection.
(1987) · doi:10.26616/nioshpub87116 · Cited by 128
Comparison of Five Methods for Fit-Testing N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Zhuang, Z., Campbell, D. L., Jensen, P. A., & Myers, W. R. (2002) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220290107002 · Cited by 70
Self-citationSimulated Workplace Performance of N95 Respirators
Coffey, C. C., Campbell, D. L., & Zhuang, Z. (1999) · American Industrial Hygiene Association Journal · doi:10.1080/00028899908984481 · Cited by 62
Self-citationCoffey, C. C., Campbell, D. L., Myers, W. R., & Zhuang, Z. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891011036 · Cited by 40
Self-citationASSIGNED PROTECTION FACTORS FOR TWO RESPIRATOR TYPES BASED UPON WORKPLACE PERFORMANCE TESTING
Lenhart, S. W., & Campbell, D. L. (1984) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/28.2.173 · Cited by 39
Self-citationRespiratory Protection as a Function of Respirator Fitting Characteristics and Fit-Test Accuracy
Campbell, D. L., Coffey, C. C., & Lenhart, S. W. (2001) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660108984607 · Cited by 36
Self-citationMcKay, R. T., & Davies, E. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/104732200301269 · Cited by 23
1997 American Industrial Hygiene Conference and Exposition
(1997) · Biomedical Safety & Standards · doi:10.1097/00149078-199704010-00016 · Cited by 14
Research works printed but not linked: 10
- National Institute for Occupational Safety and Health (NIOSH), 1995, Federal Register, 60, 30336
- Centers for Disease Control and Prevention, 1998, MMWR, 47, 1045
- American National Standards Institute (ANSI), 1992, American National Standard for Respiratory Protection (ANSI-Z88.2)
- Industrial Safety Equipment Association, 1996, Use and Selection Guide for Non-Powered Air Purifying Particulate Respirators
- Occupational Safety and Health Administration (OSHA), 1998, Final Rule Federal Register, 63, 1278
- Hyatt E. C., 1976, Respirator Protection Factors (LA-6084-MS)
- Hack A., 1974, Selection of respirator test panels representative of U.S. adult facial sizes (LA-5488)
- U.S. Department of Health and Human Services (DHHS), 1999, Policy Statement: Saccharin Use for Respirator Fit Testing
- Coffey C. C., 1998, J. Int. Soc. Respir. Protect., 16, 25
- American National Standards Institute (ANSI), 2001, American National Standard for Respirator Fit Testing Methods (ANSI/AIHA-Z88.10)
Cited by
Sorted by citations
Items 101–120 of 120
Herman, A., Porter, D. A., Rottach, D. R., & Guha, S. (2021) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166408 · Cited by 2
Okubo, C. V. C., Ribeiro, R. P., Martins, J. T., & Marziale, M. H. P. (2017) · Cogitare Enfermagem · doi:10.5380/ce.v22i3.50115 · Cited by 2
The Respirator Fit Capability Test: Enhancing the Efficacy of Filtering Facepiece Respirators.
Coffey, C. C., & Miller, C. (2019) · PubMed · Cited by 2
Self-citationBessesen, M. T., Rattigan, S. M., Frederick, J., Cummings, D. A. T., Gaydos, C. A., Gibert, C. L., Gorse, G. J., Nyquist, A., Price, C. S., Reich, N. G., et al. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.06.011 · Cited by 2
Disclosure and Fit Capability of the Filtering Facepiece Respirator
Lofgren, D. J. (2017) · NEW SOLUTIONS A Journal of Environmental and Occupational Health Policy · doi:10.1177/1048291117734882 · Cited by 2
Vollmer, B., Bergman, M. S., Boyles, H., Meyers, J., Payne, N. Y., Pollard, J., & Zhuang, Z. (2025) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2025.2540829 · Cited by 1
Self-citationFakherpour, A., Jahangiri, M., & Seif, M. (2022) · Disaster Medicine and Public Health Preparedness · doi:10.1017/dmp.2022.218 · Cited by 1
Barrios, V. H. P. (2019) · Revista del Instituto de investigación de la Facultad de minas metalurgia y ciencias geográficas · doi:10.15381/iigeo.v22i44.17290 · Cited by 1
Respiratory Flow Characterization of Workers in Healthcare Environment
Zhu, J. (2018) · doi:10.33915/etd.7287 · Cited by 1
Wu, A., Li, L., Tan, C., Meng, X., Ma, X., & Li, C. (2021) · Preprints.org · doi:10.20944/preprints202104.0774.v1
Informing the use of N95 respirators by the general public to reduce wildfire smoke exposure
Kelly, K. R. (2020) · ResearchWorks at the University of Washington (University of Washington) · Cited by 1
Penetration through the staple punctures on five N95 respirator models
Medina, D. E. (2014) · Digital Commons - University of South Florida (University of South Florida)
Respiratory Protection for Healthcare Workers: Are N-95 Respirators and Fit Testing Necessary?
Sno, P., Mei, Y., Siu, Y. K., Chiu, C. K., & Matron, E. (2007)
Janssen, L., Luinenburg, M. D., Mullins, H. E., & Nelson, T. J. (2006)
Behrman, A. J., Buchta, W. G., Budnick, L. D., Hodgson, M. J., Raymond, L. W., Russi, M. B., Spillmann, S. J., & Swift, M. D. (2013)
COVID-19 Preventive Measure: A Study on “MASK-A Boon or a Bane”
Amin, R., Dastidar, R. G., & Vaishali, K. (2022) · Interdisciplinary Perspectives on Infectious Diseases · doi:10.1155/2022/2253656
Danyluk, Q., Hon, C., Astrakianakis, G., Bryce, E., Janssen, B., & Yassi, A. (2023) · doi:10.32920/23935236
Eighteen-Year Trends in Respirator Program Compliance: A Nationwide OSHA Enforcement Analysis
Pilgreen, J. (2026) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.164538
Dellagrotta, K., Richards, H., Chang, J., Henderson, T., Kessee, D., Leadon, L., Mathis, J., & Berkheiser, M. L. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2026.2722261
Metadata
- Authors
- Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2004-04
- Volume
- 1
- Issue
- 4
- Pages
- 262-271
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2023424240
- Cited by
- 119
- References
- 8
- Citations by year
- 2026: 2 · 2025: 1 · 2024: 1 · 2023: 5 · 2022: 6 · 2021: 11 · 2020: 11 · 2019: 8 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 6 · 2014: 5 · 2013: 8 · 2012: 4
- FWCI
- 4.98
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Keywords
- N95 respirators, filtering facepiece respirators, respirator fit testing, workplace protection factor, H-value, respirator selection, filter penetration, face size
- MeSH terms
- Adult, Equipment Design, Face, Female, Filtration, Humans, Male, Materials Testing, Respiratory Protective Devices, Sensitivity and Specificity, Occupational Exposure, Workplace
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review