This study investigates two different methods (random effects model and 5th percentile) for determining the performance of three types of respiratory protective devices (elastomeric N95 respirators, N95 filtering-facepiece respirators, and surgical masks) during a simulated workplace test. This study recalculated the protection level of three types of respiratory protective devices using the random effects model, compared the two methods with each other and the APF of 10 for half-facepiece respirators, and determined the value of each of the fit test protocols in attaining the desired level of simulated workplace protection factor (SWPF). Twenty-five test subjects with varying face sizes tested 15 models of elastomeric N95 respirators, 15 models of N95 filtering-facepiece respirators, and 6 models of surgical masks. Simulated workplace testing was conducted using a TSI PORTACOUNT Plus model 8020 and consisted of a series of seven exercises. Six simulated workplace tests were performed with redonning of the respirator/mask occurring between each test. Each of the six tests produced an SWPF. To determine the level of protection provided by the respiratory protective devices, a 90% lower confidence limit for the simulated workplace protection factor (SWPF(LCL90%)) and the 5th percentile of simulated workplace protection factor were computed. The 5th percentile method values could be up to seven times higher than the SWPF(LCL90%) values. Without fit testing, all half-facepiece N95 respirators had a 5th percentile of 4.6 and an SWPF(LCL90%) value of 2.7. N95 filtering-facepiece respirators as a class had values of 3.3 and 2.0, respectively, whereas N95 elastomeric respirators had values of 7.3 and 4.6, respectively. Surgical masks did not provide any protection, with values of 1.2 and 1.4, respectively. Passing either the Bitrex, saccharin, or Companion fit test resulted in the respirators providing the expected level of protection with 5th percentiles greater than or equal to 10 except when passing the Bitrex test with N95 filtering-facepiece respirators, which resulted in a 5th percentile of only 7.9. No substantial difference was seen between the three fit tests. All of the SWPF(LCL90%) values after passing a fit test were less than 10. The random model method provides a more conservative estimate of the protection provided by a respirator because it takes into account both between- and within-wearer variability.

Overview

Integrity signals

Registry

Crossref · 10.1080/15459620701346925

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 12 references

Research works printed but not linked: 2

  1. American Conference of Governmental Industrial Hygienists (ACGIH): 2006. “2006 TLVs and BEIs.”. Cincinnati, Ohio: ACGIH.
  2. 1992, American National Standard for Respiratory Protection

Cited by

See all 52

Metadata

Authors
Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C.
Affiliations
Centers for Disease Control and Prevention (US)
Venue
Journal of Occupational and Environmental Hygiene
Published
2007-04-23
Volume
4
Issue
6
Pages
420-431
ISSN
  • 1545-9624 (ISSN-L)
  • 1545-9632
OpenAlex
W1992317241
Cited by
52
References
12
Citations by year
2026: 3 · 2024: 3 · 2023: 3 · 2022: 1 · 2021: 7 · 2020: 8 · 2019: 2 · 2018: 3 · 2017: 2 · 2016: 3 · 2015: 2 · 2013: 2 · 2012: 5
FWCI
2.31
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Occupational and Environmental Hygiene (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
  • Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
Keywords
N95 respirators, filtering facepiece respirators, surgical masks, respirator fit testing, random effects models, protection factor, saccharin test, respiratory protection, face size
MeSH terms
Adult, Environmental Monitoring, Female, Humans, Male, Middle Aged, Respiratory Protective Devices, Models, Statistical, Occupational Exposure, Workplace, Equipment Failure Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simulated Workplace Protection Factors for Half-Facepiece Respiratory Protective Devices. https://app.cochat.ai/papers/10.1080/15459620701346925
The paper
Duling, M. G., Lawrence, R. B., Slaven, J. E., & Coffey, C. C. (2007). Simulated Workplace Protection Factors for Half-Facepiece Respiratory Protective Devices. Journal of Occupational and Environmental Hygiene. https://doi.org/10.1080/15459620701346925

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.