Simulated Workplace Protection Factors for Half-Facepiece Respiratory Protective Devices
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
This study investigates two different methods (random effects model and 5th percentile) for determining the performance of three types of respiratory protective devices (elastomeric N95 respirators, N95 filtering-facepiece respirators, and surgical masks) during a simulated workplace test. This study recalculated the protection level of three types of respiratory protective devices using the random effects model, compared the two methods with each other and the APF of 10 for half-facepiece respirators, and determined the value of each of the fit test protocols in attaining the desired level of simulated workplace protection factor (SWPF). Twenty-five test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020 and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. Each of the six tests produced an SWPF. To determine the level of protection provided by the respiratory protective devices, a 90% lower confidence limit for the simulated workplace protection factor (SWPF(LCL90%)) and the 5th percentile of simulated workplace protection factor were computed. The 5th percentile method values could be up to seven times higher than the SWPF(LCL90%) values. Without fit testing, all half-facepiece N95 respirators had a 5th percentile of 4.6 and an SWPF(LCL90%) value of 2.7. N95 filtering-facepiece respirators as a class had values of 3.3 and 2.0, respectively, whereas N95 elastomeric respirators had values of 7.3 and 4.6, respectively. Surgical masks did not provide any protection, with values of 1.2 and 1.4, respectively. Passing either the Bitrex, saccharin, or Companion fit test resulted in the respirators providing the expected level of protection with 5th percentiles greater than or equal to 10 except when passing the Bitrex test with N95 filtering-facepiece respirators, which resulted in a 5th percentile of only 7.9. No substantial difference was seen between the three fit tests. All of the SWPF(LCL90%) values after passing a fit test were less than 10. The random model method provides a more conservative estimate of the protection provided by a respirator because it takes into account both between- and within-wearer variability.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“N95 FFR are employed as personal protective equipment (PPE) and they provide a high level of protection for filtering facepiece masks that cover only the nose and mouth (as opposed to full and half-face respirators constructed from elastomeric materials) [3, 58–74].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [64]
In the citing paper
“The Quality Factor (QF) is commonly used to compare the performance of materials used to filter particulates under similar experimental conditions [62–81];”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [64]
Citations
Cites
NIOSH guide to industrial respiratory protection.
(1987) · doi:10.26616/nioshpub87116 · Cited by 146
Comparison of Performance of Three Different Types of Respiratory Protection Devices
Lawrence, R. B., Duling, M. G., Calvert, C. A., & Coffey, C. C. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620600829211 · Cited by 127
Self-citationFitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119 · cited 1×
“The estimated level of protection provided to a particular individual can be altered by changes in facial characteristics, weight gain or loss, and so on.(15) Recent workplace protection factor studies indicate that half-facepiece negative-pressure air-purifying respirators do provide a level of protection greater tha…”
BackgroundSelf-citationZhuang, Z., Coffey, C. C., Jensen, P. A., Campbell, D. L., Lawrence, R. B., & Myers, W. R. (2003) · AIHA Journal · doi:10.1080/15428110308984867 · Cited by 53
Self-citationVariability in Respiratory Protection and the Assigned Protection Factor
Nicas, M., & Neuhaus, J. M. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490275821 · Cited by 41
Coffey, C. C., Campbell, D. L., Myers, W. R., & Zhuang, Z. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891011036 · Cited by 40
Self-citationASSIGNED PROTECTION FACTORS FOR TWO RESPIRATOR TYPES BASED UPON WORKPLACE PERFORMANCE TESTING
(1984) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/28.2.173 · Cited by 38
Selection of respirator test panels representative of U.S. adult facial sizes
Lab., N. M. (. L. A. S., Hack, A., Hyatt, E. C., Held, B., Moore, T., Richards, C., & McConville, J. (1973) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/4335046 · Cited by 32
McKay, R. T., & Davies, E. (2000) · Applied Occupational and Environmental Hygiene · doi:10.1080/104732200301269 · Cited by 23
Measuring Performance of a Half-Mask Respirator in a Styrene Environment
Weber, R. A., & Mullins, H. E. (2000) · AIHAJ - American Industrial Hygiene Association · doi:10.1080/15298660008984553 · Cited by 17
Research works printed but not linked: 2
- American Conference of Governmental Industrial Hygienists (ACGIH): 2006. “2006 TLVs and BEIs.”. Cincinnati, Ohio: ACGIH.
- 1992, American National Standard for Respiratory Protection
Cited by
Particle Sizes of Infectious Aerosols: Implications for Infection Control
Fennelly, K. P. (2020) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(20)30323-4 · Cited by 621
Smith, J. D., MacDougall, C. C., Johnstone, J., Copes, R. A., Schwartz, B., & Garber, G. E. (2016) · Canadian Medical Association Journal · doi:10.1503/cmaj.150835 · Cited by 328
Health Effects of Wildfire Smoke in Children and Public Health Tools: A Narrative Review
Holm, S. M., Miller, M. D., & Balmes, J. R. (2021) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-020-00267-4 · Cited by 246
Lee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
BackgroundMethodLee, S.-A., Hwang, D.-C., Li, H.-Y., Tsai, C.-F., Chen, C.-W., & Chen, J.-K. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/8572493 · Cited by 134
Metadata
- Authors
- Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C.
- Affiliations
- Centers for Disease Control and Prevention (US)
- ORCID
- Slaven, James E.
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2007-04-23
- Volume
- 4
- Issue
- 6
- Pages
- 420-431
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W1992317241
- Cited by
- 52
- References
- 12
- Citations by year
- 2026: 3 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 7 · 2020: 8 · 2019: 2 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 2 · 2013: 2 · 2012: 5
- FWCI
- 2.31
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Keywords
- N95 respirators, filtering facepiece respirators, surgical masks, respirator fit testing, random effects models, protection factor, saccharin test, respiratory protection, face size
- MeSH terms
- Adult, Environmental Monitoring, Female, Humans, Male, Middle Aged, Respiratory Protective Devices, Models, Statistical, Occupational Exposure, Workplace, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simulated Workplace Protection Factors for Half-Facepiece Respiratory Protective Devices. https://app.cochat.ai/papers/10.1080/15459620701346925
- The paper
- Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C. (2007). Simulated Workplace Protection Factors for Half-Facepiece Respiratory Protective Devices. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620701346925
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.